background image

USER MANUAL

REV.02-07/21

English version

ArcPod 

48Q

48x10W RGBW/FC outdoor IP66 LED 

wash light for exterior installations

Содержание ArcPod 48Q

Страница 1: ...USER MANUAL REV 02 07 21 English version ArcPod 48Q 48x10W RGBW FC outdoor IP66 LED wash light for exterior installations ...

Страница 2: ...conomic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document Product user manual can be downloaded from the website www prolights it or can be inquired to the official PROLIGHTS distributors of your territory https www prolights it sales_network html Scanning the below QR Code you will access the download area of the product pag...

Страница 3: ... DMX LINE 10 INSTRUCTIONS FOR A RELIABLE DMX CONNECTION 10 CONNECTION DAISY CHAIN OF THE DMX LINE 10 DMX ADDRESSING 11 7 RDM FUNCTIONS 11 8 OPERATION VIA DATAMASTER 12 RDM SETTING 12 STAND ALONE FUNCTION 13 9 DMX CHARTS 14 10 ACCESSORIES INSTALLATION 18 LENS CODE S27QLENS10 15 25 45 18 LIGHT DIFFUSION FILTER CODE A48QFILTER 19 BARN DOOR CODE S48QBD OPTIONAL 20 11 MAINTENANCE 21 MAINTENANCE AND CLE...

Страница 4: ... are in perfect condition and rated for the current requirements of all connected devices Isolate the fixture from power immediately if the power plug or any seal cover ca ble or other components are damaged defective deformed or showing signs of overheating Do not reapply power until repairs have been completed Refer any service operation not described in this manual to PROLIGHTS Service team or ...

Страница 5: ...rranty T 80 C c Temperature of the external surface The surface of the fixture can reach up to 80 C 176 F during operation Avoid contact with people and materials Maintenance Warning Disconnect the fixture from AC mains power and allow to cool for at least 10 minutes before handling Only technicians who are authorized by PROLIGHTS or Authorised service partners are permitted to open the fixture Us...

Страница 6: ...oducts to which this manual refers comply with 2014 35 EU Safety of electrical equipment supplied at low voltage LVD 2014 30 EU Electromagnetic Compatibility EMC 2011 65 EU Restriction of the use of certain hazardous substances RoHS ...

Страница 7: ...4 7 cm A48QFILTER6010 60 X10 asymmetric light diffusion filter for ARCPOD48Q and ARCPOD96Q 15x44 7 cm A48QFILTER6030 60 X30 asymmetric light diffusion filter for ARCPOD48Q and ARCPOD96Q 15x44 7 cm S27QLENS10 10 lens for SOLAR27Q ARCPOD27Q SOLAR48Q ARCPOD48Q ARCPOD15Q and ARCPOD96Q S27QLENS15 15 lens for SOLAR27Q ARCPOD27Q SOLAR48Q ARCPOD48Q ARCPOD15Q and ARCPOD96Q S27QLENS25 25 lens for SOLAR27Q A...

Страница 8: ...PROLIGHTS ArcPod 48Q 06 2 TECHNICAL DRAWING 584 mm 23 0 in 304 mm 12 0 in 93 mm 3 7 in 190 mm 7 5 in 250 mm 9 8 in Fig 01 Weight 14 kg 30 86 lbs ...

Страница 9: ...re that is approved as a safety attachment for the weight of the fixture to an anchor point on the product main frame Do not use removable parts or weak anchors for secondary attachment Warning When clamping the fixture to a truss or other structure at any angle use clamps of half cou pler type Do not use any type of clamp that does not completely encircle the structure when fastened 584 mm 23 0 i...

Страница 10: ... 1 POWER IN for connection to a mains 100 240V 50 60Hz The max power consumption is 120W 2 DMX IN 3 pole 1 GND 2 sign 3 sign 3 DMX OUT 3 pole 1 GND 2 sign 3 sign 4 POWER OUT power output for connection of multiple units in series Fig 03 1 2 3 4 ...

Страница 11: ... automatically adjusts to any 50 60Hz AC power source from 100 240 Volts If you need to install a power plug on the power cable to allow connection to power outlets install a grounding type earthed plug following the plug manufacturer s instructions If you have any doubts about proper installation consult a qualified electrician The max power consumption is 521W You can link up tp 2 units at 120 V...

Страница 12: ...t to your DMX network it is necessary to use the adapters XLR 5 pin IP67 signal connector supplied with this product CONNECTION DAISY CHAIN OF THE DMX LINE Connect the DMX data output from the DMX source to the product DMX input male connector Run the data link from the product DMX output female connector connector to the DMX input of the next fixture Terminate the data link by connecting a 120 Oh...

Страница 13: ...DM protocol allows data packets to be inserted into a DMX512 data stream without affecting existing non RDM equipment It allows a console or dedicated RDM controller to send commands to and receive messages from specific fixtures The PIDs in the following tables are supported in the product Parameter PID GET SET DEVICE_INFO 0x0060 x DEVICE_MODEL_DESCRIPTION 0x0080 x MANUFACTURER_LABEL 0x0081 x DEV...

Страница 14: ...l distance to less than 60 m 197 ft Otherwise you might need to use an RDM optically isolated signal amplifier RDM SETTING To set the RDM functions with the DATAMASTER follow these steps Turn on the DATAMASTER Select the RDM function Wait the discovering of all units Select the desired unit and press ENTER button Change the value of the desired function The following chart describes the RDM menu t...

Страница 15: ...nual Color or Effect function Select Head 1 Select the desired color or effect with speed The projector where is setted the STAND ALONE values is a MASTER projector If there isn t the DMX controller or the DMX missing this projector will send his STAND ALONE value on the DMX line On others units that will be connected to the same DMX line must NOT be setted the STAND ALONE they will be SLAVE and t...

Страница 16: ...el 5 Ch 7 Ch 10 Ch 1 RED DIMMER DIMMER 2 GREEN RED RED 3 BLUE GREEN GREEN 4 WHITE BLUE BLUE 5 DIMMER SPEED MODE WHITE WHITE 6 STROBE STROBE 7 DIMMER SPEED MODE COLOR MACRO 8 EFFECTS 9 EFFECTS SPEED 10 DIMMER SPEED MODE 9 DMX CHARTS ...

Страница 17: ... 5600k 6000k 6500k 7000k 8000k 9000k 10000k 000 010 011 030 031 050 051 070 071 090 091 110 111 130 131 150 151 170 171 200 201 205 206 210 211 215 216 220 221 225 226 230 231 235 236 240 241 245 246 250 251 255 000 8 EFFECTS No Function Effect 1 Effect 2 Effect 3 Effect4 Effect5 Effects1 4 Effect 6 Effect 7 Effect 8 Effect 9 Effects6 8 000 010 011 037 038 064 065 091 092 118 119 145 146 172 173 1...

Страница 18: ...STROBE 4 6 GREEN 2 RED 1 7 BLUE 2 GREEN 1 8 WHITE 2 BLUE 1 9 RED 3 WHITE 1 10 GREEN 3 RED 2 11 BLUE 3 GREEN 2 12 WHITE 3 BLUE 2 13 RED 4 WHITE 2 14 GREEN 4 RED 3 15 BLUE 4 GREEN 3 16 WHITE 4 BLUE 3 17 DIMMER SPEED MODE WHITE 3 18 RED 4 19 GREEN 4 20 BLUE 4 21 WHITE 4 22 DIMMER SPEED MODE ROW SECTIONS ROW 1 ROW 2 ROW 3 ROW 4 ...

Страница 19: ...000 4 9 WHITE 1 0 100 000 255 000 5 10 RED 2 0 100 000 255 000 6 11 GREEN 2 0 100 000 255 000 7 12 BLUE 2 0 100 000 255 000 8 13 WHITE 2 0 100 000 255 000 9 14 RED 3 0 100 000 255 000 10 15 GREEN 3 0 100 000 255 000 11 16 BLUE 3 0 100 000 255 000 12 17 WHITE 3 0 100 000 255 000 13 18 RED 4 0 100 000 255 000 14 19 GREEN 4 0 100 000 255 000 15 20 BLUE 4 0 100 000 255 000 16 21 WHITE 4 0 100 000 255 ...

Страница 20: ... the screws Then remove the front glass 2 rubber seal 3 lens holder 4 and the lens 5 2 Replace the lenses by inserting the two pins on the back of the lens DETAIL with the holes pro vided on the PCB LED 5 NOTE to reassemble the lenses reverse the procedure NOTE it is recommended to tighten the front cover screws carefully so as to guarantee the correct IP degree Fig 09 ...

Страница 21: ... front cover 1 by loosing the screws Then remove the front glass 2 and the rubber seal 3 Place the light diffusion filter 4 on the lenses 5 NOTE to remove the light diffusion filter reverse the procedure NOTE it is recommended to tighten the front cover screws carefully so as to guarantee the correct IP degree Fig 10 ...

Страница 22: ...1 2 Insert the two marked pin on down edge of the barn door into the holes provided on the unit 1 and positioning the spring pin on the hardware into the hole provided on the top 2 3 4 Hook the safety cable 3 and adjust the angle of the four leafs 4 Fig 11 ...

Страница 23: ...d according to various factors such as the amount of the use and the condition of the installation environment It is recommended that the product is subject to annual service by a qualified technician for special maintenance involving at least the following procedures General cleaning of internal parts All other service operations on the product must be carried out by MUSIC LIGHTS its approved ser...

Страница 24: ...rs and connect them directly together to bypass one product at a time until normal operation is regained Once found the error have that fixture serviced by a qualified technician Timeout error after fixture reset One or more hardware components requires mechanical adjustments Check product stored error messages for more information Contact MUSIC LIGHTS Service or an authorized service partner Mech...

Страница 25: ...Note ...

Страница 26: ...Note ...

Страница 27: ......

Страница 28: ...PROLIGHTS is a trademark of MUSIC LIGHTS S r l musiclights it prolights it support prolights it Via A Olivetti snc 04026 Minturno LT ITALY Tel 39 0771 72190 ...

Отзывы: