background image

12x8

Evolution My Den

Building Instructions

Cover Size:

Please read the instruction carefully

and retain for future reference 

For Queries and Help please contact 01777 802300

Please note that all images are for illustration purpose only.

V1.1 17.09.21 INS0149 

12x8 My Den

Double Doors - Metal Roof

Building shown

Содержание Evolution My Den 12x8

Страница 1: ...Please read the instruction carefully and retain for future reference For Queries and Help please contact 01777 802300 Please note that all images are for illustration purpose only V1 1 17 09 21 INS0...

Страница 2: ...oof position 728mm 1000mm 1220mm 1220mm 1220mm Back Panels position Front Panels position 610mm 610mm Double Doors Panel 317 5mm 317 5mm 1220mm 1220mm 1220mm 1220mm LOW 1220mm LOW Gable Window LEFT Ga...

Страница 3: ...oof Section 728mm Width Roof Section 1000mm Width Rear Frame Standoff Gable Frame Standoff Plain Panel 1200mm WIDTH Plain Panel Back RIGHT 1000mm WIDTH Front Monopitch Ridge Flashing Back Water Deflec...

Страница 4: ...m x 2452mm 2 Parts List required ID PT25385 ID PT25398 ID 20931 Base Module fixing Side Front Back Module A 1220mm x 2528mm x 3 A A A ID PT25385 1 Side 1220mm Base Module Pilot drill holes before fixi...

Страница 5: ...le Bearer Base Module fixing Side Front Back Position the gable bearers each side to the fully assembled base Secure with 70mm screws Base Module fixing 70mm Screws ID PT25398 Check the base module ca...

Страница 6: ...Left and Right And secure the plinth lengths together at the corner Pilot drill holes before fixing Floor Stages 70mm Screws ID 15602 ID 15992 ID 15606 Fix the Floors together Floor Stages Side Front...

Страница 7: ...g Left Gable Panel HIGH 1 4 Gable Cloaking Strip 1 60mmx16mmx2050mm Parts List required ID PT25533 ID PT25544 16mm 2094mm 1220mm Lining Flush Back Panel LEFT Diagram Left Gable Panel LOW Diagram 16mm...

Страница 8: ...nel Position ID PT25544 ID PT25523 Back Side LEFT Lining Flush Gap this side LEFT Gable Low Panel Stage ID PT25533 50mm Screws Side LEFT Pilot drill holes before fixing Cloaking Strip is used to fix t...

Страница 9: ...Cloaking Strip 2 60mmx16mmx2050mm Parts List required ID PT25537 ID PT25545 Back Panel RIGHT Diagram Back Panel CENTRE Diagram 16mm 2055mm 1220mm Lining Flush 74mm 1146mm 2055mm 1220mm Lining Flush 5...

Страница 10: ...e the Back Centre Panel Back CENTRE Panel Stages ID PT25537 74mm 1220mm Back Panel Left 1220mm Back Panel Right 1220mm Back Panel Centre Back Panels Position ID PT25544 ID PT25545 ID PT25537 Back Posi...

Страница 11: ...el HIGH Diagram Right Gable Panel LOW Diagram ID PT25535 ID PT25522 50mm Screws Back Side RIGHT Position and fix the side Plain Gable Panel right Pilot drill holes before fixing Right Gable Low Panel...

Страница 12: ...lining board gap can fit in the front corners of the building Plain Panel Front Corner Diagram ID PT25540 Front Side Right Position the front Corner Panel RIGHT to the side gable panels Check the corn...

Страница 13: ...holes before fixing Position the Top Panel and secure in place Top Panel Stage ID PT20324 Front Position and align the Glazing Unit Glazing Unit fixing ID PT18490 Front 50mm Screws Pilot drill holes...

Страница 14: ...e Door Panel Diagram 50mm Screws Front Position the Door Panel and secure in place Pilot drill holes before fixing Double Door Panel fixing ID PT25539 40 Front S70 S70 S70 S70 Secure the Door Panel an...

Страница 15: ...x and secure the UPVC Double Door section to the double door panel UPVC Double Door fixing ID 19504 80mm Screws Front Fix and secure the UPVC Door Cill to the double door panel UPVC Double Door fixing...

Страница 16: ...The panel can be rotated so the lining board gap can fit in the front corners of the building Plain Panel Front Corner Diagram ID PT25540 50mm Screws Front Pilot drill holes before fixing Position and...

Страница 17: ...Stage ID PT25540 70mm Screws Front Pilot drill holes before fixing Top Panel fixing Top Panel Stage S70 S70 S70 S70 S70 S70 Fix the Front Corner Panel and the Glazing Unit Use 70mm Screws through the...

Страница 18: ...5mm Corner Trim 80mm Screws Front Side Front Side ID PT21080 50mm Screws Back Position and fix the Drip Edge Flashing L2530mm x 2 Flashing overlap Drip Edge Flashing Stages Pilot drill holes before fi...

Страница 19: ...of section and insecure to fit underneath to the wall panels Secure the metal roof the wall panels with metal screws Use Step ladder when fixing the roof sections 2 people are required Screws must fix...

Страница 20: ...ide 1m Wide 1m Wide Metal Roof Wall Panels 115mm Metal Roof Screw Ensure the 115mm metal roof screws fix through to the wall panels Metal Roof Cross Section Diagram 65 Roof Section Stages 115mm Metal...

Страница 21: ...s stage Position the 1m wide roof section and slot it into the first roof section Fix in place with metal roof screws 115mm Metal Roof Screws ID 21140 Barge Board Flashing Stages Position the Barge Bo...

Страница 22: ...onopitch Ridge Flashing Stages ID PT21166 Insulation Kits fixing Fit the top architrave over the battens on the window frame Secure the architrave using panel pins See top window architrave detail ID...

Страница 23: ...g panel pins See side window architrave detail ID 21090 Insulation Kits fixing Fit the edge frames around the door frame using Panel Pins ID 21090 Insulation Kits fixing Fix the skirting boards around...

Страница 24: ...mm Black Screws Back Position and fix in place the Guttering Kit on the back of the building Gutter union Guttering fixing ID 20131 ID 20132 Insulation Kits fixing Fix the cladding cover strips over t...

Отзывы: