15
11. Color Measurement
*1 Camera Log conversion
When shooting with Log mode of the camera, you can select the corresponding Log conversion LUT,
to convert the log mode video to standard ITU Rec.709 mode to monitor. A”User-Log” is provided for
user defined LUT converting to Rec.709.
*2 Color measurement
Set the Color measurement parameter to “On” before color calibration, make sure the parameter set to
“Off” after color calibration. When reboot, the Color measurement parameter automatically set to “Off”.
*3 Import 3DLUT cube file
(1) Use a color analysis instrument and calibration software, and set to 6500K, Gamma2.4 for
color calibration, this will generate a correct cube file (recommended Konica Minolta color
analyzer CA-310 and Spectracal CalMAN software);
(2) Rename the cube file to “3DLut.cube” (case matters) , and copy to USB stick;
(3) Insert USB stick to the rear panel of the monitor. Select Operate Menu – Color Measurement –
“Import” – “3DLut.cube” – “Yes” to import
(4) Import user needed Log Lut, User-log file and 1DLut by USB stick.
*4 Reset to factory cubes
For any wrong cubes imported that caused wrong display colors, you can reset the cubes to factory
cubes here.