26
NGM EVO USER GUIDE
8.2
Channels ENCODER on NGMsX Expansion
The NGMsX can use TWO channels ENCODER LINE DRIVE up to 500 Khz for channel.
The encoder (or optical line) must be connected with a shielded cable, to prevents electromagnetic
interference . It's also recommended to have separated cable for each encoder and put far away the
connection by interferences sources (inverters,high voltage cable, AC motors, ecc.).
NGIO is ready to use LINE-DRIVE encoders, also supplies the +5Vdc source voltage. It can't be used with PUSH-
PULL or OPEN-COLLECTOR encoders.
In case of motor-drives encoder simulation, is not necessary to connect the Vdc supply, but only the GND.
8.2.1
Electric characteristics
U.m.
Min
Soglia
Max
On voltage level
Vdc
0
0,8
Off volatge level
Vdc
4
12
R input
Ω
6
Frequency
KHz
500
T0 PNP
Index
On level
Vdc
2,5
2,2
7,7
Off level
Vdc
0
1,5
T0 NPN
Index
On level
Vdc
0
1,4
1
Off level
Vdc
2
7,7
8.2.2
Electric character5vdc output encoder supply
Channel
Min
Max
Output Cuurent
Ch1 J22
4,75 Vdc
5,25 Vdc
100 Ma
Ch2 J23
4,75 Vdc
5,25 Vdc
100 Ma
Содержание NGM EVO
Страница 1: ...www promax it ...
Страница 5: ...5 NGM EVO USER GUIDE 3 NGM EVO Connections UP DOWN FRONT ...
Страница 15: ...15 NGM EVO USER GUIDE 4 7 3 Connections OPEN COLLECTOR J13 J14 J13 J13 J14 ...
Страница 16: ...16 NGM EVO USER GUIDE 4 7 4 Connections LINE DRIVE J13 J14 ...
Страница 27: ...27 NGM EVO USER GUIDE 8 2 3 Example J22 J23 WARNING USE A CABLE WITH SHIELD FOR THE CONNECTIONS ...
Страница 29: ...29 NGM EVO USER GUIDE 9 Dimensions N expansions number NGMIO or NGMsx ...