17
Problem Possible
cause Possible
remedy
None or bad sealing.
Note:
Please do not adjust
sealing time longer than
regular time, it will
reduce the life of Teflon tape
and silicone rubber.
Sealing wire is broken.
Sealing wire is loosen.
Insufficient pressure.
Sealing transformer defective.
Teflon tape or silicone rubber
is damage.
Sealing time and cooling time
is too short.
Sealing pressure is too low.
Replace.
Tighten up a sealing wire.
Pressure bar defective:
replace.
Replace.
Replace.
Adjust to proper sealing
time.
Replace bladder bag.
Lid does not close.
Vacuum valve broken
Limit switch disconnection
Replace
Adjusting