ProMinent ProMinent von Taine 0807 PP Скачать руководство пользователя страница 6

Operating instructions ProMinent

 ®

 von Taine

 ®

 0807 PP/PVDF

Page 6

be observed and kept legible.

2.2  Qualification and training of

operating personnel

The personnel responsible for operation,
maintenance, inspection and assembly
must be adequately qualified. Scope of
responsibility and supervision of the
personnel must be exactly defined by the
plant operator. If the staff does not have
the necessary knowledge, they must be
trained and instructed, which may be
performed by the machine manufacturer
or supplier on behalf of the plant operator.
Moreover, the plant operator of the
operating manual are fully understood by
the personnel.

2.3  Hazards in the event of non-

compliance with safety
instructions

Non-compliance with the safety
instructions may produce a risk to the
personnel as well as to the environment
and the machine and results in a loss of
any right to claim damages.

For example, non-compliance may involve
the following hazards:

F

Failure of important functions of the
machine / plant.

F

Failure of specified procedures of
maintenance and repair.

F

Exposure of people to electrical,
mechanical and chemical hazards.

F

Endangering the environment owing to
hazardous substances being released.

2.4  Compliance with regulations

pertaining of safety work

When operating the pump, the safety
instructions contained in this manual, the
relevant national accident prevention
regulations and any other service and

safety instructions issued by the plant
operator are to be observed.

2.5  Safety instructions relevant for

operation

F

If hot or cold machine components
involve hazards, they must be guarded
against accidental contact.

F

Guards for moving parts (e.g. coupling)
must not be removed from the machine
while in operation.

F

Any leakage of hazardous (e.g.
explosive, toxic, hot) fluids must be
drained away so as to prevent any risk
occurring to persons or the
environment. Statutory regulations are
to be complied with.

F

Hazards resulting from electricity are to
be precluded (see, for examgple, the
VDE Specifications and the bye-laws of
the local power supply utilities).

2.6  Safety instructions relevant for

maintenance, inspection and
assembly work

It shall be the plant operator´s
responsibility to ensure that all
maintenance, inspection and assembly
work is performed by authorized and
qualified personnel who have adequately
familiarized themselves with the subject
matter by studying this manual in detail.

Any work on the machine shall only be
performed when it is at a standstill, it being
imperative that the procedure for shutting
down the machine described in this
manual be followed.
Pumps and pump units which convey
hazardous media must be
decontaminated. On completion of work all
safety and protective facilities must be re-
installed and made operative again.

Prior to restarting the machine, the
instructions listed under ´Initial
commissioning´ are to be observed.

Содержание ProMinent von Taine 0807 PP

Страница 1: ...roMinent von Taine 0807 PP and PVDF von Taine 0807 PP von Taine 0807 PVDF Type o 0807 PP o 0807 PVDF Serial No Please enter type serial number of the pump here Please read the manual instructions comp...

Страница 2: ...entrifugal pump ProMinent von Taine 0807 PP and PVDF ProMinent Dosiertechnik GmbH 2003 ProMinent Dosiertechnik GmbH Im Schuhmachergewann 5 11 69123 Heidelberg Germany info prominent de www prominent d...

Страница 3: ...2 7 Unauthorized alterations and production of spare parts 7 2 8 Unauthorized modes of operation 7 3 Transportation and storage 7 3 1 Transportation 7 3 2 Storage 7 3 3 Ambient conditions required for...

Страница 4: ...echnical data 16 10 Spare parts 17 10 1 Exploded view 17 10 2 Bill of materials von Taine 0807 PP 18 10 3 Bill of materials von Taine 0807 PVDF 18 11 Appendix 19 11 1 Dimensional drawing of von Taine...

Страница 5: ...p is 70 dB A according to DIN EN 12639 noise measurement of liquid pumps and pump units 2 Safety This operating manual gives basic instructions which are to be observed during installation operation a...

Страница 6: ...levant national accident prevention regulations and any other service and safety instructions issued by the plant operator are to be observed 2 5 Safety instructions relevant for operation F If hot or...

Страница 7: ...according to the state of the art 3 2 Storage An eventual storage place must be absolutely dry Make sure that the interior of the pump is protected from pollutants 3 3 Ambient conditions required for...

Страница 8: ...rrespond to the suction and delivery ports All suction and delivery tubes to the pump housing should be free of tensile stress The weight of the tubes must not rest on the housing WARNING Do not insta...

Страница 9: ...he name plate corresponds to the existing power supply F All electrical connections and installations of additional protection devices should be performed by an expert in accordance with the instructi...

Страница 10: ...ed with fluid F Switch on the motor If the pump only delivers for a short period of time and then stops delivering the magnetic clutch has been disengaged Proceed as described in chapter 8 below 6 4 S...

Страница 11: ...ere are no magnetisable metal particles in the working area if you assemble or disassemble the pump When the complete head of the pump is assembled or disassembled magnetic forces can cause serious in...

Страница 12: ...f the pump housing 161 Pull the impeller with the impeller magnet 230 847 1 and the center shaft 211 out of the magnet deviding housing 161 Required tool fork or ring spanner No tools required 3 Take...

Страница 13: ...ter shaft Required tool Lever press No tools required 3 Put the center shaft 211 into the thrust ring 314 2 of the pump housing 161 and fit the o ring 412 1 into the groove of the suction flange 162 T...

Страница 14: ...xially on the center shaft 211 Any other repair than the replacement of worn parts should be done by an expert since inappropriate maintenance work usually results in unnecessary costs If the pump wil...

Страница 15: ...mp can be switched on again Motor is overheating Clogged ventilator cowl Clean the ventilator and the cowl Pump is working but not delivering Gas accumulation in the lines Evacuate the lines Too much...

Страница 16: ...3 Protection class IP 55 IP55 Temperature class F F Further data Maximum temperature of the medium 80 C 95 C Maximum viscosity 20 mPas 20 mPas Maximum ambient temperature 40 C 40 C Maximum density of...

Страница 17: ...Operating instructions ProMinent von Taine 0807 PP PVDF Page 17 10 Spare parts 10 1 Exploded view...

Страница 18: ...021 hexagon head cap screw M6x16 DIN933 inox 904 1 1 PUMA 05 0050 007 threaded pin M6x10 DIN914 45H 914 4 PUMA 00 0090 030 hexagon socket screw M5x12 inox 940 1 PUMA 00 0370 029 feather 5x25x5 10 3 Bi...

Страница 19: ...P PVDF Page 19 Pos Qty Order No Designation Material Qty 914 4 PUMA 00 0090 030 hexagon socket screw M5x12 inox 940 1 PUMA 00 0370 029 feather 5x25x5 Subject to technical alteration 11 Appendix 11 1 D...

Страница 20: ...00 6000 7000 F rderleistung capacity l h F rderh he head mWs 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 Dichte density kg dm Dichte density NPSH 50 70 90 110 130 150 170 190 210 230 250 0 1000 2000 3000 4000...

Страница 21: ...urant nominal 1 1 0 65 A Umgebungstemperatur ambient temperature temp rature ambiante max 40 C Bemessungsfrequenz rated frequency fr quence nominale 50Hz Schaltung connection branchement Bemessungsdre...

Страница 22: ...Operating instructions ProMinent von Taine 0807 PP PVDF Page 22 11 4 EC Declaration of Conformity...

Страница 23: ...Notes...

Страница 24: ...resses et liste des fournisseurs fourniesa par le constructeuer Para informase de las direcciones de los distribuitores dirigirse al fabricante ProMinent Dosiertechnik GmbH Im Schuhmachergewann 5 11 6...

Отзывы: