background image

9

5.6 

DESCRIPTOR_operations

To aquire the valid range of an operation, set byte 8 (operation type) to 7 (DESCRIPTOR) 
fill in the operation number and send the packet. A successful response will consist of 
PAK (0x1E), followed by the standard 32 bytes. 

5.7 

Example of setting protocol parameters and 

sending a command in CMD window

Setting up the COM port, and sending a “poweron” command, where “poweron” is sim-
ply a binary-file with the appropriate packet for turning the projector on:

This returns, when successful, an acknowledgement as described in chapter 5.2 ,
and turns the projector on.

5.8 

OSD feedback

RS232 control commands will not produce any OSD feedback. Only keypad and IR 
remote control will produce OSD feedback.

5.4 

INCREMENT_  and DECREMENT_operations

These operations are used when you want to increment or decrement the excisting value. 

The response consists of a PAK (0x1E) followed by the initial operation sent, except for 
byte 11, which carries an operation validation code, 0x01. Total packet size is 33 bytes.

5.5 

EXECUTE_operations

An EXECUTE_operation triggers a pre-programmed algorithm in the firmware to execute 
a certain chain of events. The EXECUTE_operation does not contain any parameters to 
indicate a desired value, but simply executes the algorithm assigned to it.

The response is equal to that of the INCREMENT/DECREMENT_operations (see 5.4).

Содержание cineo

Страница 1: ...RS232 and LAN communication protocol...

Страница 2: ...HE PROTOCOL 8 5 2 SET_OPERATIONS 8 5 3 GET_OPERATIONS 8 5 4 INCREMENT_ AND DECREMENT_OPERATIONS 9 5 5 EXECUTE_OPERATIONS 9 5 6 DESCRIPTOR_OPERATIONS 9 5 7 EXAMPLE OF SETTING PROTOCOL PARAMETERS AND SE...

Страница 3: ...ES 28 C 2 1 AUTO ADDRESS MODE 28 C 2 2 FIXED ADDRESS MODE 28 C 2 3 BROADCAST 28 C 3 BAUD RATE 28 C 4 SPECIAL SHORT MESSAGES 29 C 5 EXAMPLES 29 APPENDIX D ADJUSTING CUSTOM COLOR TEMP USING RS232 20 D 1...

Страница 4: ...1 REVISION HISTORY Document Rev Release Date Revised Owner LAN and RS 232 communication protocol and command set 1 0 15 02 06 Initial F3...

Страница 5: ...e same subnet This means that the computer need to have an IP address in the range from 192 168 1 1 to 192 168 1 254 2 SETTING UP LAN COMMUNICATION 2 1 Setting the IP address If you need to change the...

Страница 6: ...by starting up an internet browser like Internet Explorer Opera Firefox or similar Then type the projectors default IP address 192 168 1 90 in the address bar You will then be presented with the logi...

Страница 7: ...e LAN commands is exactly the same as for RS232 control although you may have to pass on the commands to the projector with a different application HyperTerminal that comes with Windows can be used fo...

Страница 8: ...gh 32 Byte 1 is sent first byte 32 last Some columns in Appendix B show the value to be sent for several consecutive bytes These are typically indicated by a range ie 14 16 This means that bytes 14 16...

Страница 9: ...5 8 OSD feedback RS232 control commands will not produce any OSD feedback Only keypad and IR remote control will produce OSD feedback 5 4 INCREMENT_ and DECREMENT_operations These operations are used...

Страница 10: ...tes 6 1 Overview The protocol exists in parallel with the already existing 32 33 byte protocol The protocol has the following definition 6 2 Message body The message body structure is as follows MNEMO...

Страница 11: ...4 bytes 1 byte 6 bytes 1 byte Field Description Comment ACK ASCII character Always SEP ASCII space Always VALUE 6 bytes return value Always TERM Termination char 0x0D CR Always 6 4 Modifier R Relative...

Страница 12: ...Rear Get Set A RCEI Select Orientation Rear Ceiling Get Set A ORIE 0 3 See section 10 Select orientation abs value Get Set A R M N IR01 0 IR Sensor front off Get Set A IR01 1 IR Sensor front on Get Se...

Страница 13: ...CAN 0 Source scan Off Get Set A IVGA Select VGA Get Set A IBNC Select BNC Get Set A IDVI Select DVI Get Set A ISVI Select S video Get Set A ICVI Select Composite video Get Set A IYPP Select Component...

Страница 14: ...2 3 Focus in slow medium fast Set A FOUT 1 2 3 Focus out Set A ZOIN 1 2 3 Zoom in Set A ZOUT 1 2 3 Zoom out Set A IROP 1 2 3 Iris open Set A IRCL 1 2 3 Iris close Set A LSDW 1 2 3 Lens shift down Set...

Страница 15: ...ure Get Set A R M N CTGR Green Color Temperature Get Set A R M N CTBL Blue Color Temperature Get Set A R M N CCXY Select Custom mode Coordinates Get Set A CMXV X coordinate Get Set A R M N CMYV Y coor...

Страница 16: ...2 Select Gamma Video 2 Get Set A GACO 1 Select Gamma Computer 1 Get Set A GACO 2 Select Gamma Computer 2 Get Set A WPEK 0 10 WhitePeaking Get Set A R M N VHUE Hue video Get Set A R M N VKEY Vertical...

Страница 17: ...D Select Video Type DVD Get Set A VVCR Select Video Type VCR Get Set A STATUS FMMA Fan main RPM Get A FMLM Fan lamp 1 RPM Get A FMDM Fan ballast 1 RPM Get A FMLS Fan lamp 2 RPM Get A FMDS Fan ballast...

Страница 18: ...A 2 fill aspect ratio 3 fill 16 9 9 letterbox to 16 9 10 letterbox subtitle to 16 9 13 zoom only Video 14 anamorphic 16 cinemascope ORIE 0 3 0 Desktop front 0 Normal everything OK 1 Ceiling rear 2 Des...

Страница 19: ...acknowledges are marked with green color They can will not be received if acknowledge is turned OFF see section 6 The protocol accepts one single SPACE between fields or no SPACE between fields POWER...

Страница 20: ...R I G 0 0 0 0 6 0 CR 045 BRIG 000034CR INCREMENT value CONTRAST C N T R R 1 CR CNTR R1 0x0D ACKNOWLEDGE CONTRAST INCREMENT 0 0 1 C N T R 0 0 0 1 8 0 CR 001 CNTR 000180CR DECREMENT value CONTRAST C N T...

Страница 21: ...R I G 0 0 0 0 5 0 CR 123 BRIG 000050CR DECREASE value CONTRAST BY 21 C N T R R 2 1 CR CNTR R 21 0x0D ACKNOWLEDGE CONTRAST DECREASE 0 0 1 C N T R 0 0 0 1 7 9 CR 001 CNTR 000179CR INCREASE value CONTRA...

Страница 22: ...sult in poor picture quality and is not recommended ORIE 0 3 0 Desktop front 1 Ceiling rear 2 Desktop rear 3 Ceiling front Command AMX Crestron Power ON POWR1 0d POWR1 r Power OFF address 100 20 POWR...

Страница 23: ...IPTOR 9 10 Operation Number Operation ID 11 Operation Validation Operation is valid return only 12 n a not available for use 13 16 n a not available for use 17 18 Operation Value Value to SET or the v...

Страница 24: ...0x9C 0x02 0x00 0x00 0x00 0x00 0x00 0x00 Select Scaling 1 1 0xBE 0xEF 0x03 0x19 0x00 0x55 0xB2 0x01 0x16 0x44 0x00 0x00 0x00 0x00 0x00 0x00 Select Scaling 16 9 0xBE 0xEF 0x03 0x19 0x00 0xA4 0xF2 0x01 0...

Страница 25: ...0x00 0xD5 0xE8 0x01 0xC7 0x02 0x00 0x00 0x00 0x00 0x00 0x00 Freeze Frame On 0xBE 0xEF 0x03 0x19 0x00 0xFA 0x76 0x01 0x0B 0x44 0x00 0x00 0x00 0x01 0x00 0x00 Freeze Frame Off 0xBE 0xEF 0x03 0x19 0x00 0...

Страница 26: ...BE 0xEF 0x03 0x19 0x00 0xFA 0xDF 0x04 0x1C 0x40 0x00 0x00 0x00 0x00 0x00 0x00 Horizontal Keystone Increment 0xBE 0xEF 0x03 0x19 0x00 0x8A 0x44 0x03 0x21 0x02 0x00 0x00 0x00 0x00 0x00 0x00 Horizontal K...

Страница 27: ...s Decrement 0xBE 0xEF 0x03 0x19 0x00 0x7A 0x11 0x04 0x07 0x40 0x00 0x00 0x00 0x00 0x00 0x00 Green Contrast Increment 0xBE 0xEF 0x03 0x19 0x00 0xD4 0xCA 0x03 0x08 0x40 0x00 0x00 0x00 0x00 0x00 0x00 Gre...

Страница 28: ...E 0xEF 0x03 0x19 0x00 0x6C 0x73 0x02 0x5C 0x03 0x00 0x00 0x00 0x00 0x00 0x00 Lamp Power 2 Get 0xBE 0xEF 0x03 0x19 0x00 0x4D 0xAA 0x02 0xB8 0x0B 0x00 0x00 0x00 0x00 0x00 0x00 EXECUTE Auto Adjust 0xBE 0...

Страница 29: ...osition in the chain The first projector has address 1 the second has address 2 and so on C 2 2 Fixed address mode In fixed mode each projector needs to be programmed with a unique fixed address ir re...

Страница 30: ...bytes 20 33 in the response All other message types can be used C 5 Examples All available RS232 operations are described in Appendix C and apply to the 32 bytes non address protocol To use with the a...

Страница 31: ...ong 33 bytes address message and corresponding short 19 bytes address message Note that the CRC is not in use and can be left 0x00 Byte 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 17 18 19 Select vga1 0xBA 0x...

Страница 32: ...00 00 00 00 D 2 Adjust the color temperature by using the increment decrement operations Red Temp Increment BE EF 03 19 00 14 2B 03 16 40 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00...

Страница 33: ...opped E 1 OSD Warning On When enabling OSD Warnings after beeing disabled OSD is still disabled and must be set to ON to become visible again E 2 Lamp Ignition states 00 Lamp does not ignite 01 Lamp i...

Страница 34: ...34 This page is left blank intentionally...

Страница 35: ......

Отзывы: