34
Connection to power supply
The socket should be connected in compliance with the relevant standard, to a dedicated
omnipolar circuit breaker. 25 A minimum supply.
Monophase 230V~ 1P+N
Put a bridge between terminal 1 and 2
Attach the green/yellow wire to the terminal Earth
The neutral N to the terminal 4
The phase L to one of the terminal 1 or 2
Biphase 400V~ 2P+N
Attach the green/yellow wire to the terminal Earth
The neutral N to the terminal 4
The phase L1 to the terminal 1 and the phase L2 to the terminal 2
* calculated with the simultaneous factor following standard EN 60 335-2-6
Caution!
Tightening the screws too much can damage the screw thread. It is therefore
advisable to keep screwing and unscrewing to a minimum.
Ensure that the cables are correctly inserted and tightly screwed down.
Mains
Connection
Cable diameter
Cable
Protection calibre
230~ 50/60Hz
1 Phase + N
3 x 2,5 mm
2
H 05 VV - F
H 05 RR - F
25 A *
400V~ 50/60Hz
2 Phase + N
4 x 1,5 mm
2
H 05 VV - F
H 05 RR - F
16 A *
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
equipped with a faulty earth connection.