2. KEY FEATURES AND FUNCTIONS

AC MAINS

X

X

SOLAR

X

X

AUXILIARY

X

X

DOMINATING SOURCE

AC MAINS

AC MAINS

AUX

Table 3 Source priority

Figure 6  
Charging Algorithm

Icc is the rated current.

2.2 Battery Charger Of Stationery/Service Battery

The charger automatically starts when the appropriate qualified power is connected, either from grid, generator or solar. 
With multiple charging stages (soft start-bulk absorption float-recycle), PM200 is designed to fully charge battery quickly. To guarantee 
the optimal charging for batteries of different states, the PM200 features Microprocessor-controlled charging algorithm. The Float and 
Recycle charging programs guarantees that the battery condition does not change despite being connected for a longer period.

Battery temperature compensation charging

The BTS PM30 (Battery Temperature Sensor) supplied with PM200, measures the temperature of the battery and automatically adjusts, in real 
time, to charge the battery properly at compensation rate of – 4mv±10%/°C/cell. In case BTS is not present, the PM200 will use 25°C as default. 

Voltage compensation charging

With a voltage sensor PM30 the PM200 can, if required, automatically adjust its output to compensate the voltage drop caused by a cable. 
This assures the right voltage is being delivered for optimal charging. 

Adjustable charging capacity 

Users can adjust the charging current by specifying the battery capacity. The charging current is set at threshold rate of 10% the of the 
battery capacity (I = 0.1C) by default. 

Lithium battery charging

The PM200 can be configured to charge Lithium battery. With the Lithium battery, the max charging current will automatically be set at 
30% of battery capacity (Imax=0.3C).

2.3 Vehicle Battery Charger

Along with a powerful charger for service battery, PM200 offers a float charge of up to 3A to keep the starter battery charged, whether 
connected to the AC main or PV. When starter battery is less than 12.4V, the PM200 starts charging after 30 minutes delay and stops 
charging when voltage reaches 12.8V.

2.4 Power Supply Mode

If no battery is attached to PM200 unit, it will work as a power supply automatically with a 12.8VDC output.

7

½ lcc

lcc

11.5V

10 days

1 hr

5mins

SOFT START

STAGE

CURRENT

VOLTAGE

BULK

ABSORPTION

FLOAT

RECYCLE

1

2

3

4

5

1

SOFT START

  

Increases battery life by gently starting to charge the battery 5% of bulk

2

BULK 

Reduces charging time by delivering maximum charge to set voltage life 

by gently starting to charge the battery 25% of bulk

3

ABSORPTION

 

Ensures a full charge to the battery without overcharging  

4

FLOAT 

Float charge maintains the battery at 100% charge

5

RECYCLE

2.1 Multiple Inputs

PM200 master power unit may have many 
sources at one time. These sources include the AC 
mains, solar panel and starter battery (Auxiliary). 
Only one of them will be dominated to provide 
power at one time, even if all are available, 
priorities are listed to the right.

Содержание INTELLI-RV PM200

Страница 1: ...INTELLI RV 12V POWER MANAGEMENT SYSTEM P No PM200 ...

Страница 2: ...ection to supply mains is to be in accordance with National wiring rules Do not attempt to charge non rechargeable batteries Never charge a frozen battery If theAC cord is damaged do not attempt to use It must be replaced or repaired by a qualified person Corrosive substances may escape from the battery during charging and damage delicate surfaces Store and charge in a suitable area Ensure all veh...

Страница 3: ... switch 8 2 10 Silent mode 8 3 STRUCTUREAND INSTALLATION 9 3 1 PM200 Master Power Unit 9 3 2 L E D Display 10 3 3 Water tank probe 11 3 3 1 PMWS400 water tank probe 11 3 3 2 PMWS200 water tank probe 11 4 WIRING 12 4 1 Material 12 4 2 System Schematic 12 4 3 Preparation 13 4 4 Connection 13 5 DISPLAY 14 5 1 PM200 master power unit 14 5 2 L E D Display 15 6 OPERATION 16 6 1 Configuration on PM200 16...

Страница 4: ...n easy installation and a user friendly interface SYSTEM COMPONENTS 1 PM235 Master power unit 2 PMSWLED LED Display 3 PMWS200 or PMWS400Water tank sensor Not supplied 4 Cables Refer to Chapter 4 1 for the cable list 4 FreshWaterTank Probe Not supplied P no PMWS200 or PMWS400 TapWaterTank Probe Not supplied P no PMWS200 or PMWS400 WasteWaterTank Probe Not supplied P no PMWS200 or PMWS400 Service Ba...

Страница 5: ...troller PWM 30A 14 built in outputs 14 built in fused outputs Charging fromAlternator at 12V 60A 60A continuously 100A 30mins Battery LowVoltage Protection Built in battery switch to isolate the battery when in storage Support external remote battery switch Built in shunt for precise battery measurement 1 water pump control with up to 3 connections for water sensors Thermal controlled fan Spring t...

Страница 6: ...Load DC load control Load control on off control Refer to 2 7 4 Fresh water tank Sensor Detect the level of fresh water tank 5 Tap water tank Sensor Detect the level of tap water tank 6 Waste water tank Sensor Detect the level of waste water tank 7 Starter battery Voltage Detect the voltage of starter battery 8 Service battery Voltage Detect the voltage of service battery NO LABEL COLOUR STATUS DE...

Страница 7: ... charging current by specifying the battery capacity The charging current is set at threshold rate of 10 the of the battery capacity I 0 1C by default Lithium battery charging The PM200 can be configured to charge Lithium battery With the Lithium battery the max charging current will automatically be set at 30 of battery capacity Imax 0 3C 2 3Vehicle Battery Charger Along with a powerful charger f...

Страница 8: ...BLE LOAD SUITABLE ClassA1 1 Relay controlled output with fuse protected by main master switch relay Water pump Class B 10 Fused outputs protected by master switch relay Ventilation fan etc Class C 2 Live load Fridge security alarm etc Class D 1 Permanent on load Auto step 2 5 PWM Solar charger controller PM200 has a built in PWM charger for the service battery Max input voltage 25VDC Max charging ...

Страница 9: ...12 Starter Bat Starter battery Connect to starter battery 13 Service Bat Service battery Connect to service battery 14 Starter Bat Starter battery Connect to starter battery 15 Service Bat Service battery Connect to service battery 16 L1 Step Connect to load of class D 17 L2 L3 Connect to load of class C 18 L4 L10 Connect to load of class B 19 L11 Water pump Connect toWater pump 20 L12 L14 Connect...

Страница 10: ...can be installed on a horizontal surface or vertically on a wall Please see following instructions Figure 10 Installation of PM235 unit mm Ensure clearance on both sides of PM235 unit upon installation A recommended clearance of 5cm on each side Figure 9 Dimension of PM235 unit mm ...

Страница 11: ...nk Probe 3 3 1 PMWS400WaterTank Probe Figure 13 Dimension of PMWS400 Unit mm Figure 14 Installation of PMWS400 11 3 3 2 PMWS200WaterTank Probe Installation Figure 15 Dimension of PMWS200 Unit mm Figure 16 Installation of PMWS200 Installation Installation ...

Страница 12: ...er tank level sensor 0 6 5 Waste water tank level sensor 0 7 6 PV 0 9 CODE NAME MODEL LENGTH QTY P NO ON DRAWING 7 Switch panel line 5m 1 PMSWLEDC 8 Battery sensor line 3m 1 PMBS 9 Water tank probe line 4m 0 PMWS200 PMWS400 10 Water tank probe line 4m 0 11 Water tank probe line 4m 0 12 Power Cable 1 5m 1 PMAC Table 6 Components list of PM200 4 2 System Schematic Solar Switch Panel PMWS200 PMWS400 ...

Страница 13: ...nal and cable gauge Figure 18 PM235Terminal TYPE TERMINAL MODEL NUMBER SUITABLE CABLE GAUGE Type 1 ERTB10 10 16 0 5mm2 10mm2 Type 2 wago804 114 0 25mm2 2 5mm2 Figure 19 Connection ofTerminalType 1 13 When running cables if they pass through panels or wall ensure the cables are protected from damage by sharp edges In such cases it is recommended to use cable glands TYPE 1 TYPE 2 Figure 20 Connectio...

Страница 14: ...second The input voltage of the PV is normal but it is charged by theAC or Starter battery Quick flashing flash twice every second PV input error OFF PV disconnected 4 CHG GREEN ON Battery charged Flashing flash once every second Battery charging Slow flashing 1 second on 2 seconds off Battery discharge OFF Battery disconnect 5 FAULT RED ON Short circuit 1 flash Service battery voltage low 2 flash...

Страница 15: ...ank Sensor Detect the level of waste water tank 7 Starter battery Voltage Detect the voltage of starter battery 8 Service battery Voltage Detect the voltage of service battery NO LABEL COLOUR STATUS DESCRIPTION 1 Mains Green ON Battery charged or power supply mode Flash Battery charging under grid electricity OFF NOAC input 2 PV Green Solid Battery charged Flash Battery charging under solar energy...

Страница 16: ...h Table 15 Factory default setting DIP SWITCH 1 2 3 4 STATUS OFF OFF OFF OFF Factory default setting Configure the max charging current of PM235 Configure the battery type connected DS1 DS2 BATTERY CAPACITY CHARGING CURRENT OF PM235 ON ON 50Ah 5A ON OFF 100Ah 10A OFF ON 150Ah 15A OFF OFF 200Ah 20A When choosing max charging current please take into consideration the consumption of the DC load conn...

Страница 17: ...h on PM235 unit works Remote The remote switch works and local one is disabled Figure 24 Local Remote Select Switch Table 16 Local Remote Setting Local Remote 6 1 2 Select Battery Switch Local Remote This function offers a possibility for user to use a remote battery switch to power on off the service battery output It is recommended to switch off the local Battery Switch on main panel of PM200 ma...

Страница 18: ...or 16 0V while AC power is connected 3 PV GREEN Quick flashing flash twice every second Solar input voltage error Solar input 25Vdc 4 Fuse L E D Red OFF Fuse blown need to check load and replace fuse 5 FAULT RED ON Short circuit 1 flash Service battery voltage low 2 flash Service battery voltage height 3 flash Over temp heat sink 4 flash Bulk charge timeout 5 flash VCR anomaly 6 flash Over temp en...

Страница 19: ... current 35A Continuous Efficiency 88 Working temperature 40 C 65 C 50 C full load 60 C 20A 65 C shutdown the output MODEL PM235 OTHERS Battery Disconnect LVD Disconnect voltage AGM GEL WET 10 5VDC default LiFePO4 11 2VDC Default Delay off time 60 sec Reconnect voltage AGM GEL WET 11 5VDC default LiFePO4 12 2VDC Default Current draw on battery 240VAC is off no vehicle charging 405mA LVD battery 10...

Страница 20: ... purchase together with an explanation in writing as to the nature of the claim In the event that the claim is determined to be for a minor failure of the product then BWI reserves the right to repair or replace it at its discretion In the event that a major failure isdetermined the consumer will be entitled to a replacement or a refund as well as compensation for any other reasonably foreseeable ...

Отзывы: