Manual cleaning of spray 

nozzle

- Gently pull out the nozzle and 

apply a

neutral detergent with a soft cloth, sponge
or small brush.

- Gently support

ing

 the nozzle, wipe the

spray tube and nozzle.

Clean

ing the

 filter

Braided hose

Filter

- Make sure that the 

water supply is turned off

 and the power 

is 

off before you clean the filter

.

- Clean the filter when the water flow is less than normal hours.
-

Remove the filter f

rom the water inlet hose

 to clean it.

- Re

-

install the filter in reverse order after cleaning.

Tips: 

- Wipe the product surface with a sponge or soft cloth dampened with 

lukewarm

 

water or a

neutral detergent.

- Lift the upper cover and the seat ring when cleaning 

the toilet bowl

.

- Do not put 

lid/seat

 

down

 

until

 the toilet 

bowl 

is completely 

cleaned

,

 

or

 the 

bidet seat

surfac

e may be 

damaged by

 the cleaning

 chemicals

.

Note: Please 

turn

 off 

the 

power supply before cleaning.

Product surface cleaning

2

A

A

Cleaning & Maintenance

14

Содержание EVO EV105

Страница 1: ...ease read these instructions prior to installation INSTALLATION INSTRUCTIONS USER MANUAL EVO INTELLIGENT BIDET SHOWER SEAT SIDE INLET EV105 T 04 568 9898 E sales plumbline co nz www plumbline co nz Di...

Страница 2: ...p within the warranty period Proof of purchase must be retained Plumbline will also supply parts and labour costs for the replacement or repair of any faulty product within One 1 Year of installation...

Страница 3: ...uct Description 9 Components Description 10 Contents Before use Installation Steps 11 Method of Use 13 Installation and use Cleaning Maintenance 15 Faults Troubleshooting 17 Product Dimensions 18 Prod...

Страница 4: ...idet seat correctly Note the following warnings relevant to safety Prohibited Warning Compulsory Compulsory Note Failure to observe the above mentioned warning signs may result in injury or life threa...

Страница 5: ...electric shock Do not touch the power plug with wet hands Ensure that no water cleaning chemical or urine comes in contact with the power plug May result in fire or electric shock Do not use if socket...

Страница 6: ...arettes or other combustible items near the bidet seat May result in fire May result in product damage Please clean with a diluted kitchen cleaning agent Do not use the following items Benzene paint t...

Страница 7: ...er supply May cause bidet seat failure Do not shower urine on the bidet body and nozzle When not in use for a long time drain the stored water and pull out the power plug May result in water pollution...

Страница 8: ...rol Knob Water supply hose joint Drain plug Power plug Control Knob STOP Bidet Hip washing Water temperature adjustment key Water temperature adjustment indicator Seat temperature adjustment key Seat...

Страница 9: ...Fixing parts Expansion bolt 2 up lock Screw 2 Adjustment sheet 2 Nut 2 down lock Fixing plate 1 Installation Instructions Note There are two installation methods for this product see 3A and 3B on the...

Страница 10: ...sting sheets in the mounting groove align the expansion bolts and tighten the screws 1 Insert the expansion bolts into the holes on the toilet and place the fixing plate in the notch part of installat...

Страница 11: ...ipes 3B Turn on the water supply and check for water leakage Note There are two methods of pipe connecting 1A Turn off the water supply and remove the water supply hose connected to the water tank Con...

Страница 12: ...ter through the control knob hence reducing the washing force Lower body cleaning function bidet washing The control knob is rotated by the vertical gear in the specified direction anticlockwise After...

Страница 13: ...nnot be adjusted when the power supply is cut off but flushing with normal temperature can be used normally OFF Repeatedly pressing will switch over water temperature in the sequence indicated in the...

Страница 14: ...is less than normal hours Remove the filter from the water inlet hose to clean it Re install the filter in reverse order after cleaning Tips Wipe the product surface with a sponge or soft cloth dampe...

Страница 15: ...perature above 0 to prevent the water in the toilet and the water pipe from being frozen Stop using the product and close the water inlet valve when the ambient temperature is below 0 If the bidet sea...

Страница 16: ...eat temperature is set at high gear Adjust seat temperature to lower gear Temperature is too low when making contact with the seat Seat heating function not enabled Cut off power supply and contact an...

Страница 17: ...ontrol Knob to OFF state Surge protector sometimes trips Electricity leakage beyond normal value Cut off power supply stop using product contact and authorised technician Alarm function Product dimens...

Страница 18: ...n valve Water amount regulation Water temperature regulation Heating method Anti backflow device Safety device Temperature fuse and thermal controller Seat heating Surface temperature Heater power 50W...

Отзывы: