 RAM

-4 GB

- 8GB or more

- Virtual Memory: In Win 7, Win 8, Win 10, it is
recommended to use the default option;
"Automatically manage paging  le size for all
drives"

Hard Disk

-30 GB of available hard-disk
space for cache

-Temporary  le cache requires
about 3GB free disk space for
optimal print  le transfers

-SSD or 10,000RPM HDD

Display/GPU

-Open GL 2.1 and GLSL 1.20
enabled graphics card

-Screen resolution 1280x960

-NVidia or AMD GPU with 1GB of RAM or more

-Screen resolution 1280x1024 or higher

Other

-Internet Explorer 9 or newer

-Microsoft .NET Framework 4.5
(installed with application)

-3 button mouse with scroll

-Keyboard

-Google Chrome or Internet Explorer 11

I/O

-Either ethernet or wireless
connection

-Ethernet may be more stable depending on the
facility

Network Interface

The ProJet® 2500 Professional Printing System requires an Ethernet network connection to transfer print jobs from workstation(s) to the printer.

An established TCP/IP network is setup and enabled. An RJ45 Ethernet network connection for each printer to be installed at the delivery site must
be installed, tested and functioning. The printer can use either DHCP or a static assigned IP address. A DHCP server automatically programs an IP
address; otherwise, a network administrator can manually assign a permanent IP address for each printer that is to be connected to the network.
Write IP address(es) here:

___________________________________________________________________

Space Planning

Included in this guide is information and dimensions required to help plan installation of the printer.

Crated Clearance

The 3D printer system is intended to be lifted from the shipping truck using a forklift. Have a forklift available for the 3D Systems Customer Support
Engineer (CSE) or reseller when installation occurs. The crate can then be removed, and the ramps placed as shown below. Store crate pieces where
it will be easy to access should the printer need to be sent back or shipped to another location. Based on the crate size, you must have at least
192”(488mm) (approx. 16’) to accommodate the pallet, ramps and printer, the required footprint to uncrate is approximately 7’ x 16’.(2.13x4.88m)

CAUTION: NEVER unpack, assemble, or connect any component of the shipment without the aid of a quali ed, 3D Systems Customer Support
Engineer or certi ed partner. 3D Systems accepts no responsibility for damaged, defective, or incomplete systems uncrated by anyone other
than 3D Systems Customer Support Engineer or certi ed partner.

Содержание MJP 2500

Страница 1: ...back to http infocenter 3dsystems com projetmjp2500 facility requirements guide for the most up to date facility requirements guide About This Manual This document includes the overall facility requir...

Страница 2: ...Descriptions of hardware software part material networking components and documentation that comprise the ProJet MJP 2500 Professional Printing System An overview of the site requirements in typical e...

Страница 3: ...l before touching Access panels are for service only and should be opened only by certi ed service personnel or trained maintenance personnel THIS GLOBAL HARMONIZED SYSTEM LABEL FOR LOW LEVEL TOXICITY...

Страница 4: ...ontaining the following accessories and materials Two Build Platforms one on the printer and one in an accessory box Region speci c country kit consisting of one power cable Two full cartridges of Vis...

Страница 5: ...oved ____ Network connection s ____ Power outlet s a dedicated circuit to power the 3D printer system ____ Storage cabinetry for extra 3D printer system material containers and other consumables ____...

Страница 6: ...use of a dedicated circuit that will allow for 100 127 VAC 50 60 Hz 15A single phase or 200 240 VAC 50 Hz 10A single phase Single C14 receptacle All ProJet MJP 2500 series printers relies on a connect...

Страница 7: ...about the ProJet XL Finisher click here Client Workstation Requirements Before a print can be printed on the printer the print data le must be saved or exported to the industry standard stl le format...

Страница 8: ...assigned IP address A DHCP server automatically programs an IP address otherwise a network administrator can manually assign a permanent IP address for each printer that is to be connected to the net...

Страница 9: ...rated weight 211kg 465 lbs Floor Flatness Level 2 5cm over 12m 1 over 3 Crate Dimensions and Weight Unit Portability The ProJet 2500 Printing System is equipped with four caster type rollers and four...

Страница 10: ...t of the printer to be able to open the material drawer It is recommended that 36 91cm either behind or in front of the printer for service access Behind would allow service to obtain access from the...

Страница 11: ...cap vented If the warm cartridge is not vented the wax will contract during cooling and the cartridge s bottom may become at which will prevent re engagement in the MDM More detailed information on th...

Страница 12: ...the build process itself can be temperature sensitive within certain limits The operating temperature range should be between 18 28 C 64 82 F optimal temperatures being 18 24 C 64 75 F The facility ai...

Страница 13: ...om your 3 D digital data We are dedicated to developing a relationship that extends beyond the terms of the sale Please take the time to contact 3D Systems with questions comments or suggestions about...

Страница 14: ...e crating location Operating system and workstation con gurations are compatible and meet the minimum requirements as stated in the Client Workstation Requirements section NETWORK CONNECTION IS INSTAL...

Страница 15: ...______________________________________________________________________________ Date _____________________________________________ Please return a copy of the check list by FAXING it to the appropriate...

Страница 16: ...ee Number 800 889 2964 Phone Number 803 326 4080 Web www 3dsystems com Email more info 3d systems com For Customer Support Region Telephone Email North America 800 793 3669 3DWW MJM Customer Support 3...

Страница 17: ..._____ Address _______________________________________________________________________________________ Italy 39 039 68 904 00 39 039 68 811 56 Marketing IT 3dsystems com Japan 03 5451 1690 03 5451 6630...

Страница 18: ...ing the Advance Preparation Checklist Return the completed checklist via the method chosen below Fax to the Account Representative s fax number above Fax to the _______________________________________...

Страница 19: ...t damages arising from the use of this document however caused and on any theory of liability This limitation will apply even if 3D Systems or an certi ed partner or representative has been otherwise...

Отзывы: