![Prolitec Air/Q 310 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/prolitec/air-q-310/air-q-310_user-manual_1615444009.webp)
Installation
Room-Size Table
Output
Level Range
Room Volume
Range in CFT
Room Volume
Range in m
3
1 thru 5
200 – 800
6 – 23
6 thru 10
1,000 – 1,700
28 – 48
11 thru 15
1,900 – 2,800
54 – 79
16 thru 20
3,000 – 4,000
85 – 113
21 thru 25
4,200 – 5,300
119 – 150
26 thru 30
5,600 – 6,800
159 – 193
31 thru 35
7,200 – 8,600
204 – 244
36 thru 40
8,900 – 10,500
252 – 297
41 thru 45
10,900 – 12,600
309 – 357
46 thru 50
13,100 – 15,000
371 – 425
These settings are suggested as a starting point. Start on the lower end of the
range and adjust after 15 minutes. Room size, number of fresh air changes per
hour, temperature, humidity and user preference will determine the final setting.
Appliance Location
1. Placement of Air/Q
™
310 appliance is the KEY TO OPTIMAL PERFORMANCE.
It is important to identify a wall or track-light location where the output of
Air/Q 310 can use, rather than fight, the natural air currents in a room.
2. Air currents in a room are determined by using a SMOKE TEST KIT available
from Prolitec or any source of smoke or vapor, such as a candle or match.
3. To conduct a smoke test, stand at the entrance of the room in front of the door
and observe the direction of the smoke or vapor. If the smoke drifts into the
room Air/Q 310 appliance should be installed somewhere near the door.
7
Содержание Air/Q 310
Страница 1: ...Air Q 310 User Guide Revised 15 Jan 2013 Original Instructions...
Страница 2: ...2010 Prolitec Inc...
Страница 6: ...Unpacking 1 2 3 4 5 6 4...
Страница 17: ...Starting Up Features and Controls Output Ports Lock Air Stem Fragrance Cartridge Programming Panel 15...
Страница 34: ...Prolitec Incorporated 1235 Canal Street Milwaukee WI 53223 1667 1 866 387 4333 www prolitec com Part No 8530...