background image

PROLIGHTS - EclProfile 

FW IP

15

9 - MENU STRUCTURE 

The following chart describes the MENU tree of the product, the terms shown in 

BOLD

 indicates the 

default settings.

MENU

1 Connect

DMX Address

001 - 512

DMX Mode

Gobo Rot OFF

Gobo Rot 

ON

Uno

Uno Gobo

Duo

Basic Gobo

Standard

Std Gobo

2 Advanced

Dimmer Curve

Linear

S-Curve

Square Law

Inverse Square Law

Select different curve behaviour of dimmer.

Dimmer Speed

Auto

Slow

Medium

Fast

Linear speed behaviour.

Dimmer speed adding long fade.

Dimmer speed adding medium fade.

Dimmer speed adding little fade.

LED Frequency

600 Hz

1282 Hz

2500 Hz

5000 Hz

6400 Hz

25 kHz

Select PWM frequency.

Fan Mode

Auto

Balanced

Silent

Full

Select 

the 

product 

Fan 

mode.

 

Auto mode: fan speed from 0% to 100% following 

temperature curve.

Balanced  mode:  fan  speed  from  0%  to  50% 

following temperature curve.

Silent mode: speed fan from 0% to 30% following 

temperature curve.

Full  mode:  fan  speed  at  100%  without  following 

fixture temperature.

Gobo Rot.

Off 

On

Enable 

Disable 

Gobo 

functionality.

 

DMX  Mode  in  use  is  automatically  converted  to 

"Gobo"  version.  DMX  Mode  list  is  switched  to 

"Gobo Rot On" version.

3

SETUP

Display Flip

Regular

Top Down

Allows you to rotate the display

by 180°.

Back Light

On

10 s

20 s

30 s

Allows you to select the timing after that display 

will switch automatically off when unactive.

Key Lock

Locked

Unlocked

Allows you lock the buttons on the control panel 

by a password.

Press following combinations (password) in order 

to  access  to  the  user  menu:  UP,  DOWN,  UP, 

DOWN.

Gobo Rot. Reset

Abort 

Reference

Transfer Config

Abort

Without DMX Addr

With DMX Address

To transfer the same menu settings of one fixtures 

to all the other in the daisy chain, including or not 

the dmx address.

Содержание EclProfile FW IP

Страница 1: ...USER MANUAL REV 01 02 22 English version EclProfile FW IP High quality Full White LED ellipsoidal available in Tungsten and Daylight versions...

Страница 2: ...conomic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document Product user manual can be downloaded from the website www prolights...

Страница 3: ...DDRESSING 13 8 CONTROL PANEL 14 DISPLAY AND BUTTONS LAYOUT 14 9 MENU STRUCTURE 15 10 RDM FUNCTIONS 17 11 SHORTCUTS 18 12 ERROR MESSAGES 18 13 DMX CHARTS 19 13 ACCESSORIES INSTALLATION 24 OPTIC CODE EC...

Страница 4: ...and cables are in perfect condition and rated for the current requirements of all connected devices Isolate the fixture from power immediately if the power plug or any seal cover ca ble or other compo...

Страница 5: ...equate cleaning or maintenance are not covered by the product warranty T 58 C c Temperature of the external surface The surface of the fixture can reach up to 58 C 136 4 F during operation Avoid conta...

Страница 6: ...Compatibility EMC 2011 65 EU Restriction of the use of certain hazardous substances RoHS The products to which this manual refers comply with UL 1573 CSA C22 2 No 166 Stage and Studio Luminaires and C...

Страница 7: ...Profile fixtures black housing ECLPRL26BK 26 PRL lens barrel for EclProfile fixtures black housing ECLPRL36BK 36 PRL lens barrel for EclProfile fixtures black housing ECLPRL50BK 50 PRL lens barrel for...

Страница 8: ...PROLIGHTS EclProfile FW IP 06 2 TECHNICAL DRAWING Weight 7 3 kg 16 09 lbs ECLFWIP without optic Weight 10 2 kg 22 48 lbs ECLFWIP with ECLPRL05 Weight 9 2 kg 20 28 lbs ECLFWIP with ECLPRL10...

Страница 9: ...LPRL14 Weight ECLPRL19 9 5 kg 20 94 lbs Weight ECLPRL26 9 7 kg 21 38 lbs Weight ECLPRL36 9 4 kg 20 72 lbs Weight ECLPRL50 9 kg 19 84 lbs ECLFWIP with ECLPRL19 ECLFWIP with ECLPRL26 ECLFWIP with ECLPRL...

Страница 10: ...PROLIGHTS EclProfile FW IP 08 Weight 11 3 kg 24 91 lbs ECLFWIP with ECLPRLZ1530 Weight 11 3 kg 24 91 bs ECLFWIP with ECLPRLZ2550 Fig 01...

Страница 11: ...ing a safety wire that is approved as a safety attachment for the weight of the fixture to an anchor point on the product main frame Do not use removable parts or weak anchors for secondary attachment...

Страница 12: ...wer from the product disconnect the Mains from the socket 4 CONNECTION TO THE MAINS SUPPLY WARNING For protection from electric shock the fixture must be earthed The product is equipped with auto swit...

Страница 13: ...FACE with display and buttons for access to the control panel functions 10 DMX IN 5 p XLR 1 GND 2 sign 3 sign 4 N C 5 N C 11 DMX OUT 5 p XLR 1 GND 2 sign 3 sign 4 N C 5 N C 12 MAIN FUSE HOLDER replace...

Страница 14: ...the connection line Do not overload the link Up to 32 devices may be connected on a serial link CONNECTION DAISY CHAIN Connect the DMX data output from the DMX source to the product DMX input male con...

Страница 15: ...be executing the same behaviour Selecting the same address to multiple fixtures can be useful for diagnostic purposes and symmetrical control DMX addressing is limited to make it impossible to set th...

Страница 16: ...emporary turn ON the product at Full ON for user focusing operations MENU Used to access the menu tree or to return a previous menu window UP Browse upwards through the menu list and increases the num...

Страница 17: ...rve Balanced mode fan speed from 0 to 50 following temperature curve Silent mode speed fan from 0 to 30 following temperature curve Full mode fan speed at 100 without following fixture temperature Gob...

Страница 18: ...o Rot F 0 255 0 0s 30 0s 60 0s 0 100 0 100 0 255 0 255 Edit and choose effect 1 Effect 3 Dimmer Duration Attack Decay Gobo Rot Gobo Rot F 0 255 0 0s 30 0s 60 0s 0 100 0 100 0 255 0 255 Edit and choose...

Страница 19: ...es from specific fixtures The PIDs in the following tables are supported in the product Parameter PID GET SET SUPPORTED_PARAMETERS 0x0050 x DEVICE_INFO 0x0060 x x DEVICE_MODEL_DESCRIPTION 0x0080 x MAN...

Страница 20: ...nput Error T Can t read status Error Temperature management Overtemperature Error LED Temperature Error Cannot read LED tem perature Transfer config DMX active Error Cannot transfer with active DMX Fl...

Страница 21: ...89 190 191 251 252 255 255 4 CONTROL No Function Safe Reserved Dimmer Mode Linear Dimmer Mode S Curve Dimmer Mode Square Law Dimmer Mode Inverse Sq Law Dimmer Speed Auto Dimmer Speed Slow Dimmer Speed...

Страница 22: ...X Chart with Gobo Rotation enabled Ch Uno Gobo Duo Gobo Standard Gobo 1 DIMMER COARSE DIMMER COARSE DIMMER COARSE 2 GOBO ROT DIMMER FINE DIMMER FINE 3 GOBO ROT FINE GOBO ROT STROBE 4 GOBO ROT FINE CON...

Страница 23: ...0 94 Pos 123 75 Pos 126 56 Pos 129 38 Pos 132 19 Pos 135 00 Pos 137 81 Pos 140 63 Pos 143 44 Pos 146 25 Pos 149 06 Pos 151 88 Pos 154 69 Pos 157 50 Pos 160 31 Pos 163 13 Pos 165 94 Pos 168 75 Pos 171...

Страница 24: ...7 06 rpm CW Spin 16 29 rpm CW Spin 15 52 rpm CW Spin 14 78 rpm CW Spin 14 06 rpm CW Spin 13 35 rpm CW Spin 12 66 rpm CW Spin 11 99 rpm CW Spin 11 34 rpm CW Spin 10 71 rpm CW Spin 10 09 rpm CW Spin 9 5...

Страница 25: ...12 67 rpm CCW Spin 13 35 rpm CCW Spin 14 06 rpm CCW Spin 14 79 rpm CCW Spin 15 53 rpm CCW Spin 16 29 rpm CCW Spin 17 07 rpm CCW Spin 17 86 rpm CCW Spin 18 68 rpm CCW Spin 19 51 rpm CCW Spin 20 37 rpm...

Страница 26: ...IP 24 13 ACCESSORIES INSTALLATION OPTIC CODE ECLPRL OPTIONAL 1 Loosen and remove the two marked knobs of the optic 2 A B B Mount the desired optic A in the middle part Then insert and tighten the knob...

Страница 27: ...the top of the optics body outwards and lift it B 2 B A DETAIL Insert the filter A into the marked track DETAIL and close the clip B always applying an outward push NOTE To remove the accessory revers...

Страница 28: ...obo dimensions Type B external OD 86 mm 3 4 in of image ID 64 5 mm 2 5 in Thinckness 1 1 mm 0 04 in 1 Put in place the gobo 2 ATTENTION Load with mirror surface toward the light source Please turn GOB...

Страница 29: ...screws A Then open the slot of the middle part B 3 A Insert the gobo holder into the slot The flaps A will go into the appropriate size NOTE To remove the accessory reverse the procedure Fig 11 PROLI...

Страница 30: ...ODE ECLPRIRIS OPTIONAL 1 A A B Loosen the marked screws A Then open the slot of the middle part B 2 A Insert the steel iris diaphram into the slot The flaps A will go into the appropriate size NOTE To...

Страница 31: ...ODE ECLPRSEF1 OPTIONAL 1 A A B Loosen the marked screws A Then open the slot of the middle part B 2 A Insert the soft edge filter into the slot The flaps A will go into the appropriate size NOTE To re...

Страница 32: ...D C A B Loosen the marked knob A and screw B Then rotate C the middle part and remove it D 2 DETAIL A B Insert the soft focus diffusion A by placing the magnets DETAIL on the back of the framing syste...

Страница 33: ...ED YOKE CODE ECLPRPOYO OPTIONAL 1 A A B Loosen and remove the marked screws A Then remove the bracket B 2 A DETAIL Mount the Pole Operated Yoke bracke A and tighten the screws DETAIL NOTE To remove th...

Страница 34: ...and insert the new gobo B following the procedure shown in the image DETAIL Loosen the marked screws C Then open the slot of the middle part D 2 A B C Insert the soft edge filter into the slot The fla...

Страница 35: ...e to the IPTESTBOX by inserting the quick connect fitting into the coupler 2 Insert the threaded end into the threaded valve hole socket 3 For the operating procedure using the instrument refer to the...

Страница 36: ...ied personnel It is PROLIGHTS policy to apply the strictest possible calibration procedures and use the best quality materials available to ensure optimum performance and the longest possible componen...

Страница 37: ...ectors and connect them directly together to bypass one product at a time until normal operation is regained Once found the error have that fixture serviced by a qualified technician Timeout error aft...

Страница 38: ...Note...

Страница 39: ......

Страница 40: ...PROLIGHTS is a trademark of MUSIC LIGHTS S r l musiclights it prolights it support prolights it Via A Olivetti snc 04026 Minturno LT ITALY Tel 39 0771 72190...

Отзывы: