5.7  Stroke sensor "Sigma"

Install the sensor according to the chapter "Installation,

electrical".

5–25 V DC, in accordance with Namur or DIN 60947-5-6, potential-free

design.

Data

Value Unit

Nominal voltage *

8 VDC

Power consumption - active surface

uncovered

> 3 mA

Power consumption - active surface cov‐

ered

< 1 mA

Rated switching distance

1.5 mm

* Ri ~ 1 kΩ

Cable colour

Polarity

blue

-

brown

+

5.8  Sound pressure level

Sound pressure level LpA < 70 dB according to EN ISO 20361
at maximum stroke length, maximum stroke rate, maximum back pressure

(water)

5.9  Supplementary information for modified versions

(With identity code specification "Version": "M" - "modified")

Technical data of pumps in the modified version can deviate from those of

the standard pumps. They can be queried by stating the details of the

serial number.
During operation with an automatic stroke length adjustment control

together with a variable speed motor, the stroke rate must not fall below

30 strokes / min. Otherwise technical problems occur, because the

mechanical resistance of the stroke adjustment spindle becomes too high.

The motor data sheets for the modified version are valid. They may

deviate from the standard motor data sheets.

With a modified version, it is absolutely necessary to specify the details of

the serial number requesting and ordering the spare and replacement

parts.

Namur sensor (identity code characteristic

"stroke sensor": 3)

Sound pressure level

Technical data

motor

Spare parts

Technical Data

 

 

 

15

Содержание VAMC

Страница 1: ...2006 42 EC Part no 987096 BA VA 022 08 18 EN Please carefully read these operating instructions before use Do not discard The operator shall be liable for any damage caused by installation or operating errors The latest version of the operating instructions are available on our homepage ...

Страница 2: ...ng to the cor rect operation of the unit or is intended to make your work easier Safety notes Safety notes are identified by pictograms see Safety Chapter These operating instructions conform to current EU regulations applicable at the time of publication Please state identity code and serial number which you can find on the nameplate when you contact us or order spare parts This enables the devic...

Страница 3: ...ent conditions 14 5 5 1 Ambient temperatures 14 5 5 2 Media temperatures 14 5 5 3 Air humidity 14 5 6 Motor data 14 5 7 Stroke sensor Sigma 15 5 8 Sound pressure level 15 5 9 Supplementary information for modified versions 15 6 Dimensional Drawings 16 7 Diagrams for Setting the Capacity 17 8 Wear parts Vario C VAMC 18 8 1 Spare parts kits 18 8 2 Diaphragms 18 9 Declaration of Conformity for Machin...

Страница 4: ...springs Hastelloy C4 Hydraulic connector 0 Standard connection Union nut with hose connection 1 Union nut and PVC insert 2 Union nut and PP insert 3 Union nut and PVDF insert 4 Union nut and stainless steel insert 5 Union nut and PVC tube nozzle 6 Union nut and PP tube nozzle 7 Union nut and PVDF tube nozzle 8 Union nut and stainless steel tube nozzle Design 0 with ProMinent logo standard M Modifi...

Страница 5: ...contained in the operating instructions n Observe the general limitations with regard to viscosity limits chem ical resistance and density see also ProMinent resistance list In the product equipment catalogue or at www prominent com n All other uses or modifications are prohibited n The pump is not intended for the metering of gaseous media and solids n The pump is not intended to meter extremely ...

Страница 6: ...in the relevant work area Electrical technician Electrical technicians are deemed to be people who are able to complete work on electrical systems and recognise and avoid possible dangers independently based on their technical training and experience as well as knowledge of pertinent standards and regulations Electrical technicians should be specifically trained for the working envi ronment in whi...

Страница 7: ...fety data sheets are available and that they are kept up to date as well as for producing an associated hazard assessment for the workstations affected WARNING Danger of electric shock A mains voltage may exist inside the pump housing If the pump housing has been damaged you must disconnect it from the mains immediately It may only be returned to service after an authorised repair CAUTION Warning ...

Страница 8: ...ng protective equipment must be installed for operation n Drive front cover n Motor fan cowling n Motor terminal box cover n Plug Pos 9 in Fig 6 in Chap Repair In the event of an electrical accident disconnect the mains cable from the mains or press the emergency cut off switch fitted on the side of the system If feed chemical escapes also depressurise the hydraulic system around the pump as neces...

Страница 9: ...ng of the pump Take appropriate protective measures before working on the pump e g safety glasses safety gloves Adhere to the material safety data sheet for the feed chemical Drain and flush the liquid end before working on the pump CAUTION Warning of feed chemical spraying around Feed chemical can spray out of the hydraulic compo nents if they are manipulated or opened due to pressure in the liqu...

Страница 10: ...re connector 4 Diaphragm 5 Backplate 6 Slide rod 9 Plug n If necessary take protective measures n Adhere to the material safety data sheet for the feed chemical n Ensure that the system is at atmospheric pressure 1 Empty the liquid end turn the liquid end upside down and allow the feed chemical to run out flush out with a suitable medium flush the liquid end thoroughly when using hazardous feed ch...

Страница 11: ...tch the pump on 15 Set the stroke length to 100 16 Place the dosing head 2 with the screws onto the diaphragm 4 and the backplate 5 the suction connector must be pointing downwards in the pump s subsequent fitting position 17 When the pump is running rotate the liquid end as far to the right until the suction connection 1 is pointing vertically downwards 18 Now disconnect the pump from the power s...

Страница 12: ...uipment this device features the symbol showing a waste bin with a line through it The device must not be disposed of along with domestic waste To return the device use the return and collection systems available and observe the local legal requirements Sign indicating EU collection system Information on disposal 12 ...

Страница 13: ...missible priming pressure suction side m WS bar 10008 10016 07026 07042 7 2 8 07012 07024 04039 04063 6 1 7 All figures refer to water at 20 C The suction lift applies to filled suction line and filled liquid end when installed correctly 5 2 Precision Data Value Unit Reproducibility 2 when installed correctly under constant conditions at least 30 stroke length and water at 20 C 5 3 Shipping weight...

Страница 14: ... 50 C Ambient temperature in operation drive motor 10 45 C 5 5 2 Media temperatures Material version PPE PCB PVT SST Long term temperature C 10 50 10 45 10 50 10 50 Max temperature for 15 min C 100 60 100 120 at max operating pressure at max 2 bar 5 5 3 Air humidity Maximum air humidity 95 rel humidity non condensing 5 6 Motor data The key electrical data for the motor can be found on the nameplat...

Страница 15: ...fied Technical data of pumps in the modified version can deviate from those of the standard pumps They can be queried by stating the details of the serial number During operation with an automatic stroke length adjustment control together with a variable speed motor the stroke rate must not fall below 30 strokes min Otherwise technical problems occur because the mechanical resistance of the stroke...

Страница 16: ..._00_53_72_05 P_VA_0003_SW Fig 3 Dimensional drawing of Vario C Material ver sion A B C D E F Connector PCB 191 142 92 243 226 176 DN10 PPE 191 142 92 243 226 178 DN10 PVT 191 142 95 246 228 180 DN10 SST 190 140 90 241 226 180 DN10 with hose nozzle with insert Dimensional drawing of Vario C Dimensional Drawings 16 ...

Страница 17: ...7026 VAMc 10008 VAMc 10016 Vario FM 063 0 5 10 15 20 25 30 35 40 45 50 Q l h 0 20 40 60 80 100 120 s 55 60 65 VAMc 04063 VAMc 04039 VAMc 07012 VAMc 07024 0 5 10 15 20 25 30 35 40 45 50 Q l h 0 2 4 6 8 10 12 s bar 55 60 65 VAMc 04063 VAMc 04039 VAMc 07012 VAMc 07024 Fig 4 Capacity Q at minimum back pressure dependent on the stroke length s and capacity Q dependent on the back pressure p Diagrams fo...

Страница 18: ...ing set cover rings gaskets ball seat Tab 1 Types 10008 10016 07026 07042 Liquid end Material version Order no FM 042 DN 10 PPE 910753 FM 042 DN 10 PCB 910754 FM 042 DN 10 PVT 1003641 FM 042 DN 10 SST 910751 Tab 2 Types 07012 07024 04039 04063 Liquid end Material version Order no FM 063 DN 10 PPE 910758 FM 063 DN 10 PCB 910759 FM 063 DN 10 PVT 1003642 FM 063 DN 10 SST 910756 8 2 Diaphragms Tab 3 D...

Страница 19: ...proved by us will invalidate this dec laration Tab 4 Extract from the Declaration of Conformity Designation of the product Metering pump Vario C product range Product type VAMc Serial number see nameplate on the device Relevant EC directives EC Machinery Directive 2006 42 EC Compliance with the protection targets of the Low Voltage Directive 2014 35 EU according to Appendix I No 1 5 1 of the Machi...

Страница 20: ...987096 3 en_GB 2012 ProMinent GmbH Im Schuhmachergewann 5 11 69123 Heidelberg Germany Telephone 49 6221 842 0 Fax 49 6221 842 419 Email info prominent com Internet www prominent com ...

Отзывы: