3.2  Stuff qualification 

 

Improper handling  can  result  in  considerable  injury  and  damage  to 
equipment.  The  activities  described  in  these  operating  instructions 
may only be carried out by skilled stuff who have the qualifications 
described below. Keep unqualified stuff away from hazardous areas. 
 

For  installation and  starting  of the flow-meter  the  stuff  has  to  be familiar  with  the 
relevant  regulations and directives of the country and must  have the qualification 
required. They must have knowledge on measurement and control technology, have 
to be acquainted with electric circuits, are capable of carrying out the work described 
and  can  independently  recognize  potential  hazards.  Depending  on  the  operation 
conditions of the application they have to have the corresponding knowledge, e.g. 
of aggressive media.. 
 

3.3  Special hazards  

 

Comply with the country-specific regulations (e.g. standards) and 
observe the applicable standards and guidelines for special applica-
tions (e.g. for hazardous media such as acetylene, combustible or 
toxic substances as well as for refrigeration systems and compres-
sors). 
Failure to comply with the relevant regulations can result in serious 
personal injury and damage to property

 

A protection from electrostatic discharge (ESD) is required. The pro-
per use of grounded work surfaces and personal wrist straps is re-
quired  when  working  with  exposed  circuitry  (PCB,  printed  circuit 
boards), in order to prevent static discharge from damaging sensitive 
electronic components. 

There is a danger of death caused by electric current. Upon contact 
with life parts, there is a direct danger of death. Electrical instruments 
may only be installed and connected by skilled electrical personnel. 
Operation using a defective power supply unit (e.g. short circuit from 
the mains voltage to the voltage output) can result in life-threatening 
voltages at the instrument. 

Residual media in dismounted instruments can result in a risk to per-
sonnel, the environment and equipment. Take sufficient precaution-
ary  measures.  Do  not  use  this  instrument  in  safety  or  Emergency 
Stop  devices.  Incorrect  use  of  the  instrument  can  result  in  injury. 
Should  a failure  occur,  aggressive  media  with  extremely  high  tem-
perature and under high pressure or vacuum may be present at the 
instrument. 

Содержание UMU-FD 2

Страница 1: ...edersachsenstra e 4 I D 48465 Sch ttorf I Tel 49 0 5923 90 229 0 I Fax 49 0 5923 90 229 29 E Mail office promesstec com I Internet www promesstec com User manual Configuration module front display UMU...

Страница 2: ...Stuff qualification 7 3 3 Special hazards 7 4 Starting and operation 8 4 1 Before mounting 8 4 2 Assembly Installation Configuration 8 5 Configuration module front display UMU FD 2 8 6 Attaching detac...

Страница 3: ...gible e g due to mechanical damage traceability is no longer ensured The sensors described in the operating instructions are developed and manu factured according to the latest knowledge All component...

Страница 4: ...efore using the device Only qualified persons technicians are allowed to install this device If the device is not used as described in this manual the protective devices of the de vice will be impaire...

Страница 5: ...n If report them immediately 2 2 Packaging Do not remove packaging until just before mounting Keep the packaging as it will provide optimum protection during transport e g change in installation site...

Страница 6: ...are persons who set or operate the pushbuttons or potentiom eters of the product during normal operation and who have been made familiar with the content of this manual Reception and unpacking Unpack...

Страница 7: ...l applica tions e g for hazardous media such as acetylene combustible or toxic substances as well as for refrigeration systems and compres sors Failure to comply with the relevant regulations can resu...

Страница 8: ...d the technician must use tools and instruments that are safe from the point of view of safety Operation in normal mode The operating personnel may only adjust or operate the device if these are insta...

Страница 9: ...Programming access can be blocked by assigning a password The password is stored in the device saved to ensure a high level of protection against unauthorized configuration changes 6 Attaching detachi...

Страница 10: ...nal 7 Electrical data Environmental conditions Operating temperatur 20 C to 60 Storage temperature 20 C to 85 C Relative humidity 95 RH non cond protection class IP20 after installation Installation i...

Страница 11: ...rs and can select the appropriate settings for the respective ap plication There is a scrolling help text for each menu which is automatically shown on the 3rd line of the display The configuration ca...

Страница 12: ...elay energized When the icon flashes with 1 or 2 it means a delay in relay action configurable on off delay The arrow keys indicate that the process value is going up down The circle icon confirms the...

Страница 13: ...messtec com 9 Settings flow chart The display will return to Monitor monitoring mode from any menu if no button is pressed for 1 minute The menus texts with a gray background are only displayed as an...

Страница 14: ...use the original packaging or a suit able package To avoid a damage use for example antistatic plastic film shock absorbent material a marking as highly sensitive measuring instru ment 10 3 Liability...

Страница 15: ...orrect handling of the device you should contact promesstec GmbH directly The installation and connection of the device must be carried out in accordance with the applicable regulations of the respect...

Отзывы: