Projoy Prosol-M600 Скачать руководство пользователя страница 7

 

 

7

 

3. PREPARE FOR INSTALLING 

 

3.1 TRANSPORT AND INSPECT 

Projoy packages and protects individual components using suitable means to make the 
transport and  subsequent  handling  easier. Transportation  of the equipment,  especially 
by  road,  must  be  carried  out  by  suitable  ways  for  protecting  the  components  (in 
particular,  the  electronic  components)  from  violent,  shocks,  humidity,  vibration,  etc. 
Please dispose the packaging elements in appropriate ways to avoid unforeseen injury. 

It  is  the  customer’s  responsibility  to  examine  the  condition  of  the  components 
transported. Once receiving the Micro-inverter, it is necessary to check the container for 
any  external  damage  and  verify  receipt  of  all  items.  Call  the  delivering  carrier 
immediately  if  damage  or  shortage  is  detected  .If  inspection  reveals  damage  to  the 
inverter,  contact  the  supplier,  or  authorized  distributor  for  are  pair/return  determination 
and instructions regarding the process. 

 

 

 

3.2 CHECK INSTALLATION ENVIRONMENT 

Installation of the equipment is carried out based on the system design and the place in 
which the equipment is installed. 

  The  installation  must  be  carried  out  with  the  equipment  disconnected  from  the 

grid(power  disconnect  switch  open)  and  with  the  photovoltaic  modules  shaded  or 
isolated. 

  See  Appendix:  Technical  Data  to  check  the  environmental  parameters  to  be 

observed (degree of protection, temperature, humidity, altitude, etc.) 

  To avoid unwanted power derating due to an increase in the internal temperature of 

the inverter, do not expose it to direct sunlight. 

  To  avoid  overheating,  always  make  sure  the  flow  of  air  around  the  inverter  is  not 

blocked. 

  Do not install in places where gasses or flammable substances may be present. 

  Avoid  electromagnetic  interference  that  can  compromise  the  correct  operation  of 

electronic equipment. 

 

 

 

 

Содержание Prosol-M600

Страница 1: ...V1 1 1 User Manual MICRO INVERTER Prosol M600 PROJOY ELECTRIC SRL...

Страница 2: ...BLY INSTRUCTION 10 Step 1 Install Micro inverter 10 Step 2 Connect AC Cable of Micro inverter 10 Step 3 Protecting Unused Ends 10 Step 4 Connecting AC TRUNK Cables to Junction Box 11 Step 5 Drawing Sy...

Страница 3: ...everal inverters this system is built for the incorporation of a Micro inverter for each photovoltaic module Each Micro inverter works independently of the others to guarantee maximum power of each ph...

Страница 4: ...ion that can result in deadly electric shock hazards other serious physical injury or fire hazards Indicates directions which must be fully understood and followed in entirety in order to avoid potent...

Страница 5: ...returned to an author zed dealer or approved collection and recycling facility Caution Do not come within 8 inches 20cm of the micro inverter for any length of time while it is in operation Danger of...

Страница 6: ...nnected in the input of the inverter Do not connect batteries or other sources of power supply The inverter can be used only if all the technical characteristics are observed and applied Do not instal...

Страница 7: ...the inverter contact the supplier or authorized distributor for are pair return determination and instructions regarding the process 3 2 CHECK INSTALLATION ENVIRONMENT Installation of the equipment is...

Страница 8: ...all only on structures specifically conceived for photovoltaic modules supplied by installation technicians Install Micro inverter underneath the photovoltaic modules so that they work in the shade If...

Страница 9: ...STALLING DIAGRAM System Schematic Diagram Fig 2 230Vac single phase Assembly Diagram Fig 3 Assembly Illustration DC AC Red Live Black Neutral Green Ground PV Module Micro inverter AC Cable Junction Bo...

Страница 10: ...cable section The Micro inverter must be under the module out of long term exposure to direct sunlight or rain Step 2 Connect AC Cable of Micro inverter Connect the AC cable of the Micro inverters The...

Страница 11: ...box caps adapters etc must be made with securely sealed Projoy components Projoy AC cables from the Micro inverters have three conductors with different colors to identify the function of each conduct...

Страница 12: ...priate position on the diagram found in the Appendix of this manual Fig 7 System Map Step 6 Install Photovoltaic Modules Install the photovoltaic modules and connect the DC cables of the modules to th...

Страница 13: ...modules so that the Micro inverters can operate in the shade Direct sunlight may cause damage to the Micro inverters Each module must be connected to the Micro inverters with a DC cable having a lengt...

Страница 14: ...igned to allow internal repairs The AC output wiring harness AC drop cable on the Micro inverter cannot be replaced If the cord is damaged the equipment should be scrapped Maintenance operations must...

Страница 15: ...its per 20A Branch 7 Maximum output overcurrent protection A 20 Maximum output fault current ac and duration Efficiency Peak inverter efficiency 96 3 CEC weighted efficiency 95 5 Nominal MPPT efficien...

Страница 16: ...com APAC Branch ProJoy Electric Co Ltd XinTang Industrial Zone PingJiang District Suzhou China Tel 86 512 6878 6489 Fax 86 512 6878 6489 Website www projoy electric com Email Sales projoy electric com...

Отзывы: