background image

 

 
 

June 2016 

 

 

T A B L E   O F   C O N T E N T S  

 

1 Introduction ............................................................1 

1.1 Features................................................................1 

2 Setting Up...............................................................2 

2.1 General Inspection..................................................2 
2.2 Install the Batteries ................................................3 
2.3 Adjusting the Tilt Stand ...........................................4 
2.4 Power On ..............................................................4 
2.5 Sleep Mode............................................................4 
2.6 Backlight Control ....................................................5 
2.7 Selecting the Range ................................................5 
2.8 Description ............................................................6 

3 Measurements ....................................................... 12 

3.1 Measuring AC or DC Voltage................................... 12 
3.2 Measuring Resistance ............................................ 13 
3.3 Testing Diodes ..................................................... 13 
3.4 Testing for Continuity ............................................ 14 
3.5 Measuring Capacitance .......................................... 15 
3.6 Measuring Frequency ............................................ 16 
3.7 Measuring Transistor ............................................. 16 
3.8 Measuring Temperature ......................................... 17 
3.9 Measuring DC or AC Current................................... 17 

4 Tools .................................................................... 19 

4.1 Data Hold Mode.................................................... 19 
4.2 Capturing Max. and Min. Values .............................. 19 
4.3 Making Relative Measurements ............................... 20 
4.4 Buzzer Feature ..................................................... 20 

5 Bluetooth Function (PD-351 and PD-352) .................. 22 

5.1 System Requirements of Mobile Devices .................. 22 
5.2 Install the application software ............................... 22 
5.3 How to Connect.................................................... 23 
5.4 User Interface ...................................................... 26 

6 Operations ............................................................ 28

 

Содержание PD-350

Страница 1: ...PD 35x Series PD 350 PD 351 PD 352 Digital Multimeter 0 MI2107...

Страница 2: ...ph The symbol on the equipment means SEE USER S MANUAL In this manual may also appear as a Caution or Warning symbol WARNING AND CAUTION statements may appear in this manual to avoid injury hazard or...

Страница 3: ...he state of the test ends before its use Observe all specified ratings of measurement Remember that voltages higher than 60 V DC or 33 V AC rms are dangereus Use this instrument under the specified en...

Страница 4: ...with safety Descriptive Examples of Over Voltage Categories Cat I Low voltage installations isolated from the mains Cat II Portable domestic installations Cat III Fixed domestic installations Cat IV...

Страница 5: ...esistance 13 3 3 Testing Diodes 13 3 4 Testing for Continuity 14 3 5 Measuring Capacitance 15 3 6 Measuring Frequency 16 3 7 Measuring Transistor 16 3 8 Measuring Temperature 17 3 9 Measuring DC or AC...

Страница 6: ...June 2016 7 Technical Specifications 32 8 Maintenance 36 8 1 Cleaning the multimeter 36 8 2 Replacing the battery 36 8 3 Fuse replacement 37...

Страница 7: ...digit reading achieving higher measurement accuracy than 1 3 2 or 3 3 4 digit counterparts Larger display easier data reading analog bar graph is displayed synchronously Connect simultaneously with t...

Страница 8: ...accessories have been already described in this Manual You can check whether there is any loss of accessories with reference to this description If it is found that there is any accessory lost or dama...

Страница 9: ...onnectors from any circuit under test remove test leads from the input terminals Use only the specified battery type Use the following procedure to install the batteries Ensure that the rotary switch...

Страница 10: ...the rotary switch to any other position except To power OFF the multimeter turn the rotary switch to the position 2 5 Sleep Mode The multimeter automatically enters the sleep mode if the rotary switch...

Страница 11: ...e than 2 seconds The backlight will last for 60 seconds 2 7 Selecting the Range Auto ranging is set as default when the meter is powered on is displayed When auto ranging is enabled press to enter the...

Страница 12: ...Page 6 June 2016 2 8 Description Front panel Figure 1 Front Pannel...

Страница 13: ...sistance measurement Frequency measurement Transistor measurement Temperature measurement DC or AC current measurement up to 600 microamperes DC or AC current measurement up to 600 milliamperes DC or...

Страница 14: ...Select frequency duty cycle Capturing Max and Min Values Backlight Data Hold Relative Measurements Bluetooth PD 352 Display screen Figure 2 Display screen Bluetooth enabled Auto range Maximum reading...

Страница 15: ...cted Battery is low DC AC Measurement display OL is short for overload indicates the reading exceeds the display range Measuring units Analog bar graph Measurement units Sign Description M Mega 1E 06...

Страница 16: ...ce hFE Current Amplification Factor Transistor Input terminals The terminal connections for the different measurement functions of the multimeter are described in the table below WARNING Before starti...

Страница 17: ...6 Page 11 Rotary switch position Input terminals Overload protection 750 VAC 1000 VDC 250 VDC or Equivalent voltage RMS 250 VAC or Equivalent voltage RMS 1 A 250 V fast acting fuse 20 A 250 V fast act...

Страница 18: ...as well as their polarity Negative DC voltages will display a negative sign on the left of the display DC voltage ranges are 60 00 mV 600 0 mV 6 000 V 60 00 V 600 0 V 1000 V AC voltage ranges are 60 0...

Страница 19: ...the black test lead to the terminal and the red test lead to the terminal Probe the test points and read the display Press to enable and cycle through the manual ranges 3 3 Testing Diodes CAUTION To...

Страница 20: ...g for Continuity CAUTION To avoid possible damage to your multimeter or to the equipment under test disconnect the circuit power and discharge all high voltage capacitors before testing for continuity...

Страница 21: ...ion to confirm that the capacitor is fully discharged Capacitance ranges are 40 00 nF 400 0 nF 4 000 uF 40 00 uF 400 0 uF 4000 uF Note For the 4000 uF range the measuring duration should be over 30 se...

Страница 22: ...rent press to cycle through frequency measuring duty cycle measuring and original measuring 3 7 Measuring Transistor WARNING To avoid electrical shock or damage to the instrument do not apply more tha...

Страница 23: ...NG Never attempt an in circuit current measurement where the open circuit potential to earth is greater than 250 V Doing so will cause damage to the multimeter and possible electric shock or personal...

Страница 24: ...circuit with a lower voltage connect the red test lead to the other side with a higher voltage Reversing the leads will produce a negative reading but will not damage the multimeter Select DC or AC m...

Страница 25: ...d Min Values In MAX mode the measured maximum value will be held In MIN mode the measured minimum value will be held Press to cycle between the MAX mode and MIN mode Press for more than 2 seconds to e...

Страница 26: ...measurement should be carried out under a certain range that is this function is only available under the manual range mode Analog bar graph is not displayed Note This function is not available when m...

Страница 27: ...e 2016 Page 21 The buzzer will sound long when the short circuit resistance is less than about 30W during the continuity test When the Bluetooth function is time out the buzzer will sound beep two tim...

Страница 28: ...orks over a range of about 10 meters The work range is much longer in open sided and non occluded wide range environment even up to 20 meters If the Bluetooth function in the multimeter is idle for 10...

Страница 29: ...droid application from a place other than the official website of Google Play on your mobile device go to Settings Security and enable the Unknown sources option 5 3 How to Connect Turn on the multime...

Страница 30: ...ooth function is activated skip this step if not a dialog box similar to figure below will ask whether to turn on Bluetooth Click Yes Figure 4 Now the blueetooh will try to detect the multimeter Click...

Страница 31: ...lect the right one to pair After pairing a confirmation message should appear on screen Figure 6 You can repeat this procedure to connect the mobile device to a second multimeter by clicking on No dev...

Страница 32: ...Page 26 June 2016 5 4 User Interface Figure 7 Figure 8...

Страница 33: ...on DC Direct Current AC Alternating Current RES Measuring Resistance DIO Testing Diodes BEEP Testing for Continuity Display Function CAP Measuring Capacitance Hz Measuring Frequency DUT Measuring Duty...

Страница 34: ...stomized name will be shown If this meter is connected to another device the name is still the default one or the customized name to the connected device Figure 9 Add meter In double view click softke...

Страница 35: ...k the icon on the top right of the screen to turn on voice out Click to turn off In settings menu on your Android device you can set the language specific voice for the spoken text or speech rate etc...

Страница 36: ...ve the displayed data into CSV file Share Share the measurements via the installed sharing apps Clear data Clear the data displayed Setting Sampling Interval Set the sampling interval in the applicati...

Страница 37: ...ge 31 Note In trending graph you can pinch the screen to zoom The Y axis value can be zoomed by gesturing along the up down direction and the X axis time can be zoomed by gesturing along the left righ...

Страница 38: ...0 1 A 0 8 2dig mA 600 0 A 6 000 mA 60 00 mA 600 0 mA 6 000A 0 01 mA 0 8 2dig DC Current A A 20 00 A 1 1 mA 1 2 3dig A 600 0 A 0 1 A 1 3dig mA 600 0 A 6 000 mA 60 00 mA 600 0 mA 6 000 A 0 01 mA 0 8 2d...

Страница 39: ...al Vrms 1 V f 1 kHz 1 2 3dig Duty Cycle4 0 1 99 9 1 kHz 0 1 2 5 3dig 50 C to 400 C 1 C 2 5 3dig Temperature C F 58 F to 752 F 1 F 4 5 5dig 2 When measuring capacitance for the 4000 uF range the measur...

Страница 40: ...30 times second PD 351 PD 352 Bluetooth PD 350 Without Auto ranging True RMS PD 352 PD 350 Diodes Test Measuring Transistor Sleep Mode Continuity Test Low battery indication The is displayed when the...

Страница 41: ...ative Humidity 80 Altitude Operating 3 000 m Non operating 15 000 m Note Equipment specifications are set in these environmental operating conditions Operation outside these specifications are also po...

Страница 42: ...is powered by a 6F22 LR22 or equivalent 9 volt battery When the multimeter displays the the battery must be replaced to maintain proper operation Use the following procedure to replacing the battery 1...

Страница 43: ...instrument In order to replace them you must follow these instructions 1 Remove the holster 2 Unscrew and remove the rear panel using a Phillips suitable screwdriver 3 Remove old fuses and replace the...

Страница 44: ...Francesc Moragas 71 75 08907 L HOSPITALET DE LLOBREGAT Barcelona SPAIN Tel 93 184 77 00 Tel Intl 34 93 184 77 02 Fax 93 338 11 26 Fax Intl 34 93 338 11 26 http www promaxelectronics com e mail promax...

Отзывы: