I n s t a l l a t i o n   G u i d e l i n e s   /   Te s t i n g   Yo u r   I n v e r t e r

DC Wiring Options Continued

11. Connect the other connector of the NEGATIVE (-) cable onto the NEGATIVE (-) terminal
on the TruePower Inverter.

12. Use a wrench to tighten the nut. Test that all cable connections are tight.

Performing Checks Prior to Operation

Before starting up your inverter, ensure these conditions are met:

Verify the On/Off switch is in the Off position.

Verify the Positive (+) battery cable is connected to the positive (+) battery terminal.

Verify the Negative (-) battery cable is connected to the negative (-) battery terminal.

Verify the battery voltage is within the proper range for this unit (roughly 10-15.5 volts DC).

Verify the DC fuse is in tact.

Testing Installation

When you are ready to test your installation and operate the TruePower Inverter, close
the DC fuse or the DC circuit breaker to supply DC power to the TruePower inverter.

Display Functions of the LED Light Pattern:

The ON/OFF switch turns the TruePower inverter to ON or to OFF:

- In the On position, the Inverter Power LED light illuminates Green. The TruePower
   begins inverting and provides AC power.

- In the Off position, the TruePower Inverter draws no current from the battery.
  None of the front panel LED lights are illuminated.

- The Fault Light Illuminates Red when a fault conditions such as over temperature,
   output overload, or battery low voltage occurs.

To test the TruePower Inverter:

1. Turn the On/Off switch to the ON position.
    The Inverter/Fault LED light illuminates Green.

2. Plug an appliance of equal watts or less into the AC outlet.

3. Turn the appliance ON to verify that it operates.

If the Inverter/Fault light illuminates Red, see the TruePower Inverter
“Troubleshooting” section.

11

Tr o u b l e s h o o t i n g

No AC output voltage. No indicator lights are illuminated.

Possible Cause:

The switch is in Off position.

Solution:

-Turn the ON/Off switch to the ON position.

Possible Cause:

- No input power to the inverter.

Solution:

-Check the DC wiring to the inverter for loose connections or frayed wiring.

Possible Cause:

- DC fuse is blown.

Solution:

-Check user installed ABYC compliant fuse.
-Have a qualified service technician check and replace internal fuse.

No AC output voltage. Inverter light is illuminated.

Possible Cause:

- Circuit breaker has tripped.

Solution:

- Disconnect all appliances to reduce the overload, check the AC wiring, and reset
   the breaker by turning the ON/Off switch to Off and then back to ON.

Possible Cause:

- GFCI has tripped.

Solution:

- Clear the ground fault, and reset the GFCI by pressing the reset on the GFCI button.
   No AC output voltage. Red Fault LED light is illuminated.

Troubleshooting

This section is designed to accommodate you in identifying and troubleshooting
common problems that may result with an inverter. Review this section before
contacting customer service. If you can not resolve the problem, record the data
of the instance based on information provided here with in this manual.

This troubleshooting section will aid you in identifying the source of common problems
you may encounter. If you are unable to resolve the problem from the troubleshooting
reference table, contact customer service.

Содержание 5020

Страница 1: ...t 400 Watt 110 VAC Output Inverter TruePowerInverterSeries 00 400Watt Portable Models Owner Manual Installation Guide Heavy Duty Marine Industrial Grade OnBoard Solutions A ProMariner Company ProMariner our Satisfaction is Important to us Do Not return this Product to the Retailer or ealer for any service or warranty requirements Please call our Customer Care epartment line at 1 800 824 0524 from ...

Страница 2: ...ent purchase of a TruePower Inverter eading the Marine industry in Power Conversion for over 30 years ProMariner s On oard Solutions division has designed a complete line of Power Inverters ranging from 0 to 3 000 watts specifically for Marine Industrial use TruePower Inverters will onvert your OnBoard 12VDC Battery power to 110VAC Household Power to run TV s aptops Gaming Systems power tools hair...

Страница 3: ...otes ...

Страница 4: ...from beginning to end WARNING This devise is not Ignition Protected voidseriousinjuryordeathfromorexplosion Donotinstallincompartmentscontaining asolinefueledenginesorgasolinetank orinareaswhereignitionprotectedequipment required WARNING Do not mount the inverter above or below your batteries WARNING Electrical shock and fire hazards nBoardSolutions aProMarinerCompanyrecommendsallwiringbedonebyqua...

Страница 5: ...on of consequential damages so the above limitations ay not apply to you This warranty is made in lieu of all other obligations or liabilities on the part of Onboard lutions and Professional Mariner Additionally On Board Solutions and Professional Mariner neither assumes r authorizes any person for any obligation or liability in connection with the sale of this product make a claim under warranty ...

Страница 6: ...Continuous Power Hi Surge Ratings for Demanding Loads Heavy Duty Marine Industrial Construction Constructed to UL 458 Meets the Requirements of ABYC E 11 Marine Highly Visible Power Fault LED Indicators uePower Inverters are protected by a variety of features including GFCI AC Outlet Safety Protected nput Polarity Protection Low Battery Alarm Low Battery Shutdown Overload Protection Output Short C...

Страница 7: ...ter or not work at all ote Some stereo systems and radios may emit a buzzing sound from their speakers hen operated from the inverter This buzzing occurs because the radio or electronic evice does not filter the modified sine wave produced by the inverter adequately elevision interference may occur with some TV signals even though this inverter designed to minimize such interference If a disturban...

Страница 8: ... Hours NowDividetheWattHoursby10todeterminehowmany12voltampere hourswillbeused ouneedtohaveabatteryorabankofbatterieswithsameampere hoursyoudemand the user has TruePower running off the start battery of your vehicle we recommend e user to start the vehicles engine very 30 minutes to recharge the battery This will elp prevent any automatic shutdown of the inverter due to low battery voltage and elp...

Страница 9: ...ery voltage may be too low Solution Battery voltage becoming low recharge battery and resume inverting power Possible Cause Over temperature Solution Allow the inverter to cool down The inverter will start automatically Possible Cause Unit may be defective Solution Call Factory Service 800 number No AC output voltage NO Lights are illuminated Possible Cause Battery voltage is too low Solution Rech...

Страница 10: ...tallation and operate the TruePower Inverter close he DC fuse or the DC circuit breaker to supply DC power to the TruePower inverter isplay Functions of the LED Light Pattern he ON OFF switch turns the TruePower inverter to ON or to OFF In the On position the Inverter Power LED light illuminates Green The TruePower begins inverting and provides AC power In the Off position the TruePower Inverter d...

Страница 11: ... to operating levels perating Several Appliances at the Same Time you are going to operate several appliances at the same time turn them on dependently after you have powered up the inverter This action ensures that the uePower does not have to deliver the starting current for all of the appliances at once he TruePower can accommodate several appliances at once as long as they do not ceed more tha...

Отзывы: