11
* When the PM100 detects the voltage of the starter battery is below 2V, it assumes that
starter battery is not connected to our system.
Mains
Power supply mode (PS mode)
Battery charger mode (CH mode)
Str Bat. Charge Fault
Description
AC grid is working as the source of power supply.
No starter battery connected
"Charge" flashes once every sec.
No starter battery connected.
Absorption charging by Mains Grid.
"Charge" flashes once every sec.
Starter battery has been connected.
Absorption charging by Mains Grid.
Floating charge by Mains Grid.
No starter battery connected.
Floating charge by Mains Grid.
Starter battery has been connected.
"Charge" flashes as 1sec on then 2 secs off.
Mains Grid is not available,10.5V
≤
Service battery voltage <16V.
No Starter battery connected
"Charge" flashes as 1sec on then 2 secs off.
“
Starter Bat.
”flashes twice every sec .
Mains Grid is not available,10.5V
≤
Service battery voltage <16V.
VCR doesn't charge because of the voltage of starter battery
doesn't meet the requirements.
"Charge" flashes once every second.
Mains Grid is not available.
The engine is charging the service battery via VCR.
AC grid is working as the source of power supply.
Starter battery has been connected.
Solutions
4. Display explanation and Troubleshooting
Illuminating
Dim
Flash