Specifications

TruePower

               200W

                400W

Power

 (W)

                 200W 

                400W

Continuous Power

                 200W

400W

Surge Power

 

                 400W

800W

Output Waveform

                        Modified Sine Wave

AC Output voltage

                   

           115V +/- 10%

AC Output amps

 (up to)

 

                   1.8A

3.6A

DC Input Voltage

                           10V to 15V +/-.5v

DC Input Amps

 (up to)

                    20A                              40A

Efficiency

    

                  >85%

No load current

                 <0.3A                             <0.6A

Cooling Fan

   

                    No

                     Yes

Short Protection

                    Yes

  Yes

Soft- Start

                                       Yes

High Voltage Protection

                                       Yes

Low Battery Alarm

 (Bat’ Saver)

                                   11.9VDC

Low Battery Shutdown

 (Bat’ Saver)

                                   11.7VDC

Low battery Alarm

                         10.5VDC +/- .5VDC

Low Battery Shutdown

                          10VDC +/- .5VDC

Reverse Polarity Protection

 (By Fuse)

                    Yes

Operating environment temperature

      -15 to 50

°

 Celsius or 5 to 122

°

 Fahrenheit

External Fuse

                    25A                               40A

Recommended User Supplied

 

                    25A                               40A

ABYC E-11 Compliant Fuse

ProMariner Part No. for Recommended
User Supplied ABYC E-11 Compliant Fuse

Amperage

5 - 70 amps                     30 amp                      40 amp

            AGU Fuses for TruePower Models

88103                             88530                        88540

Single Position

AGU Fuse Holder

AGU Fuse

for 400w

AGU Fuse

for 200w

Inverter Features

The TruePower inverter comes standard with a Ground Fault Circuit Interrupter
(GFCI) protected Dual AC outlet which can protect the user against hazardous
electrical shock that could be caused by dampness, water spray, or worn cables.

Bat’ Saver

- mode allows the user to protect from draining down the entire power of

the engine start battery, and shuts the inverter off when the battery reaches a threshold
of 11.7 volts allowing you to still start your boat or vehicle.

Soft Start, Noise Filtered Technology

- progressively increases the output voltage to

start heavy loads, with minimal or no interference.

TruePower performance features include:

- Internal Conformal Coating for Anti-Corrosion
- Soft Start and Noise Filtered Technology
- Bat’ Saver Mode – 200 to 1200 watt Models
- True Rated Continuous Power
- Hi-Surge Ratings for Demanding Loads
- Heavy Duty Marine/Industrial Construction
- Constructed to UL 458
- Meets the Requirements of ABYC E-11 Marine
- Highly Visible Power & Fault LED Indicators

TruePower Inverters are protected by a variety of features including:

- GFCI AC Outlet Safety Protected
- Input Polarity Protection
- Low Battery Alarm
- Low Battery Shutdown
- Overload Protection
- Output Short Circuit Protection
- Thermal Protection
- Over Voltage (15 VDC) Protection

Note: These inverters may not be suitable for use with some fluorescent lighting, halogen lights or
other inductive loads. If you wish to run such an item, plug it in to one of the inverter outlets and plug
in a small non-inductive load bearing item such as a low wattage light bulb into the other outlet.

Mounting your Inverter

IMPORTANT:

 ALWAYS PLACE THE INVERTER IN AN ENVIRONMENT WHICH IS:

(A) WELL VENTILATED
(B) NOT EXPOSED TO DIRECT SUNLIGHT OR HEAT SOURCE
(C) OUT OF REACH FROM CHILDREN
(D) AWAY FROM WATER / MOISTURE, OIL OR GREASE
(E) AWAY FROM ANY FLAMMABLE SUBSTANCE
(F) DO NOT INSTALL DIRECTLY ABOVE OR BELOW BATTERIES

Содержание 5020

Страница 1: ...t 400 Watt 110 VAC Output Inverter TruePowerInverterSeries 00 400Watt Portable Models Owner Manual Installation Guide Heavy Duty Marine Industrial Grade OnBoard Solutions A ProMariner Company ProMariner our Satisfaction is Important to us Do Not return this Product to the Retailer or ealer for any service or warranty requirements Please call our Customer Care epartment line at 1 800 824 0524 from ...

Страница 2: ...ent purchase of a TruePower Inverter eading the Marine industry in Power Conversion for over 30 years ProMariner s On oard Solutions division has designed a complete line of Power Inverters ranging from 0 to 3 000 watts specifically for Marine Industrial use TruePower Inverters will onvert your OnBoard 12VDC Battery power to 110VAC Household Power to run TV s aptops Gaming Systems power tools hair...

Страница 3: ...otes ...

Страница 4: ...from beginning to end WARNING This devise is not Ignition Protected voidseriousinjuryordeathfromorexplosion Donotinstallincompartmentscontaining asolinefueledenginesorgasolinetank orinareaswhereignitionprotectedequipment required WARNING Do not mount the inverter above or below your batteries WARNING Electrical shock and fire hazards nBoardSolutions aProMarinerCompanyrecommendsallwiringbedonebyqua...

Страница 5: ...on of consequential damages so the above limitations ay not apply to you This warranty is made in lieu of all other obligations or liabilities on the part of Onboard lutions and Professional Mariner Additionally On Board Solutions and Professional Mariner neither assumes r authorizes any person for any obligation or liability in connection with the sale of this product make a claim under warranty ...

Страница 6: ...Continuous Power Hi Surge Ratings for Demanding Loads Heavy Duty Marine Industrial Construction Constructed to UL 458 Meets the Requirements of ABYC E 11 Marine Highly Visible Power Fault LED Indicators uePower Inverters are protected by a variety of features including GFCI AC Outlet Safety Protected nput Polarity Protection Low Battery Alarm Low Battery Shutdown Overload Protection Output Short C...

Страница 7: ...ter or not work at all ote Some stereo systems and radios may emit a buzzing sound from their speakers hen operated from the inverter This buzzing occurs because the radio or electronic evice does not filter the modified sine wave produced by the inverter adequately elevision interference may occur with some TV signals even though this inverter designed to minimize such interference If a disturban...

Страница 8: ... Hours NowDividetheWattHoursby10todeterminehowmany12voltampere hourswillbeused ouneedtohaveabatteryorabankofbatterieswithsameampere hoursyoudemand the user has TruePower running off the start battery of your vehicle we recommend e user to start the vehicles engine very 30 minutes to recharge the battery This will elp prevent any automatic shutdown of the inverter due to low battery voltage and elp...

Страница 9: ...ery voltage may be too low Solution Battery voltage becoming low recharge battery and resume inverting power Possible Cause Over temperature Solution Allow the inverter to cool down The inverter will start automatically Possible Cause Unit may be defective Solution Call Factory Service 800 number No AC output voltage NO Lights are illuminated Possible Cause Battery voltage is too low Solution Rech...

Страница 10: ...tallation and operate the TruePower Inverter close he DC fuse or the DC circuit breaker to supply DC power to the TruePower inverter isplay Functions of the LED Light Pattern he ON OFF switch turns the TruePower inverter to ON or to OFF In the On position the Inverter Power LED light illuminates Green The TruePower begins inverting and provides AC power In the Off position the TruePower Inverter d...

Страница 11: ... to operating levels perating Several Appliances at the Same Time you are going to operate several appliances at the same time turn them on dependently after you have powered up the inverter This action ensures that the uePower does not have to deliver the starting current for all of the appliances at once he TruePower can accommodate several appliances at once as long as they do not ceed more tha...