23
OPERATING INSTRUCTIONS
2. Edit an existing program set using the
EDIT
button to the right of the program name.
3. Copy an existing program set using the
COPY
button to the right of the program name. This can
be especially useful for quickly duplicating a very similar set of programs.
4. Delete an existing program set using the
DELETE
button to the right of the program name.
5. Export an existing program set using the
EXPORT
button to the right of the program name.
• A .zip file containing your program set (schedule.txt), the latest firmware (firmware.bin), and
the final instruction for use (readme.txt) will download to your computer.
• Insert a USB stick.
• Copy the files needed (schedule.txt for programs, firmware.bin for firmware) to the top level
directory of the card (not in a folder or .zip file).
6. Insert the USB stick into the appliance, with the label side down.
Loading new firmware from a USB stick
1. Copy firmware.bin to a USB stick.
2. Insert the USB stick.
3. Press the reset button, and the five buttons will light in sequence from left to right.
4. The
:
and
E
buttons will light alternately.
5. Press and hold
:
for one second, and the display will show
LOAD
for about ten seconds.
6. The five buttons will light in sequence from left to right.
7. Remove the USB stick; the display will show the currently loaded firmware version and the pump
will run for one second.
8. Press
:
to turn on the power.
9. Be sure that the power is on and the appliance is in
RUN PROGRAM
mode prior to closing and
locking the door.
Programming the appliance from a USB stick
1. Copy schedule.txt to a USB stick.
2. Insert the USB stick.
3. Press the reset button, and the five buttons will light in sequence from left to right.
4. The
:
and
E
buttons will light alternately for about 15 seconds. Do not press any buttons yet.
7