VessRAID 1000i Series Product Manual
18
Making Data and Management Connections
You can configure your VessRAID for:
•
Direct Attached Storage (DAS), see below
•
Storage Area Network (SAN), see page 20
•
JBOD Expansion to DAS or SAN (16- and 12-bay models), see page 22
Direct Attached Storage (DAS)
This arrangement requires:
•
A Gigabit Ethernet network interface card (GbE NIC) in the Host PC with
iSCSI support (in hardware or software)
•
A standard network switch
•
A network interface connector on the motherboard or network interface card
(NIC) in the Host PC
Configuring a Data Path
VessRAID subsystems have one RAID controller. The controller has four
Ethernet (RJ45) iSCSI Port connectors.
To establish the data path:
1.
Attach one end of an Ethernet cable to the GbE (iSCSI) NIC in the Host PC.
2.
Attach the other end of the Ethernet cable to one of the four iSCSI ports on
the VessRAID subsystem.
Configuring a Management Path
VessRAID subsystems have one RAID controller. The controller has an Ethernet
(RJ45) Management Port connector that enables you to monitor the VessRAID
over your network using the WebPAM PROe software. VessRAID supports
HTTP, HTTPS, and Telnet protocols.
To establish the management path:
1.
Attach one end of an Ethernet cable to the network connector or standard
NIC in the Host PC.
Attach the other end of the Ethernet cable to one of the ports on the standard
network switch.
2.
Attach one end of an Ethernet cable to one of the ports on the standard
network switch.
Note
VessRAID does not support cascading of multiple RAID
subsystems. Cascading is planned for a future release.
Содержание VessRAID 1720i
Страница 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Страница 16: ...VessRAID 1000i Series Product Manual xvi ...
Страница 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Страница 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Страница 154: ...VessRAID 1000i Series Product Manual 138 ...
Страница 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Страница 226: ...VessRAID 1000i Series Product Manual 210 ...
Страница 260: ...VessRAID 1000i Series Product Manual 244 ...
Страница 292: ...VessRAID 1000i Series Product Manual 276 ...