1.1 DIGIDRIVERIP

DIGIDRIVERIP is a driver which provides power and processing to the DIGISTRIPIP. It has 2 outputs and can 
control up to 20 DIGISTRIPIP100s and 40 DIGISTRIPIP50s - each offering the control of up to 3.600 pixels in 
a one rack unit, offering 20 DMX universes and 546 W of power in and out. DIGIDRIVERIP cannot control 
DIGISTRIP, DIGITUBE and DIGITILE. DIGIDRIVERIP is compatible with Art-Net, Kling-Net and sACN protocols 
and runs signal and power over a 4 pole XLR cable that allow wiring of units in a chain. The user interface 
consists of a black OLED display for settings, protocol selection, network address and test patterns. IP 65 
rating allows for the usage at outdoor events so humidity and rain are no longer a worry

BODY

•  Hardware on-board: Included rack-mount hardware
•  Body: sturdy die-cast aluminium body conceived for long-time durability
•  Body colour: black
•  Other: 2U rack

CONTROL

•  Control units: 20 x DIGISTRIPIP100 or 40 x DIGISTRIPIP50
•  Art-Net channels: 20x512ch
•  Protocols: Art-Net, Kling-Net, sACN
•  Pixel control: pixel2pixel control
•  Display: black OLED high resolution display

ELECTRONICS

•  Operating temperature: -20° ~ +45°

ELECTRICAL

•  Power supply: 100-240 V – 50/60 Hz
•  Power consumption (at 230 V): 546W
•  Power consumption (at 120 V): 570W
•  Output (at 230 V): 5 units on a single power line
•  Output (at 120 V): 2 units on a single power line

PHYSICAL

•  Cooling: natural cooling of the peculiar chassis and to absence of fans
•  Sospension and fixing: any position with quick-lock omega brackets
•  Signal connection: 2xRJ45 and 4p out
•  Power connection: Seetronic powerCON waterproof IN/OUT connectors
•  IP rating: 65 for outdoor installations
•  Dimensions (WxHxD): 483x84x250 mm
•  Weight: 4.5 kg

Fig.1

Technical drawing

84

483

263

Содержание DIGIDRIVERIP

Страница 1: ...USER MANUAL MANUALE UTENTE EN IT DIGIDRIVERIP DIGISTRIPIP50 DIGISTRIPIP100 MASTER DRIVER PIXEL MAP LED BAR...

Страница 2: ...means for any commercial use In order to improve the quality of products Music Lights S r l reserves the right to modify the characteristics stated in this instruction manual at any time and without...

Страница 3: ...ription and Technical specifications 1 1 DIGIDRIVERIP 1 2 DIGISTRIPIP50 1 3 DIGISTRIPIP100 1 4 Operating elements and connections 2 Installation 2 1 Mounting 2 2 Maximum cable distance 3 Functions and...

Страница 4: ...r a disposal which is not harmful to the environment Warnings and installation precautions If this device will be operated in any way different to the one described in this manual it may suffer damage...

Страница 5: ...onger a worry BODY Hardware on board Included rack mount hardware Body sturdy die cast aluminium body conceived for long time durability Body colour black Other 2U rack CONTROL Control units 20 x DIGI...

Страница 6: ...25W RGB LEDs Luminous flux without cover 263 lm black cover 60 lm flat white cover 202 lm dome white cover 202lm Luminous flux without cover 4 320 nit black cover 727 nit flat white cover 1 233 6 nit...

Страница 7: ...Luminous flux without cover 620 lm black cover 101 lm flat white cover 382 lm dome white cover 411lm Luminous flux without cover 8 639 7 nit black cover 1 454 7 nit flat white cover 2 467 3 nit dome...

Страница 8: ...ions and manage them 3 GND POINT used for the grounding of the device 4 POWER IN PowerCON IN mains plug for connection to a socket 100 240V 50 60Hz via the supplied mains cable 5 POWER OUT PowerCON OU...

Страница 9: ...ng holes on the housing as shown in figure 7 2 2 MAXIMUM CABLE DISTANCE Max cable distance between two fixtures No maximum distance between the 2 devices The last DIGISTRIP need to stay under 60m dist...

Страница 10: ...ect the supplied main cable to a socket 100 240V 50 60Hz Then the unit is ready for operation and can be operated via a DMX controller or it independently performs its show program in succession To sw...

Страница 11: ...rt A Art Net Kling Net sACN Default Art Net Port B Art Net Kling Net sACN Default Art Net 5 DISPLAY INVERSE No Yes Default No 6 FACTORY RESET No Yes Default Off 7 PORT A Personality 7 CH Drive 8 CH Fi...

Страница 12: ...5 Section 50 Section PixelTOPixel Default PixelTOPixel Net 0 127 Default 0 Subnet 0 15 Default 0 Universe 0 15 Default 0 sACN Universe 1 247 Default 1 IP Address IP Address 1 IP Address 10 Art net IP...

Страница 13: ...Auto 6 Auto 7 Auto 8 Auto 9 Auto 10 Auto 11 Auto 12 Auto 13 Auto 14 Auto 15 Auto 16 Auto 17 Auto 18 Auto 19 Auto 20 Auto 21 Auto 22 Auto 23 Auto 24 Auto 25 All Auto Auto 1 25 000 010 011 020 021 029 0...

Страница 14: ...1 Auto 22 Auto 23 Auto 24 Auto 25 All Auto Auto 1 25 000 010 011 020 021 029 030 039 040 048 049 057 058 067 068 076 077 086 087 095 096 104 105 114 115 123 124 133 134 142 143 151 152 161 162 170 171...

Страница 15: ...BACKGROUND STROBE NO Function Slow to Fast Strobe 000 010 011 255 9 BACKGROUND RED 0 100 000 255 10 BACKGROUND GREEN 0 100 000 255 11 BACKGROUND BLUE 0 100 000 255 13 CHANNELS MODE FUNCTION DMX Value...

Страница 16: ...0 100 000 255 15 CHANNELS 5 SECTION FUNCTION DMX Value 15 Ch 1 RED 1 0 100 000 255 2 GREEN 1 0 100 000 255 3 BLUE 1 0 100 000 255 4 RED 2 0 100 000 255 5 GREEN 2 0 100 000 255 6 BLUE 2 0 100 000 255...

Страница 17: ...GREEN 9 0 100 000 255 27 BLUE 9 0 100 000 255 28 RED 10 0 100 000 255 29 GREEN 10 0 100 000 255 30 BLUE 10 0 100 000 255 75 CHANNELS 25 SECTION FUNCTION DMX Value 75 Ch 1 RED 1 0 100 000 255 2 GREEN 1...

Страница 18: ...9 0 100 000 255 147 BLUE 49 0 100 000 255 148 RED 50 0 100 000 255 149 GREEN 50 0 100 000 255 150 BLUE 50 0 100 000 255 300 CHANNELS PixelTOPixel FUNCTION DMX Value 300 Ch 1 RED 1 0 100 000 255 2 GREE...

Страница 19: ...17 DIGIDRIVERIP DIGISTRIPIP50 DIGISTRIPIP100 4 CONNECTION DIAGRAM Red 3 4 1 2 Green Blue Black 1 Red 2 Green 3 Blue 4 Black Male connector Female connector 2cm 2cm 3mm 3mm 100cm 3 4 1 2...

Страница 20: ...ning frequency As a rule clean this product at least twice a month Dust build up reduces light output performance and can cause overheating This can lead to reduced light source life and increased mec...

Страница 21: ......

Страница 22: ...rziale per propri scopi commerciali vietata Al fine di migliorare la qualit dei prodotti la Music Lights S r l si riserva la facolt di modificare in qualunque momento e senza preavviso le specifiche m...

Страница 23: ...roduzione 1 1 DIGIDRIVERIP 1 2 DIGISTRIPIP100 1 3 DIGISTRIPIP50 1 4 Elementi di comando e collegamenti 2 Installazione 2 1 Montaggio 2 2 Distanza massima di cablaggio 3 Funzioni e impostazioni 3 1 Fun...

Страница 24: ...etallici Non smontare e non apportare modifiche all unit Tutti gli interventi devono essere sempre e solo effettuati da personale tecnico qualificato Rivolgersi al pi vicino centro di assistenza tecni...

Страница 25: ...occuparsi di pioggia e umidit CORPO Hardware a bordo Included kit per montaggio rack Corpo corpo in alluminio pressofuso ad alta resistenza Colore nero Altro 2U rack CONTROLLO Controllo unit 20 x DIGI...

Страница 26: ...without cover 263 lm black cover 60 lm flat white cover 202 lm dome white cover 202lm Flusso luminoso without cover 4 320 nit black cover 727 nit flat white cover 1 233 6 nit dome white cover 681 3 L...

Страница 27: ...ut cover 620 lm black cover 101 lm flat white cover 382 lm dome white cover 411lm Flusso luminoso without cover 8 639 7 nit black cover 1 454 7 nit flat white cover 2 467 3 nit dome white milky cover...

Страница 28: ...WERIN PowerCONIN perilcollegamento ad una presa di rete 100 240V 50 60Hz tramite il cavo rete in dotazione 5 POWER OUT PowerCON OUT collegamento per l alimentazione all unit successiva 6 DMX OUT XLR a...

Страница 29: ...ti sul corpo del dispositivo come mostrato in figura 7 Fig 5 2 2 DISTANZA MASSIMA DI CABLAGGIO Distanza massima di cablaggio tra due dispositivi Nessuna distanza massima tra 2 dispositivi purch la dis...

Страница 30: ...e della funzione o l opzione all interno di un menu 3 FUNZIONI E IMPOSTAZIONI 3 1 FUNZIONAMENTO PeraccendereilDIGIDRIVERIP inserirelaspinadelcavodialimentazioneinunapresadirete 100 240V 50 60Hz L unit...

Страница 31: ...rt A Art Net Kling Net sACN Default Art Net Port B Art Net Kling Net sACN Default Art Net 5 DISPLAY INVERSE No Yes Default No 6 FACTORY RESET No Yes Default Off 7 PORT A Personality 7 CH Drive 8 CH Fi...

Страница 32: ...5 Section 50 Section PixelTOPixel Default PixelTOPixel Net 0 127 Default 0 Subnet 0 15 Default 0 Universe 0 15 Default 0 sACN Universe 1 247 Default 1 IP Address IP Address 1 IP Address 10 Art net IP...

Страница 33: ...Auto 6 Auto 7 Auto 8 Auto 9 Auto 10 Auto 11 Auto 12 Auto 13 Auto 14 Auto 15 Auto 16 Auto 17 Auto 18 Auto 19 Auto 20 Auto 21 Auto 22 Auto 23 Auto 24 Auto 25 All Auto Auto 1 25 000 010 011 020 021 029 0...

Страница 34: ...1 Auto 22 Auto 23 Auto 24 Auto 25 All Auto Auto 1 25 000 010 011 020 021 029 030 039 040 048 049 057 058 067 068 076 077 086 087 095 096 104 105 114 115 123 124 133 134 142 143 151 152 161 162 170 171...

Страница 35: ...BACKGROUND STROBE NO Function Slow to Fast Strobe 000 010 011 255 9 BACKGROUND RED 0 100 000 255 10 BACKGROUND GREEN 0 100 000 255 11 BACKGROUND BLUE 0 100 000 255 13 CHANNELS MODE FUNCTION DMX Value...

Страница 36: ...0 100 000 255 15 CHANNELS 5 SECTION FUNCTION DMX Value 15 Ch 1 RED 1 0 100 000 255 2 GREEN 1 0 100 000 255 3 BLUE 1 0 100 000 255 4 RED 2 0 100 000 255 5 GREEN 2 0 100 000 255 6 BLUE 2 0 100 000 255...

Страница 37: ...GREEN 9 0 100 000 255 27 BLUE 9 0 100 000 255 28 RED 10 0 100 000 255 29 GREEN 10 0 100 000 255 30 BLUE 10 0 100 000 255 75 CHANNELS 25 SECTION FUNCTION DMX Value 75 Ch 1 RED 1 0 100 000 255 2 GREEN 1...

Страница 38: ...9 0 100 000 255 147 BLUE 49 0 100 000 255 148 RED 50 0 100 000 255 149 GREEN 50 0 100 000 255 150 BLUE 50 0 100 000 255 300 CHANNELS PixelTOPixel FUNCTION DMX Value 300 Ch 1 RED 1 0 100 000 255 2 GREE...

Страница 39: ...19 DIGIDRIVERIP DIGISTRIPIP50 DIGISTRIPIP100 4 SCHEMA DI COLLEGAMENTO Red 3 4 1 2 Green Blue Black 1 Red 2 Green 3 Blue 4 Black Male connector Female connector 2cm 2cm 3mm 3mm 100cm 3 4 1 2...

Страница 40: ...due volte al mese L accumulo di polvere riduce la luminosit e pu causare il surriscaldamento L utilizzo e l ambiente sono fattori che contribuisco no a determinare la frequenza di pulizia Per la puliz...

Страница 41: ......

Страница 42: ......

Страница 43: ......

Страница 44: ...MUSIC LIGHTS S r l Phone 39 0771 72190 www musiclights it 2019 Music Lights S r l PROLIGHTS un brand di propriet della Music Lights S r l PROLIGHTS is a brand of Music Lights S r l company...