background image

4

7

6. User's Guide

6.1 Receiver

USER'S GUIDE

1. Install attached two BNC antennas on the antenna jack at the rear panel of the 
    receiver. Incline antennas outwards 45 degree to get the best reception.
2. To get the best reception, install receiver at least 1 metre above the ground. Keep
    transmitter at least 1 meter from receiver antennas and far away from interferential
    sources.
3. Use attached mounting rack to install receiver on EIA standard rack.
4.

5. AF output: Insert one end of the signal cable into AF output jack (8) or (9) at the
    back of the receiver and the other end of the signal cable into amplifier or mixer 
    MIC-IN jack.
6. Turn on power switch (1),  LCD will light and show the group and channel number 
    set at last using time.
7. Press  GP button (2), GP LED (4) will light;  release the GP button, GP LED will 
    extinguish. Press CH button(3), CH LED indicator(5) will light; release the CH
    button, CH LED will extinguish.
8. Group adjust: Press GP button (2) for about 3 seconds, GP number on LCD will 
    flash, frequency will also flash; release GP button(2), now GP button changes to 
    UP function and CH button changes to DOWN function, press GP button to move
    GP UP or CH button to move GP down.
9. Channel  adjust: Press CH button (3)  for about 3  seconds,  CH  number on LCD
    will flash, frequency will also flash; release CH button(3), press GP button to move
    CH UP or CH button to move CH down.
10. After adjusting Group and Channel,  release all buttons, group or channel will
     flash about 3 seconds and then stop, frequency will be locked and saved.
11. Adjust receiver GP and CH to be same as transmitter GP and CH (

, receiver LCD will show AF signal strength, RF signal 

    strength and  RF A or RF B reception.( These information will not show when 
    adjusting GP or CH, transmitter is not turned on, or GP and CH of transmitter is 
    different from receiver.)

Note

:  This system has 16 sets of preset frequencies (from 00 to 0F) which will not 

            interfere each  other.  Users  are  suggested to use these frequencies firstly.
            Choose other frequencies if more frequencies are needed.

Plug one end of the AC power adapter into AC power source with specified voltage 

    and the other end into DC INPUT connector (10) on the back of receiver.

according to 

    the above procedure 7,8,9)

6.2 Handheld Microphone

5. Features

1. UHF PLL synthesized circuit, with 256 selectable frequencies for choice.
2. True diversity receiving mode can effectively avoid drop-outs and dead spots.
    Available distance can be more than 100 metre.
3.

4. Adopt high stable circuit design and spare parts, this device can be operated in 
    a wide range of temperature environment (-10

~+60

). Advanced VCO circuit 

    design to allow performers shout loudly without any broken voice happen. It is the 
    best microphone system for stage performance.
5. Using high sensitivity, wide frequency response dynamic cartridge and advanced
    signal processing circuit to present the real and  natural  voice of  both male and 
    female. It is the top choice for live-performance singers.
6.

7. High performance cartridge. Following is frequency response figure.

With special anti-interference circuit and tone code security to effectively avoid

    interference and eliminate noise.

Numeric LCD is  clear  and  accurate in displaying  receiving  channel, receiving 

    signal level and AF signal strength.

8. International EIA standard half U rack. Metal case. Strong and nice.
9. Pre-programmed 16 groups of frequency to be used simultaneously without any
    interference, including 00,01,02,03,04,05,06,07,08,09,0A,0B,0C,0D,0E,0F.
10. Pre-set two groups of frequencies for choice. One is for USA standard, another
       is for Europe standard. Following is frequency list.

X:1000Hz

Y:-59.3dBV/Pa
Y:-57.1dBm/Pa
D:0.0dB

Y:-84.3dBV/Pa
Y:-82.1dBm/Pa
D:0.0dB
Z:-25.0dB

Microphone Frequency Response   dB Ref.1V/Pa

FEATURES

-50

-60

-70

-80

-90

-100

20

50

100

200

500

1K

2K

5K

10K

20K

0 Deg

0 Deg

180 Deg

180D

 eg

1. Open battery cover then insert battery (pay attention to the positive and negative 
    pole). Close battery cover(please see following illustration for battery installation).
2. Turn on power switch (5), LCD will show group  and channel set  at last using time.
3. Group adjust: Press GP button (3) for about 3 seconds, GP number on LCD will 
    flash; release GP button (3), now GP button changes to UP  function and CH button
    (4) changes to DOWN  function,  press  GP  button  to  move GP UP or CH button
    to move GP down.

Содержание UR-M256LC

Страница 1: ...EM USER S MANUAL WIRELESS MICROPHONE SYSTEM ENGLISH ADD Ningbo Free Trade Zone WestArea Zhejiang P R C TEL 86 574 86860690 0692 9743 9745 FAX 86 574 86860689 E mail promic nbip net Http www promic cn...

Страница 2: ...re transmitterand receiver frequencyis same Check if amplifieror other equipment spower is on Check if the connection between receiverand mixer oramplifier is proper Check microphone batterypower Chec...

Страница 3: ...ightly then pull it out Turn offthe power ifthis equipment willnot be usedfor a longperiod of time afterset up Pull Out AC Plug To reduce the risk of electric shock use only the specified power voltag...

Страница 4: ...t UP 4 CH Channelset button andGP CH adjust DOWN 5 Power Switch 6 Handheld microphonebody Connect the cartridge mesh andbattery compartment 7 Battery Compartment Cover Forsetting battery 8 Open Button...

Страница 5: ...ease allbuttons group orchannel will flash about 3 secondsand then stop frequency will belocked and saved 6 Adjustmicrophone s GP and CH accordingto above procedure3 4 5 to makethe frequency same asre...

Страница 6: ...to ACpower source withspecified voltage and the otherend into DCINPUT connector 10 on the backof receiver according to the above procedure7 8 9 6 2 Handheld Microphone 5 Features 1 UHF PLLsynthesized...

Страница 7: ...88 950 790 250 792 150 804 050 803 150 801 350 799 450 797 650 795 750 793 850 EUROPE STANDARD 6 CH GP 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 A B C D E F 851 050 851 700 852 150 852 950 851 400 852 0...

Отзывы: