![Proline SLC 116PEW Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/proline/slc-116pew/slc-116pew_service-manual_1614902020.webp)
Page 19
N
Check if the load or clothes inside
the drum reached the setting
degree
Check if the sensor circuit lines are
connected normally
Code
˖
Error message : Prompting there is no load or the loaded laundry has reached the requirements
for the dry setting.
Y
Normally indicate the
information
N
Insert the sensor
Y
N
The brush should be
installed close to the
drum and sensor slice
Chek whether the brush is
installed properly
Code
˖
Error message: NTC is short circuit or cut out
DŽ
Y
Check if the NTC terminals are
inserted properly
Insert the NTC terminals
properly
N
NTC connection
Humidity sensor
Sensor lines
Condenser Tumber Dryer
SLC 116PEW
Code
Error message: The laundry not dried.
N
N
Consult the users to see if there
are wrong operations
Check whether the heater can
work normally
Check whether the lint screen
is blocked
1
Do not put the clothes
dripping water into drum
2
Do not overload the dryer
3
Avoid adding clothes into
the drum when the drying
cycle is nearly finished
Y
Replace the heater which
can not work
N
Clear the lint screen
Y
Replace the Thermostat
Which can not work
Check whether the
Thermostat
N
Y
short circuit or cut off.
Thermostat