20
Utility
high
line
Meter
box
X
W
Y
X
W
Y
Transfer
switch
House
circuit
breaker
120V
appliance
120V
appliance
240V
appliance
Generator
X
Y
W
G
240V
4P
-
Receptacle
(c)Operating the generator
.
Turn the house AC breaker off before starting the generator.
Start the generator and warm it up.
Turn the house AC breaker on.
[CAUTION]
Do not start the generator with electrical appliance(s) connected and with
their switches on.
Otherwise the appliance(s) may be damaged by the surge voltage at
starting
.