17
promesstec GmbH
I Niedersachsenstraße 4 I D- 48465 Schüttorf I Tel.:+49 (0)5923/ 90 229 0 I Fax:+49 (0)5923/ 90 229 29
E-Mail: [email protected] I Internet: www.promesstec.com
Display readout below min. / above max. (-1.9.9.9, 9.9.9.9)
Input
Range
Readout
Limit
CURR
VOLT
All
-1.9.9.9
Display readout <-1999
9.9.9.9
Display readout > 9999
LIN. R
All
-1.9.9.9
Display readout <-1999
9.9.9.9
Display readout > 9999
POTM
-
-1.9.9.9
Display readout <-1999
9.9.9.9
Display readout > 9999
Readout at hardware error
Error search
Readout
Cause
Text of Internal communication µC / ADC
HW.ER
Permanent error in ADC
Test of internal CJC sensor
CJ.ER
CJC sensor defect
Checksum test of the configuration in RAM
RA.ER
Error in RAM
Checksum test of the configuration in the EEPROM EE.ER
Error in EEPROM
! Error Indications in the display blink once a second. The help text explains the error.