2.2.2 CHARGE FUNCTION MODES

 

It is possible to store the last function modes, so they are immediately available 
after any switching ON/OFF.

 

 

2.2.2.1 STORING PULSE-TRONIC CHARGE

  

Storage of voltage and type of battery, charge mode. 

 Procedure: 
 

–  Check that the charge clamps are not connected to a battery; 

 

–  Connect the power cable to the mains socket; 

 

–  Set the desired charge mode; 

 

–  Disconnect the power cable from the mains socket.

 

 

2.2.2.2 STORING SUPPLY/DIAGNOSTIC MODE

 

 

Storage of delivered voltage and current. 

 Procedure: 
 

–  Set the chosen mode and adjust the voltage/current values as required; 

 

–  Turn on the lock settings by pressing, at the same time, both keys 

 

  “BATTERY VOLTAGE” (fig.A.21) and “CHARGE RATE”(fig.A.23) for  

 

  3 seconds, on the display (fig.A.2)(fig.A. 4) will appear “LOK on.”

 

15Ah 100Ah 300Ah

 

 

15Ah 100Ah 300Ah

DISPLAY

  

80Ah

75Ah

70Ah

. . . . .

. . . . .

100Ah

95Ah

90Ah

CHARGE

RATE

MODE

BATTERY VOLTAGE

Ah SETTING – EXAMPLE

END OF CHARGE – EXAMPLE

 

Battery Type (T) 

Battery Current (C)

 AUTO 

Auto 

   

Auto Boost 

   

Manual ‘Ah’

 AUTO 

Auto 

   

Auto Boost 

   

Manual ‘Ah’

  WET, GEL, AGM, PdCa 

Auto 

   

Auto Boost 

   

Manual ‘Ah’

Содержание HDBM4000

Страница 1: ...6 12 24V 40A 8 STAGE AUTOMATIC CHARGER BATTERY MANAGER WORKSHOP P No HDBM4000...

Страница 2: ...with National wiring rules Do not attempt to charge non rechargeable batteries Never charge a frozen battery If the AC cord is damaged do not attempt to use It must be replaced or repaired by a quali...

Страница 3: ...arge Page 14 2 2 2 2 Storing Supply Diagnostic Mode Page 14 2 3 Battery and Alternator Test Page 15 2 3 1 Battery Test Page 15 2 3 2 Charge System Test Alternator Page 16 2 3 3 Battery Starting Charge...

Страница 4: ...maximum rate constant current to a set voltage at which point the battery is approximately 80 charged STAGE 5 Absorption stage charges the battery to 100 by adjusting the charge rate allowing the bat...

Страница 5: ...type GEL AGM WET and Calcium This ensures correct and thorough charging and maximises battery performance and battery life The following section describes the charge profiles for each chemistry type M...

Страница 6: ...ges Absorption AUTO 7 2V 14 4V 28 8V AUTO i 7 7V 15 4V 30 8V GEL 7 2V 14 4V 28 8V AGM 7 35V 14 7V 29 4V WET 7 7V 15 4V 30 8V Calcium 8 0V 16 0V 32 0V Float Voltage 6 7V 13 5V 27 0V Back Drain 20mA 50m...

Страница 7: ...e selected for the Supply Diagnostic Equalization programs interface messages for the operator alarm codes 3 Polarity inversion short circuit worn out or faulty battery alarm 4 Set current voltage and...

Страница 8: ...tomatic charge mode 17 Pulse Tronic charge 18 Alternator Test Function 19 Battery starting capacity test 20 Battery charge status test 21 BATTERY VOLTAGE Settings button Battery voltage 6 12 24V Silen...

Страница 9: ...lamps refer to the instructions below 1 Remove the M6 Dome head bolt from the clamp 2 Fit the lug on the end of the charging lead to the battery clamp 3 Tighten the lug 1 3 1 CABLE CALIBRATION the pos...

Страница 10: ...utton Battery Voltage after 7 2 OPERATING INSTRUCTIONS Follow the instructions in the order given below 1 Remove the battery covers if present so that the gas produced during charging can exit 7 230V...

Страница 11: ...es Diagnostic and Powersupply mode When finished using the charger 6 Disconnect the battery charger by removing the power cable from the mains socket 7 Disconnect the black charge clamps from the vehi...

Страница 12: ...recommended when there is no information on the battery type b AUTOMATIC PULSE TRONIC AT LOW TEMPERATURES COLD fig A 7 T AUTO d C AUTO Mode that improves the battery charge when the temperature is ve...

Страница 13: ...e battery pay special attention to the technical specifications given by the manufacturer The PULSE TRONIC charge process fig A 17 starts when the display stops flashing each individual phase is ident...

Страница 14: ...e desired charge mode Disconnect the power cable from the mains socket 2 2 2 2 STORING SUPPLY DIAGNOSTIC MODE Storage of delivered voltage and current Procedure Set the chosen mode and adjust the volt...

Страница 15: ...e tests type selection is made after connecting the clamps to the battery terminals 2 3 1 BATTERY TEST Measure the voltage of the batery terminals Procedure press the MODE button fig A 22 to select th...

Страница 16: ...select the battery voltage fig A 1 switch on the engine taking it to approx 1500 rpm switch on all the lights full headlights courtesy lights etc and all the accessories at maximum level air condition...

Страница 17: ...on the display fig A 2 press the BATTERY VOLTAGE button fig A 21 to select the battery voltage fig A 1 start the engine check the display fig A 2 to read the battery starting capacity and the followin...

Страница 18: ...lock the setting by simultaneously pressing and holding the BATTERY VOLTAGE fig A 21 and CHARGE RATE fig A 23 buttons for 3 seconds and fig A 2 fig A 4 LOK on and LOK off will appear respectively on t...

Страница 19: ...ig A 10 press the BATTERY VOLTAGE button fig A 21 to select the battery voltage fig A 1 connect the clamps to the battery terminals the process starts automatically with a variable duration depending...

Страница 20: ...ctory default voltage value is respectively 6 8V 13 6V 27 2V The set voltage mode will be exited automatically after a 3 time out Procedure press the MODE button fig A 22 to select this function fig A...

Страница 21: ...E fig A 21 and CHARGE RATE fig A 23 buttons for 3 seconds and fig A 2 fig A 4 LOK on and LOK off will appear respectively on the display TO EXIT THE ADVANCED PROGRAMS MENU Press and hold the MODE butt...

Страница 22: ...s technical specifications to prevent damage to the on board electronics and the battery Customising VOLTAGE and CURRENT VOLTAGE press and hold simultaneously the BATTERY VOLTAGE fig A 21 and MODE bu...

Страница 23: ...e last operation 2 5 2 SUPPLY Constant voltage generator that can be used on BATTERY CHANGES or on batteries with a very low voltage below 2V to try to increase their voltage to a value that is suitab...

Страница 24: ...dure Press the MODE button fig A 22 to select the SUPPLY function fig A 12 if necessary or requested by the vehicle manufacturer specifications customise the voltage and or current values as indicated...

Страница 25: ...ion connect the vehicle battery terminal clamps the flashing message Go appears on the display fig A 1 now start the vehicle a 30 second timer will engage and will appear on the display fig A 1 at the...

Страница 26: ...C charge has not completed Soft Start within the 4 hour time limit The battery may not be recoverable AL5 PULSE TRONIC charge has not completed bulk charge within the 18 hour time limit The battery ma...

Страница 27: ...tteries with this condition will not recover Q What is a Faulty Cell A 12 Volt batteries contain 6 cells and one faulty cell is enough to ruin your battery If after eight hours of charging your batter...

Страница 28: ...must deliver the product at their cost to the original place of purchase or to any other place which may be nominated by either BWI or the retailer from where the product was bought in order that a wa...

Отзывы: