STEP 5 – SET CHARGE RATE

The charge rate should be set according to the size of the battery. See the recommended 
charge rates for various battery sizes in the table below.  
(Not all ouputs are available on all models)

a. Press the CHARGE RATE button. The LCD screen will flash the present setting.
b. Press the CHARGE RATE button repeatedly until desired setting is displayed.
c. Wait for the LCD screen to stop flashing.

Note: 

Failure to wait for the screen to stop flashing will cause the charge rate to default 

to previous setting.

ADJUSTABLE CHARGE RATES: 12 VOLT BATTERIES

CHARGE RATE 

BATTERY SIZE (12V)

 

Deep Cycle (AH)   Automotive (CCA)   Marine (MCA)   Time (Hours)  Lithium (AH)  Time (Hours)

2 Amp  

14–40  

80–240  

110–330  

7–24 

4–20 

2–10

6 Amp  

40–120  

240–720  

330–1000  

7–24 

12–60 

2–10

8 Amp  

40–160  

240–1000  

330–1300  

7–24 

16–80 

2–10

12 Amp 

80–240  

480–1440  

660–2000  

7–24 

24–120 

2–10

16 Amp  

110–320  

660–1900  

930–2700  

7–24 

32–160 

2–10

25 Amp  

170–500  

1000–3000  

1400–4200 

7–24 

50–250 

2–10

35 Amp  

240–700  

1440–4200  

2000–5800  

7–24 

70–350 

2–10

50 Amp  

350–1000  

2100–6000  

2900–8300  

7–24 

100–500 

2–10

ADJUSTABLE CHARGE RATES: 24 VOLT BATTERIES (IC8-24)

CHARGE RATE 

BATTERY SIZE (24V)

 

Deep Cycle (AH)   Automotive (CCA)   Marine (MCA)   Time (Hours)  Lithium (AH)  Time (Hours)

2 Amp  

14–40  

80–240  

110–330  

7–24 

4–20 

2–10

4 Amp 

30–80 

180–480 

250–650 

7–24 

8–40 

2–10

6 Amp  

40–120  

240–720  

350–1000  

7–24 

12–60 

2–10

8 Amp  

60–160  

360–1000  

500–1300  

7–24 

16–80 

2–10

STEP 6 – SET BATTERY CHEMISTRY TYPE

Battery Chemistry should be selected by the type of battery being charged (refer to the 
battery manufacturer’s specifications for battery type). Refer to page 5 for a detailed 
explanation.
For example, if you are charging an AGM battery, then AGM mode will need to be 
selected. This can be done by the following procedure:

a. Press the BATTERY TYPE button. The LCD screen will flash the present setting.
b. Press the BATTERY TYPE button repeatedly until desired setting is displayed.
c. Wait for the LCD screen to stop flashing.

Note:

 Failure to wait for the screen to stop flashing will cause the charge rate to default 

to previous setting.

Содержание INTELLI-CHARGE IC25

Страница 1: ...INTELLI CHARGE 7 STAGE SWITCHMODE BATTERY CHARGER P No s IC25 IC25W IC25RV IC35 IC50 IC8 24...

Страница 2: ...a qualified person Corrosive substances may escape from the battery during charging and damage delicate surfaces Store and charge in a suitable area Ensure all vehicle accessories including lights he...

Страница 3: ...ntains the battery at 100 charge VOLTAGE CURRENT AMPS DESULPHATION The Desulphation stage is designed to break down sulphation occurring in batteries that have been left flat for extended periods of t...

Страница 4: ...smallest 1 Amp unit up to the largest 50 Amp offering world class electronics guarantee the battery receives the ultimate charge to ensure maximum life and performance over the life of the battery Th...

Страница 5: ...VOLTS This charge mode is designed for GEL batteries and has a maximum charge voltage of 14 1V Note that some GEL batteries require a higher charge voltage such as 14 4V The AGM mode can be used if t...

Страница 6: ...he temperature sensor monitors the battery temperature and adjusts compensates the charger s output to prevent overcharging This is ideal for batteries used in warmer climates or environments SWITCHMO...

Страница 7: ...s into the mounting surface as per the below illustration Drill a 15mm cable exit hole into the mounting surface ensure cable exit hole is positioned directly in the middle of the mounting plate Posit...

Страница 8: ...K CHARGE POWER ON POWER ON FULLY CHARGED RECON CHARGE BAT TYPE VOLT AMP ABSORB POWER ON BULK CHARGE FULLY CHARGED RECON CHARGE BAT TYPE VOLT AMP ABSORB POWER ON C VOLT AMP POWER ON BULK CHARGE FULLY C...

Страница 9: ...settings to best suit your battery The function of each button is explained below 1 VOLT AMP Change LCD screen display from battery voltage to input current 2 CHARGE RATE Set the charge rate to suit...

Страница 10: ...charging LED LED SIGNAL STAGES OF CHARGING Desulphation Soft Start Bulk Absorption Analysis Recondition Float Equalisation Bulk Charge Fast Flash Slow Flash Solid On Slow Flash Blue Absorption Solid O...

Страница 11: ...onnecting to battery Step 2A Connecting to a battery that is out of the vehicle Step 2B Connecting to a battery fitted to a vehicle Step 2C Permanent hard wiring connection to a battery STEP 2A BATTER...

Страница 12: ...CHARGE RATE BATTERY TYPE RECONDITION VOLT AM P POWERON ABSORPTION BULK CHARGE FULLY CHARGED IC35 12V35A7 STAGE I N T E L L I C H A R G E 1 2 V 3 5 A B A T T E R Y C H A R G E R Connection in vehicle n...

Страница 13: ...DC leads are cut ensure that the sensor wires are included in both positive and negative connections 2 Connect a circuit breaker or inline fuse to the RED Positive lead include sensor wire if DC lead...

Страница 14: ...r Cable length 4 5 metres Warning Ensure the cable is secured safely away from moving parts Installing Temperature Sensor To install the temperature sensor insert the plug into the temperature sensor...

Страница 15: ...0 1400 4200 7 24 50 250 2 10 35 Amp 240 700 1440 4200 2000 5800 7 24 70 350 2 10 50 Amp 350 1000 2100 6000 2900 8300 7 24 100 500 2 10 ADJUSTABLE CHARGE RATES 24 VOLT BATTERIES IC8 24 CHARGE RATE BATT...

Страница 16: ...green FULLY CHARGED LED will illuminate This is known as the float stage and the charger can be left connected to the battery without over charging If the red POWER LED is flashing or the LCD screen d...

Страница 17: ...tion the LCD screen will display rapid horizontal lines Upon completion of the recondition the charger will proceed to carry out a normal charge on the battery STEP 3 Follow STEPS 7 to 9 of the Chargi...

Страница 18: ...OTP Fast Flashing The charger has overheated and has switched off Ensure adequate ventilation around the charger OLC Fast Flashing Sensor wires are not connected to the positive negative connections...

Страница 19: ...75A up to 16V 2 0 5 25A up to 16V 2 0 7 5A up to 16V 2 0A up to 32V then hold for 1 hour then hold for 1 hour then hold for 1 hour then hold for 1 hour or 12 hour timeout or 12 hour timeout or 12 hour...

Страница 20: ...RECONDITION OFF 12V 25A 7 Stage POWER ON BULK CHARGE ABSORPTION FULLY CHARGED TEMPERATURE SENSOR REMOTE ON VOLTS AMPS CHARGE RATE BATTERY TYPE RECONDITION OFF 12V 35A 7 Stage POWER ON BULK CHARGE ABSO...

Страница 21: ...rt to charge the battery and the booster cables can be removed Q Can I use the charger as a power supply A Power Supply mode is designed to operate as a float charge to maintain a battery when running...

Страница 22: ...alled Equalisation This consists of a constant current being fed into the battery until 16 Volts 12V or 32 Volts 24V is reached This rejuvenates the battery cells This charging stage can take up to 12...

Страница 23: ...23 NOTES...

Страница 24: ...of purchase together with an explanation in writing as to the nature of the claim In the event that the claim is determined to be for a minor failure of the product then BWI reserves the right to rep...

Отзывы: