Step 4: Communication connection 

Communication port: 

USB port              RS-232 port         Intelligent slot 

 

 

 

To allow for unattended UPS shutdown/start-up and status monitoring, connect the 

communication cable one end to the USB/RS-232 port and the other to the communication port 

of your PC. With the monitoring software installed, you can schedule UPS shutdown/start-up and 

monitor UPS status through PC. 

 

The UPS is equipped with intelligent slot perfect for either SNMP or AS400 card. When installing 

either SNMP or AS400 card in the UPS, it will provide advanced communication and monitoring 

options.   

PS. USB port and RS-232 port can’t work at the same time.   

 

Step 5: Turn on the UPS   

Press the ON/Mute button on the front panel for two seconds to power on the UPS. 

Note: The battery charges fully during the first five hours of normal operation. Do not expect 

full battery run capability during this initial charge period. 

 

Step 6: Install software 

For optimal computer system protection, install UPS monitoring software to fully configure UPS 

shutdown. You may insert provided CD into CD-ROM to install the monitoring software. If not, 

please follow steps below to download and install monitoring software from the internet:

 

1. Go to the website 

http://www.power-software-download.com

 

2. Click ViewPower software icon and then choose your required OS to download the software.   

3. Follow the on-screen instructions to install the software. 

4. When your computer restarts, the monitoring software will appear as an orange plug icon 

located in the system tray, near the clock. 

 

Содержание PRO900-VL

Страница 1: ...ONLINE UPS User Manual PROFESSIONAL I SERIES 1P 1P TOWER PRO900 VS VL 1 3KVA Version 1 00 English ...

Страница 2: ...2 3 UPS Tower Rack Installation Only available for Rack UPS 9 2 4 Setup the UPS 10 2 5 Battery replacement Only for Rack UPS 12 2 6 Battery kit assembly Option for Rack UPS 13 3 Operations 15 3 1 Button operation 15 3 2 LED Indicators 16 3 3 UPS Setting 17 3 4 Operating Mode Description 18 3 5 Audible Alarm 19 3 6 Faults Reference Code 19 3 7 Warning indicator 19 4 Troubleshooting 20 5 Storage and...

Страница 3: ...ver them Do not connect domestic appliances such as hair dryers to UPS output sockets The UPS can be operated by any individuals with no previous experience Connect the UPS system only to an earthed shockproof outlet which must be easily accessible and close to the UPS system Please use only VDE tested CE marked mains cable e g the mains cable of your computer to connect the UPS system to the buil...

Страница 4: ...sulated grips and handles When changing batteries install the same number and same type of batteries Do not attempt to dispose of batteries by burning them This could cause battery explosion Do not open or destroy batteries Escaping electrolyte can cause injury to the skin and eyes It may be toxic Please replace the fuse only with the same type and amperage in order to avoid fire hazards Do not di...

Страница 5: ...g inside the package is damaged Please keep the original package in a safe place for future use 2 1 Rear panel view 1K India Type IEC Type Schuko Type Universal Type Argentina Type UK Type NEMA Type 2K India Type IEC Type Schuko Type Universal Type Argentina Type UK Type NEMA Type I NEMA Type II ...

Страница 6: ...4 3K India Type IEC Type Schuko Type Universal Type Argentina Type UK Type NEMA Type 1KL 2KL India Type IEC Type Schuko Type Universal Type Argentina Type UK Type ...

Страница 7: ...sal Type Argentina Type UK Type 1 AC input 2 Input circuit breaker 3 USB communication port 4 RS 232 communication port 5 SNMP intelligent slot option 6 External battery connection only available for L model 7 Output receptacles 8 Output terminal ...

Страница 8: ...6 Not in use For Rack Type Models Only ...

Страница 9: ...7 Not in use For Rack Type Models Only ...

Страница 10: ...8 Not in use For Rack Type Models Only ...

Страница 11: ...he UPS is shown as below 2 3 UPS Tower Rack Installation Only available for Rack UPS Rack mount Installation This UPS can be mounted in the 19 rack chassis Please follow below steps to position this UPS Step 1 Step 2 Tower Installation Step 1 Step 2 Step 3 ...

Страница 12: ...15 120 127VAC models The power cord is attached to the UPS The input plug is a NEMA 5 15P for 1K model and NEMA 5 20P for 2K model Step 3 UPS output connection For socket type outputs simply connect devices to the outlets For terminal type input or outputs please follow below steps for the wiring configuration a Remove the small cover of the terminal block b Suggest using AWG14 or 2 1mm2 power cor...

Страница 13: ...ss the ON Mute button on the front panel for two seconds to power on the UPS Note The battery charges fully during the first five hours of normal operation Do not expect full battery run capability during this initial charge period Step 6 Install software For optimal computer system protection install UPS monitoring software to fully configure UPS shutdown You may insert provided CD into CD ROM to...

Страница 14: ...12 2 5 Battery replacement Only for Rack UPS ...

Страница 15: ...13 2 6 Battery kit assembly Option for Rack UPS ...

Страница 16: ...14 Not in use For Rack Type Models Only ...

Страница 17: ... will be in standby mode under power normal or transfer to Bypass mode if the Bypass enable setting by pressing this button Confirm selection key Press this button to confirm selection in UPS setting mode Select Button Switch LCD message Press this button to change the LCD message for input voltage input frequency battery voltage output voltage and output frequency It will return back to default d...

Страница 18: ...ry level It indicates battery level by 0 25 26 50 51 75 and 76 100 when UPS is in battery or standby mode It indicates load level by 0 25 26 50 51 75 and 76 100 when UPS is in online bypass ECO and converter mode Indicates overload Indicates low battery level and low battery voltage Mode operation information Indicates the UPS connects to the mains Indicates the battery is working Indicates the by...

Страница 19: ...put voltage setting Interface Setting For 200 208 220 230 240 VAC models you may choose the following output voltage LED7 presents output voltage is 208Vac LED8 presents output voltage is 220Vac LED9 presents output voltage is 230Vac LED10 presents output voltage is 240Vac LED4 flashing Bypass enable disable when UPS is off Interface Setting Enable or disable Bypass function You may choose the fol...

Страница 20: ...ill charge battery under this mode ECO mode Energy saving mode When the input voltage is within voltage regulation range UPS will bypass voltage to output for energy saving Battery mode When the input voltage is beyond the acceptable range or power failure and alarm is sounding every 4 second UPS will backup power from battery Bypass mode When input voltage is within acceptable range but UPS is ov...

Страница 21: ... LED7 LED8 and LED 9 on Boost fault LED5 and LED10 on High voltage in charger LED5 LED7 LED8 LED9 and LED10 on Temperature abnormal LED5 LED7 and LED8 on Low voltage in charger LED5 LED8 LED9 and LED10 on 3 7 Warning indicator Warning LED flashing Alarm Input wiring is not connected correctly LED1 LED5 Sounding every second Battery is not connected LED2 LED5 Sounding every second Battery fault LED...

Страница 22: ...e and alarm is sounding twice every second UPS is overload Remove excess loads from UPS output UPS is overloaded Devices connected to the UPS are fed directly by the electrical network via the Bypass Remove excess loads from UPS output After repetitive overloads the UPS is locked in the Bypass mode Connected devices are fed directly by the mains Remove excess loads from UPS output first Then shut ...

Страница 23: ...aler Storage Before storing charge the UPS 5 hours Store the UPS covered and upright in a cool dry location During storage recharge the battery in accordance with the following table Storage Temperature Recharge Frequency Charging Duration 25 C 40 C Every 3 months 1 2 hours 40 C 45 C Every 2 months 1 2 hours Be sure to deliver the spent battery to a recycling facility or ship it to your dealer in ...

Страница 24: ...atio 3 1 Harmonic Distortion 3 THD linear load 6 THD non linear load Transfer Time AC Mode to Batt Mode Zero Inverter to Bypass 4 ms Typical Waveform Batt Mode Pure Sinewave EFFICIENCY AC Mode 88 89 90 Battery Mode 83 87 88 BATTERY Standard Model Battery Type 12 V 9 AH 12 V 9 AH 12 V 9 AH Numbers 2 4 6 Recharge Time 4 hours recover to 90 capacity Typical Charging Current 1 0 A max Charging Voltage...

Страница 25: ...TERS INDONESIA Office PT PROLiNK INTIDATA NUSANTARA Walk In Jl Cideng Barat No 79 Jakarta Pusat 10150 Indonesia Email Support support id prolink2u com MALAYSIA Office FIDA SYSTEMS M SDN BHD Walk In 29 Jalan USJ 1 31 47600 Subang Jaya Selangor Darul Ehsan Malaysia Email Support support my prolink2u com SINGAPORE Office FIDA INTERNATIONAL S PTE LTD Walk In Block 16 Kallang Place 06 02 Kallang Basin ...

Отзывы: