Pump capacity was calculated using water and a metering pump warmed to operating temperature.
With types 1001, 1002 and 1004, the pump capacity can fall to zero at 20% stroke length
and back pressure of > 4 bar.
Precision
Data
Value Unit
Capacity range of the product range
-10 ... +10 % *
Reproducibility
±2 % **
* - with max. stroke length and max. operating pressure for all material versions
** - with constant conditions, minimum back pressure of 1 bar, min. 40 % stroke length, water as
the feed chemical and over short time intervals (5 min)
Viscosity
The liquid ends are suitable for the following viscosity ranges:
Design
Range
Unit
Standard
0 ... 200
mPas
With valve springs
200 ... 500
mPas
Technical data