2. OPERATION                                   

 

2.1 Operating Instructions 

A.  Connect the AC input power cable of your UPS to the AC Power. ‘

YELLOW

’ LED on 

the UPS front panel is lit. UPS is charging the battery. 

(Note: DO NOT connect any 

load to your UPS until the UPS has charged its battery for 12 hours)

 

 
B.  Plug computer and monitor to UPS sockets. (

Note: Power of computer and monitor 

must be less than the maximum total power of your UPS.

 

DO NOT connect a laser 

printer to the UPS backup socket. Laser printers draw a significantly more power 
than other types of equipment and may overload the UPS.

 
C.  Switch on the UPS by pressing the power switch on the front panel. The ‘

GREEN

’ LED 

on the UPS front panel is lit and ‘

YELLOW

’ LED is off. UPS is supplying utility power to 

the connected equipment and is still charging battery at the same time.  

 
D.  When external power source fails, the UPS will power up automatically by batteries. 

The ‘

YELLOW

’ LED is blinking and the UPS has beep sound every 10 seconds. You 

should save all your data and close all applications as soon as possible and turn off the 
UPS.  

 
E.  When the battery output voltage drops to a minimum, the ‘

YELLOW

’ LED on the UPS 

front panel is blinking while generating beeps every 1 second. You should turn off the 
main switch of the UPS.  

 

2.2 UPS Status Information 

LED Indication 

UPS Status 

Buzzer 

Yellow 

Green 

Red 

Offline mode, Charge 

Battery 

No beeps 

ON 

OFF 

OFF 

AC mode, UPS Normal 

No beeps 

OFF 

ON 

OFF 

AC abnormal 

UPS in battery mode 

Once every 10 sec 

Blinking 

OFF 

OFF 

Battery voltage low 

Every sec 

Blinking 

OFF 

OFF 

Overload in AC mode 

Every 0.5 sec 

OFF 

ON 

OFF 

Overload in Battery mode 

Every 0.5 sec 

Blinking 

OFF 

ON 

UPS fault / Short circuit 

Continuous Sounding 

OFF 

OFF 

ON 

Discharge Finished 

No beep 

OFF 

OFF 

OFF 

2

Содержание EnerHome PRO PRO700

Страница 1: ......

Страница 2: ...Blk 16 Kallang Place 06 02 Singapore 339156...

Страница 3: ...l battery and its energy can not be de energized by the user The output may be energized even though when the UPS is not connected to the main AC DO NOT install the UPS in locations where there is wat...

Страница 4: ...till charging battery at the same time D When external power source fails the UPS will power up automatically by batteries The YELLOW LED is blinking and the UPS has beep sound every 10 seconds You sh...

Страница 5: ...r cable not properly inserted 3 Change the fuse 3 Fuse blown 4 Faulty wall socket 4 Change to another wall socket 1 Check that your equipment matches the specified capacity of your UPS Do not overload...

Страница 6: ...re protection CPU Protection Monitoring Surge Protection Yes Alarms Audible Visual Over Temperature Protection 75 C Alarm will sound 85 C the system will shutdown Line Mode 100 120 5 minutes change to...

Страница 7: ...isa dibuang Output dari UPS sendiri akan mengeluarkan arus listrik walaupun UPS tidak dihubungkan langsung ke aliran JANGAN meletakan UPS di dekat daerah yang lembab atau basah JANGAN biarkan air atau...

Страница 8: ...tika sumber listrik padam UPS akan bekerja secara otomatis dengan menggunakan baterai Lampu KUNING akan berkedip dan diikuti dengan suara beep di setiap 10 detik Saat ini anda harus menyimpan seluruh...

Страница 9: ...tus 3 Ganti sekering yang putus 4 Kerusakan di soket koneksi listrik pada dinding 4 Ganti ke soket listrik yang lainnya 1 Periksa semua peralatan yang terhubungkan ke UPS Pastikan beban tidak melebihi...

Страница 10: ...re protection CPU Protection Monitoring Surge Protection Yes Alarms Audible Visual Over Temperature Protection 75 C Alarm will sound 85 C the system will shutdown Line Mode 100 120 5 minutes change to...

Страница 11: ...UR Mon to Fri 9am 6pm Closed on Saturdays Sundays Public Holidays Singapore FIDA INTERNATIONAL S PTE LTD Blk 16 Kallang Place 06 02 Kallang Basin Industrial Estate Singapore 339156 Malaysia FIDA SYSTE...

Страница 12: ...support_my fida com INDONESIA PROLiNK INDONESIA P Jayakarta Komplek 85 BR AJ Jakarta Pusat Indonesia Tel 62 21 628 3205 Email support prolink co id 2009 Fida International S Pte Ltd Version 1 0 Jul 09...

Отзывы: