background image

PROLIGHTS - EclMiniProfile 

WDMX / TRWD

11

9 - MENU STRUCTURE 

The following chart describes the MENU tree of the product, the terms shown in 

BOLD

 indicates the 

default settings.

MENU

1 Auto Show

Auto Show

Speed

<Auto 1>

<100>

<Auto 2>

<100>

<Auto 3>

<100>

<Auto 4>

<100>

2 Static

<Dimmer>

<255>

<Strobe>

<0>

3 Dimmer Mode

<On>

To choose the dimmer curve.

<Dimmer 1>

<Dimmer 2>

<Dimmer 3>

4 Back Light

<On>

Allows you to select the timing 

after that display will switch aut 

matically off when unactive.

<10S>

<20S>

<30S>

5 Information

Fixture Hours

<9999H>

To view infromation about the unit.

Version

<V1.0>

6 DMX Address

<001>

7 DMX Channel

<1Ch>

<2Ch>

<5Ch>

8 Master/Slave

<Master>

Allow you to link and operating in 

synk multiple units without a DMX 

console. Choose a unit to perform 

as  the  Master.  This  unit  must  be 

the first unit in line; Set the suces

-

sive units to be slave.

<Slave>

9 Wireless Setting

Receive Setting

<On>

Receive Setting: used to turn on/

off wireless functionality

 

Receive Reset: used to link fixture 

to transmitter

<Off>

Receive Reset

<No>

<Yes>

Содержание EclMiniProfile TRWD

Страница 1: ...USER MANUAL REV 02 04 21 English version EclMiniProfile WDMX 28W track mounted mini LED profile with W DMX control Mini LED profile with WDMX control EclMiniProfile TRWD...

Страница 2: ...or any other loss occasioned by the use of inability to use or reliance on the information contained in this document Product user manual can be downloaded from the website www prolights it or can be...

Страница 3: ...M THE PRODUCT 07 6 PRODUCT OVERVIEW 08 7 DMX CONNECTION 09 DMX ADDRESSING 09 8 CONTROL PANEL 10 DISPLAY AND BUTTONS LAYOUT 10 9 MENU STRUCTURE 11 10 DMX CHARTS 12 11 GOBO INSERTION 13 OPTIC CODES MINI...

Страница 4: ...cables are in perfect condition and rated for the current requirements of all connected devices Isolate the fixture from power immediately if the power plug or any seal cover ca ble or other component...

Страница 5: ...nd will damage the fixture Damages caused by inadequate cleaning or maintenance are not covered by the product warranty T 70 C c Temperature of the external surface The surface of the fixture can reac...

Страница 6: ...environment please dispose recycle this product at the end of its life according to the local regulation The products to which this manual refers comply with 2014 35 EU Safety of electrical equipment...

Страница 7: ...INIECLWD optics for MINIECL profiler gobo holder included 26 beam MINIECLL36 for MINIECLWD optics for MINIECL profiler gobo holder included 36 beam MINIECLL50 for MINIECLWD optics for MINIECL profiler...

Страница 8: ...attaching a safety wire that is approved as a safety attachment for the weight of the fixture to an anchor point on the product main frame Do not use removable parts or weak anchors for secondary atta...

Страница 9: ...rom the socket 4 CONNECTION TO THE MAINS SUPPLY WARNING For protection from electric shock the fixture must be earthed The product is equipped with auto switching power supply that automatically adjus...

Страница 10: ...EUTRAC STAFF GLOBAL IVELA Eurostandard Plus compatible 2 SCREW to regolate housing gobos 3 BLADES for FRAMING SYSTEM 4 SAFETY EYE to attach safety cable 5 GOBO HOUSING 6 FOCUS AND ZOOM KNOB 7 USER IN...

Страница 11: ...ith out enough control channels for the product To set the fixture s DMX address 1 Press MENU to open the main menu 2 Reach the addressing menu then select the DMX ADDRESS settings 3 Select the addres...

Страница 12: ...ns for access to the control panel functions MENU used to access the menu tree or to return a previous menu window UP browse upwards through the menu list and increases the numeric value displayed DOW...

Страница 13: ...after that display will switch aut matically off when unactive 10S 20S 30S 5 Information Fixture Hours 9999H To view infromation about the unit Version V1 0 6 DMX Address 001 7 DMX Channel 1Ch 2Ch 5Ch...

Страница 14: ...to fast 000 011 011 255 255 3 AUTO PROGRAMS Auto Program 1 Auto Program 2 Auto Program 3 Auto Program 4 000 010 011 070 071 130 131 190 191 255 000 4 AUTO SPEED 0 100 000 255 000 5 DIMMER SPEED Prese...

Страница 15: ...0 MINIECLTRL19 26 36 50 OPTIONAL The mounting procedure is the same for all lenses 1 C A B Loosen the marked screw A and open the slot B Then extract the gobo holder C 2 DETAIL B A Open the gobo holde...

Страница 16: ...CLL19 26 36 50 MINIECLTRL19 26 36 50 OPTIONAL The mounting procedure is the same for all lenses 1 A B C 2 3 Loosen the marked knob 1 A of the unit Rotate the optic 45 1 B and insert it 1 C so the mark...

Страница 17: ...s All other service operations on the product must be carried out by PROLIGHTS its approved service agents or trained and qualified personnel It is PROLIGHTS policy to apply the strictest possible cal...

Страница 18: ...nician Timeout error after fixture reset One or more hardware components requires mechanical adjustments Check product stored error messages for more information Contact PROLIGHTS Service or an author...

Страница 19: ...Note...

Страница 20: ...Note...

Страница 21: ...Note...

Страница 22: ...Note...

Страница 23: ......

Страница 24: ...PROLIGHTS is a trademark of MUSIC LIGHTS S r l musiclights it prolights it support prolights it Via A Olivetti snc 04026 Minturno LT ITALY Tel 39 0771 72190...

Отзывы: