background image

6

  

· 

 

User manual | Weather Station

Sensor configuration

The sensor, with analogue output, acts by delivering a current and a voltage proportional 

to what it measures. The format indicates the sensor units and the relationship between the 
voltage read by the input and the sensor reading values.

To configure the sensors of the weather station, go to:

• 

Function | Settings | Sensors | Analogue

Depending on the controller, once in and for each of the sensors, configure the data according 
to the following tables.

ANALOGUE SENSORS

Configuration

 of the analogue sensors in Agrónic 2500

Sensor

Number

Sensor

Number

Input 

(1)

Number

Input 

(2)

Time

voltage 

(2)

Number

Format

Voltage

(Vdc)

Temperature

1

00001

30101

500 ms

1

12 Vdc

Humidity

2

00002

30102

500 ms

4

Anemometer

3

00201

30103

2 s

5

Wind vane

4

00202

30201

2 s

16

Solar radiation

5

00203

30202

250 ms

2

Connections

The box has a series of connectors prepared and identified to screw in their respective sensors.
The connector layout is as follows:

LEFT PROFILE

RIGHT PROFILE

1

 Configure when the weather station is connected directly to the Agrónic 2500.

2

 Configure in the Agrónic 2500 when the weather station is connected to the AgroBee-L 3MA modules.

Содержание 06730001

Страница 1: ...t connection and is resistant to inclement weather It has a metallic structure to hold the different devices that the weather station includes and arms to place the sensors further away from the body...

Страница 2: ...Grey Solar radiation Green Anemometer Yellow Wind vane White Rainfall gauge A Brown Rainfall gauge B Black Power supply 12 Vdc Blue Power supply 0 Vdc Red Sensor Output signal Reading range Response...

Страница 3: ...ation parts FRONT VIEW REAR VIEW Wind vane Anemometer Main connector Solar Radiation Rainfall gauge Sensor connectors Temperature Relative Humidity Both inside the solar protector Solar protector Anti...

Страница 4: ...metres and about 2 metres Avoid obstacles such as walls trees fences etc that may affect the sensor readings The weather station should be moved away to a reasonable distance of twice the height of th...

Страница 5: ...he inside of the rainfall gauge To do this turn a little to the left as shown in the drawing Lift the aerocone to see the entire rainfall gauge mechanism Use pliers to cut the flange that prevents the...

Страница 6: ...es ANALOGUE SENSORS Configuration of the analogue sensors in Agr nic 2500 Sensor Number Sensor Number Input 1 Number Input 2 Time voltage 2 Number Format Voltage Vdc Temperature 1 00001 30101 500 ms 1...

Страница 7: ...ar Anemometer Wind vane No of integers 3 2 4 3 3 No of decimals 0 1 0 0 0 Sign no yes no no no Units C W m2 km h Calibration Point 1 Real value 800 mV 800 mV 800 mV 800 mV 800 mV Logical value 000 40...

Страница 8: ...o 1 Pulse value 00000 20 L Maximum time between pulses 600 Flow in 000 00 L h Accumulated in 000 00 L m2 Text Rainfall gauge IMPORTANT In the Agr nics 2500 5500 and Bit check that the digital input is...

Страница 9: ...r manual Weather Station 9 Connection examples AGR NIC 2500 BOX MODEL Four analogue inputs Two analogue inputs IMPORTANT Maximum cable length between station and controller 200 m minimum section 0 5 m...

Страница 10: ...10 User manual Weather Station AGR NIC 2500 RECESSED MODEL IMPORTANT Maximum cable length between station and controller 200 m minimum section 0 5 mm2...

Страница 11: ...l Weather Station 11 AGR NIC 4000 In the Agr nic 4000 the rainfall gauge must be connected to digital input number 12 IMPORTANT Maximum cable length between station and controller 200 m minimum sectio...

Страница 12: ...auge Remove the leaf filter and remove any solids that may be clogging it Clean the scoop the funnel hole in the cone and the drains in the base Solar radiation It may be necessary to clean the top do...

Отзывы: