5
7.
Integrate the hood in the cut out, and fix it with the 8 supplied screws (3.5mm diameter, 16mm depth).
Electrical connection
For your safety, ask a qualified technician to perform the electrical installation of the hood.
The mains power supply must correspond to the rating indicated on the plate situated inside the
hood. If provided with a plug connect the hood to a socket in compliance with current
regulations and positioned in an accessible area, after installation. If it not fitted with a plug
(direct mains connection) or if the plug is not located in an accessible area, after installation,
apply a double pole switch in accordance with standards which assures the complete
disconnection of the mains under conditions relating to over
‐
current category III, in accordance
with installation instructions.
Warning!
Before re
‐
connecting the hood circuit to the mains supply and checking the efficient function,
always check that the mains cable is correctly assembled.
USING YOUR APPLIANCE
Ducting version
In this case the fumes are conveyed outside of the building by means of a special pipe connected with
the flange located on top of the hood.
Beware!
The exhaust pipe and ring are not supplied and must be purchased apart.
In the horizontal runs the exhausting pipe must be slightly slanted (about 10°) and directed upwards to
vent the air easily from the room to the outside.
Beware!
If the hood is supplied with active charcoal filter, then it must be removed.
Connect the hood and discharge holes on the walls with a diameter equivalent to the exhaust pipe
(flange and ring). Using tubes and discharge holes on walls with smaller dimensions will affect the
suction performance and drastically increase the noise.