Important!
Make sure that the gas supply
pressure of the appliance obeys the
recommended values. The adjustable
connection is fixed to the comprehensive
ramp by means of a threaded nut G 1/2"
(NEN 3258). Screw the parts and tighten
everything with teflon tape, if necessary, to
get the right direction.
A
B C
A) End of shaft with nut
B) Washer
C) Elbow
Liquid gas
Use the rubber pipe holder for liquid gas.
Always engage the gasket. Then continue
with the gas connection.
The flexible pipe is prepared for apply
when:
– it can not get hot more than room tem-
perature, higher than 30°C;
– it is no longer than 1500 mm;
– it shows no throttles;
– it is not subject to traction or torsion;
– it does not get in touch with cutting
edges or corners;
– it can be easily examined in order to
make sure its condition.
The control of preservation of the flexible
pipe consists in checking that:
– it does not show cracks, cuts, marks of
burnings on the two ends and on its full
length;
– the material is not hardened, but shows
its correct elasticity;
– the fastening clamps are not rusted;
– expired term is not due.
If one or more defects are visible, do not re-
pair the pipe, but replace it.
Important!
When installation is complete,
make sure that the seal of each pipe fitting
is correct. Use a soapy solution,
not a
flame
!
Injectors replacement
1. Remove the pan supports.
2. Remove the caps and crowns of the
burner.
3. With a socket spanner 7 remove the in-
jectors and replace them with the ones
which are necessary for the type of gas
you use (see table in "Technical Infor-
mation" chapter).
4. Assemble the parts, follow the same
procedure backwards.
5. Replace the rating plate (it is near the
gas supply pipe) with the one for the
new type of gas supply. You can find
this plate in the package supplied with
the appliance.
If the supply gas pressure is changeable or
different from the necessary pressure, you
must fit an applicable pressure adjuster on
the gas supply pipe.
Adjustment of minimum level
To adjust the minimum level of the burners:
1. Light the burner.
2. Turn the knob on the minimum posi-
tion.
3. Remove the knob.
4. With a thin screwdriver, adjust the by-
pass screw position.
A
A) The by-pass screw
• If you change from natural gas G25 25
mbar to liquid gas, fully tighten the ad-
justment screw in.
• If you change from liquid gas to natural
gas G25 25 mbar, undo the by-pass
screw approximately 1/4 of a turn (1/2 of
a turn for Triple Crown burner).
Warning!
Make sure the flame does
not go out when you quickly turn the
knob from the maximum position to the
minimum position.
22
progress
Содержание PAG6430E
Страница 50: ...50 progress...
Страница 51: ...progress 51...
Страница 52: ...www progress hausgeraete de 359064202 B 322012...