![Proline SLC 116PEW Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/proline/slc-116pew/slc-116pew_service-manual_1614902021.webp)
Page 20
N
Examine if NTC is damaged
( short circuit or cut off )
Examine if the tank is full with
water
Examine if the float pole to its
original place
Code
⧜
Error message: The Pump fails.
Y
Y
Y
Empty the tank and restart
the dryer
Y
Move the float pole to its
original place by your
hand
Y
Repalce the NTC
Examine if the drainage pipe is
blocked
Y
Empty the drainage pipe
The pump fails
Y
Replace the old pump
with a new one
Trouble
˖
The heater does not work or works abnormally
N
Open the back plate and
slightly press the red button
on the thermostat to make it
reset
Examine if the thermostat near
the heater works ( It is closed )
Make sure the connection
lines are inserted correcting
Examine if the connection lines into
heater correctly
N
Repalce the old heater with
a new one
Y
Examine if the heater is damaged
( short circuit or cut off )
the sequence of
insert lines
Heater
Float pole
drainage
Pump
N
N