Chapter 5: RAID Monitoring and Maintenance
81
Array Offline
When a disk drive fails on a non-fault-tolerant array (RAID 0) for any reason, the
Array goes Offline. The array cannot read or write data. All of the data on the
array will be lost unless the failed drive is restored to operation.
A fault-tolerant array (RAID 1, 0+1 and 5) will go Offline if two disk drives fail.
An
Array Offline
icon displays in Tree View and the alarm (if enabled) beeps
quickly to call your attention to the condition.
Figure 81.
An Array in Offline condition highlighted in Tree View (left) and
shown in red in Information View (right).
Your first action is to identify which disk drive has failed. Follow the procedure
described for
Array Critical
above.
When you have identified the failed drive, check its connections and run the
drive manufacturer's diagnostic program in an effort to restore the drive to
operation.
There is no Rebuild function for a non-fault-tolerant array.