Technical data / Accessories
Climate
Admissible relative air humidity: 92 %, non condensing.
Load in wet and alternating climate: FW 24 in accordance with DIN 50016.
Enclosure rating and safety class
Contact and moisture protection: IP 65 in accordance with IEC 529,
EN 60529, DIN VDE 0470 Part 1 Safety class 1 - electric mains with earth
Technical data of inputs (contact input, level input)
Voltage at open contacts:
5 V DC
±
0.5 V
Input resistance:
12 k
Ω
±
0.5 k
Ω
Short-circuit current:
0.5 mA
±
0.05 mA
Maximum level for “0” signal:
1.0 V
Maximum level for “1” signal:
3.5 V
Minimum closing time contact input: 20 ms
Response time level input:
2 s
Sound pressure level
Sound pressure level: < 70 dB(A) at a distance of 1 m in accordance
with EN 23741 or EN 23742 at maximum stoke, maximum stroke rate,
maximum back pressure (water)
Shipping weight
Shipping weight:
1.8 kg
Suction lances
Retrofit kits
Suction lance for 200 l drum, tank opening 2“ DIN 570, PPE
1022511
Suction lance for 200 l drum, tank opening 2“ DIN 570, PCB
1022512
Suction lance for tank 5-50 l drum, tank opening d50, PPE
1022645
Suction lance for tank 5-50 l drum, tank opening d50, PCB
1022644
Adjustable suction lance with single-stage level switch, closing in the
event of lack of chemicals.
The delivery scope also includes the parts required for connecting the
pump.
Retrofit kit Ex level CNP
1022099
Retrofit kit level switch CNP*
1022115
* connecting parts given suction lances and tanks provided by the
customer
11
Accessories
BA_CO_016_06_07_4spr.p65
21.06.2007, 12:48 Uhr
27
Содержание CONCEPT PLUS 0215
Страница 15: ...15 ProMinent Konformit tserkl rung BA_CO_016_06_07_4spr p65 21 06 2007 12 48 Uhr 15...
Страница 16: ...16 ProMinent BA_CO_016_06_07_4spr p65 21 06 2007 12 48 Uhr 16...
Страница 29: ...29 ProMinent Conformity declaration BA_CO_016_06_07_4spr p65 21 06 2007 12 48 Uhr 29...
Страница 30: ...30 ProMinent BA_CO_016_06_07_4spr p65 21 06 2007 12 48 Uhr 30...
Страница 43: ...43 ProMinent D claration de conformite BA_CO_016_06_07_4spr p65 21 06 2007 12 49 Uhr 43...
Страница 44: ...44 ProMinent BA_CO_016_06_07_4spr p65 21 06 2007 12 49 Uhr 44...
Страница 57: ...57 ProMinent Declaraci n de conformidad BA_CO_016_06_07_4spr p65 21 06 2007 12 49 Uhr 57...
Страница 58: ...58 ProMinent BA_CO_016_06_07_4spr p65 21 06 2007 12 49 Uhr 58...
Страница 59: ...59 ProMinent BA_CO_016_06_07_4spr p65 21 06 2007 12 49 Uhr 59...