![Proline CAPTURE DMX512 Скачать руководство пользователя страница 4](http://html.mh-extra.com/html/proline/capture-dmx512/capture-dmx512_user-manual_1614849004.webp)
RESET-clearing down the device
Press BlackOut and switch on the device. After 4.sec display screen "CC" and whole
memory of the device clear down.
Setting size of packet
Press AUDIO/WRITE and switch on the device. After 4 sec display hexadecimal value big
as a input packet. By buttons PRG UP and PRG DOWN you adjust the value and confirm
by BlackOut. Size of input packet determine way of CAPTURE regulation of notation
into memory. For illustration: DMX controller USC-128 transmit in maximal configuration
/16 scanners-8 channels/ 128 B packet /16x8/. It means that in case of setting packet on
size FF / can be 00/ is packed big 256 bytes and 128 bytes is idle and takes place in
memory witch you can use other way.
Choice of some hexadecimal values:
hexa decimal hexa decimal
10
16
60 96
20
32
80
128
40
64
FF
255
Protection of written programs
In case you want to save your data written in memory you can use program Lock. The
Lock is applied by following way :
5
by button PRG DOWN and PRG UP you choice program
5
by pressing BlackOUT, PRG DOWN, PRG UP together you lock or unlock an
actually program. According to condition on a display is "CL" - closed/lock/, "oP"
- open /unlock/.
5
If you want to rewrite locked programs, on a display is "CL" and don´t allow write.
Technical specification
Supply voltage
adapter 12V
Fuse
T 100mA 5x20mm
Power consumption
10VA
Weight
1 Kg
Dimensions
205x160x45
DMX input/output
DMX 512 /1990/ 4us, 6,35 stereo Jack
/Data+, Data,-, OV/
Your distributor :
Содержание CAPTURE DMX512
Страница 1: ...Capture DMX512 USER manual ...