Progress Lighting AirPro Verada P2558 Скачать руководство пользователя страница 4

1. 

To reduce the risk of electric shock, insure electricity 

has been turned off at the circuit breaker or fuse box 

before beginning.

2. 

All wiring must be in accordance with the National 

Electrical Code ANSI/NFPA 70-1999 and local electrical codes. 

Electrical installation should be performed by a 

qualified licensed electrician.

3. 

CAUTION: To reduce the risk of personal injury, use only 

the screws provided with the electrical box. 

4. 

The outlet box and support structure must be securely 

mounted and capable of reliably supporting 35 lbs. (15.9 

kg). Use only UL Listed outlet boxes marked “Acceptable 

for Fan Support of 35 lbs. (15.9 kg) or less.”

5. 

CAUTION: The fan must be mounted with a minimum of 

7 feet clearance from the trailing edge of the blades to the 

floor.

6. 

Do not operate reversing switch while fan blades are in 

motion. Fan must be turned off and blades stopped before 

reversing blade direction.

7. 

Avoid placing objects in path of the blades.

8. 

To avoid personal injury or damage to the fan and other 

items, be cautious when working around or 

cleaning the fan.

9. 

Do not use water or detergents when cleaning the fan or fan 

blades. A dry dust cloth or lightly dampened cloth will be 

suitable for most cleaning. 

10. 

After making electrical connections, spliced conductors 

should be turned upward and pushed carefully up into 

electrical box. The wires should be spread apart with the 

grounded conductor and the equipment-grounding 

conductor on one side of the electrical box and ungrounded 

conductor on the other side of the electrical box.

11. 

Electrical diagrams are for reference only. Light kits that 

are not packed with the fan must be UL Listed and marked 

suitable for use with the model fan you are installing. 

Switches must be UL General Use Switches. Refer to the 

instructions packaged with the light kits and switches for 

proper assembly.

12. 

All set screws must be checked and retightened where 

necessary before installation.

13. 

WARNING: To reduce the risk of fire or electric shock, do 

not use this fan with any solid-state speed control device.

1. Safety Rules

READ AND SAVE THESE INSTRUCTIONS

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL 

INJURY, MOUNT TO OUTLET BOX MARKED “ACCEPTABLE FOR FAN 

SUPPORT OF 35LBS. (15.9 KG) OR LESS”, AND USE SCREWS PRO-

VIDED WITH THE OUTLET BOX.

TO REDUCE THE RISK OF PERSONAL INJURY, DO NOT BEND THE 

BLADE BRACKETS (ALSO REFERRED TO AS (“FLANGES”) DURING 

ASSEMBLY OR AFTER INSTALLATION. DO NOT INSERT OBJECTS IN 

THE PATH OF THE BLADES.

Содержание AirPro Verada P2558

Страница 1: ...P2558 93089917_A...

Страница 2: ...r replacement After 30 days the original purchaser MUST contact Progress Lighting at 864 678 1000 for repair or replacement which shall be determined in Progress Lighting s sole discretion and shall b...

Страница 3: ...Safety Rules Unpacking Your Fan Installing Your Fan Making the Electrical Connections Operating Your Fan Care of Your Fan Troubleshooting Specifications Table of Contents 1 2 3 6 9 10 10 11...

Страница 4: ...ry dust cloth or lightly dampened cloth will be suitable for most cleaning 10 After making electrical connections spliced conductors should be turned upward and pushed carefully up into electrical box...

Страница 5: ...y 6 Blades 5 7 Light Kit Pan 8 Light Kit Fitter Assembly 9 Glass Shade 1 Mounting Bracket inside canopy 2 6 Ball Downrod Assembly hanger pin and locking pin pre attached 3 Canopy with Canopy Ring atta...

Страница 6: ...rical box Note You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling The maximum angle allowable is 30 If the canopy touches downrod remove the dec...

Страница 7: ...nrod assembly Figure 7 Remove Loosen but Do Not Remove Turn Canopy Ring to Remove Figure 5 Figure 6 5 Loosen but do not remove the set screws on the collar on the top of the motor housing 6 Align the...

Страница 8: ...on the electrical box by using the mounting screws provided with the electrical box Note that the flat side of the mounting bracket is toward the electrical box Figure 8 3 Tighten the two screws on th...

Страница 9: ...ience have your fan installed by a licensed electrician Follow the steps below to connect the fan to your household wiring Use the wire connecting nuts supplied with your fan and supplied with remote...

Страница 10: ...hing Ceiling Finishing the Fan Installation STANDARD CEILING MOUNTING 1 Align the locking slots of the ceiling canopy with the two screws in the mounting plate Push up to engage the slots and turn clo...

Страница 11: ...e from the light kit fitter assembly by connecting the molded adaptor plugs together Carefully tuck all wires and splices in to the switch cup Figure 14 4 Push the light kit fitter assembly up so that...

Страница 12: ...located at the side of light kit fan refer to figure 13 on page 8 to opposite position and turn fan on again The fan blades will turn in the opposite direction and reverse airflow Figure 17 Figure 18...

Страница 13: ...TION MAKING ELECTRICAL CONNECTIONS Fan will not start Fan sounds noisy 1 Check main and branch circuit fuses or breakers 2 Check line wire connections to the fan and switch wire connections in the swi...

Страница 14: ...LIGHTS WATTS AIRFLOW CFM AIRFLOW EFFICIENCY HIGHER IS BETTER CFM WATT NET WEIGHT GROSS WEIGHT CUBE FEET 52 Low 120 15 1945 130 18 5 Lbs 20 7 Lbs 1 7 Med 32 3054 95 High 65 4445 68 2017 Progress Light...

Страница 15: ...P2558 93089917_A Manual de instalaci n del ventilador de techo...

Страница 16: ...guientes a la compra Pasados 30 d as el comprador original TIENE que contactar a Progress Lighting llamando al 864 678 1000 para reparaci n o reposici n seg n determine Progress Lighting a su entera d...

Страница 17: ...C mo desempacar el ventilador C mo instalar el ventilador C mo hacer las conexiones el ctricas C mo usar el ventilador Cuidado del ventilador Soluci n de problemas Especificaciones Tabla de contenido...

Страница 18: ...pa o seco o ligeramente humedecido con que quitar el polvo 10 Despu s de concluir con las conexiones el ctricas debes voltear los conductores empalmados hacia arriba y empujarlos con cuidado hacia de...

Страница 19: ...orte del kit de luces 9 Pantalla de vidrio 1 Soporte de montaje dentro de la cubierta 2 Conjunto de tubo bajante bola de 6 15 2 cm con pasadores de soporte y de cierre prefijados 3 Cubierta con aro de...

Страница 20: ...alar el ventilador en un techo inclinado El ngulo m ximo permitido es 30 Si la cubierta toca el tubo bajante retira la cubierta inferior decorativa y gira la cubierta 180 antes de fijarla a la placa d...

Страница 21: ...el collar n de la parte superior de la carcasa de motor 6 Alinea los orificios en la parte inferior del tubo bajante con aquellos del collar n en la parte superior de la carcasa de motor Figura 7 Inse...

Страница 22: ...a dentro de la ranura de la bola de soporte Figura 9 Figura 8 Figura 9 Gancho Arandelas AL INSTALAR EL VENTILADOR EN UN TECHO INCLINADO TIENES QUE HACERLO POR EL M TODO DE MONTAJE EST NDAR CON TUBO BA...

Страница 23: ...sa Figura 10 3 Conecta el cable de alimentaci n negro y azul del ventilador al cable de suministro negro del hogar Figura 10 4 Despu s de conectar los cables sep ralos de manera que los cables verde y...

Страница 24: ...tilador funcione por 10 minutos Touching Ceiling C mo finalizar la instalaci n del ventilador MONTAJE EST NDAR EN TECHO 1 Alinea las ranuras de cierre de la cubierta de techo con los dos tornillos de...

Страница 25: ...loca con cuidado todos los cables y empalmes dentro de la caja del interruptor Figura 14 4 Empuja el conjunto del soporte del kit de luces hacia arriba de manera que las cabezas de los dos tornillos a...

Страница 26: ...do en el lado del ventilador del kit de luces consulta la Figura 13 de la p gina 8 hacia la direcci n opuesta y luego vuelve a encender el ventilador Las aspas del ventilador girar n en sentido contra...

Страница 27: ...PRECAUCI N Aseg rate de que la fuente principal de electricidad est apagada 3 Verifica las bater as en el transmisor Se enciende la luz LED roja Est s lo suficientemente cerca del ventilador El rango...

Страница 28: ...FLUJO DEAIRE EN PIES C BICOS POR MINUTO CFM EFICIENCIADE FLUJO DE AIRE MIENTRAS M SALTA MEJOR CFM W PESO NETO PESO BRUTO PIES C BICOS 52 1 32 m Baja 120 15 1945 130 18 5 Lb 20 7 Lb 1 7 Media 32 3054...

Отзывы: