![Promise Technology VTRAK 15200 Скачать руководство пользователя страница 224](http://html.mh-extra.com/html/promise-technology/vtrak-15200/vtrak-15200_user-manual_1617262224.webp)
VTrak 15200 User Manual
216
With a Hot Spare Drive
If the logical drive rebuilds itself using the hot spare:
1.
Replace the failed drive.
2.
Check the automatic rebuild and hot spare policy to be sure your logical
drive(s) recognize(s) the new drive as a hot spare.
Without a Hot Spare Drive
If no hot spare drive is available, the VTrak will not rebuild the logical drive and it
will remain Critical.
When you install a replacement disk drive into the enclosure, the logical drive will
automatically rebuild the information and data on the newly installed disk drive if
Automatic Rebuild option is enabled.
To enable Automatic Rebuild and set Hot Spare Policy, see page 113 for
WebPAM or page 150 for the CLU.
Enclosure Problems
WebPAM displays red circles
in Tree View to identify components that need
attention.
When a red circle appears over a Host in Tree View, click on the Enclosure
icon. The Enclosure screen will display (below).
Important
If your replacement disk drive was formerly part of a different
logical drive, use the CLU to wipe the reserve sector on the
replacement disk drive. See page 140.