10. Loosen the screw to remove the wiring compartment/connection 
cover in the rear of the heater. 
 
 
 
 
 
 
 
 
 
 
11. Run the electrical power supply cable in flexible conduit and 
connect to the wiring compartment via the knock-out at back side of 
the unit. 
12. Make the connections properly with connectors which are 
suitable for the conductor size, including grounding wirings. And after 
making the connections, arrange the pigtail leads of unit and power 
supply wires in the wiring compartment. 
13 You can use the inside or wall thermostat. If you use the inside 
thermostat, press the rock switch to INSIDE THERMOSTAT. 
14 If you want to use the wall thermostat (Not included) , press the 
rock switch to WALL THERMOSTAT, and insert the two wall 
thermostat wire to the Terminal A inside the heater, make sure to 
tighten the screws in the Terminal A. 
 
 
 
 
 
 
 
 
 
15. Replace the wiring compartment/connection cover and lock in 
place with the screw. 
 
 
 

Содержание PH-960XNR

Страница 1: ...f some small pets including birds are extremely sensitive to the fumes produced during the first time use of many appliances These fumes are not harmful to humans but we recommended that you do not us...

Страница 2: ...BLE OF CONTENTS Important Instructions 3 4 Installation Instructions 5 7 Specifications and Wiring Diagram 8 Parts of the heater 9 Operating Instructions 10 Maintenance and Cleaning 12 Troubleshooting...

Страница 3: ...his heater is hot when in use To avoid burns do not let bare skin touch hot surfaces Keep combustible materials such as furniture pillows bedding papers clothes and curtains at least 3 0 9 m from the...

Страница 4: ...o warn that parts of the heater are getting excessively hot If the alarm flashes immediately turn the heater OFF and inspect for any objects on or adjacent to the heater that may have blocked the airf...

Страница 5: ...be connected to individual branch circuit protected by 40Amp circuit breaker only Supply cables must be equipped with a dual pole circuit breaker rating at least 240V 40A pole as main cutoff switch of...

Страница 6: ...fit for the anchor provided for positioning the mounting bracket 6 Insert the anchors 7 Attach the mounting bracket to the wall or ceiling and secure with mounting screws 8 Hook the unit to the mount...

Страница 7: ...wirings And after making the connections arrange the pigtail leads of unit and power supply wires in the wiring compartment 13 You can use the inside or wall thermostat If you use the inside thermosta...

Страница 8: ...L CEILING MOUNTED GARAGE HEATER WITH ELECTRONIC CONTROLLER AND REMOTE Model PH 960XNR Volt 240 V Watts 7500 W Frequency 60 Hz BTU h 25597 Recommended Heating Capacity 1 25 watts ft 0 03m Wiring diagra...

Страница 9: ...ob C Front Exhaust Grill D Louver for air direction E Control panel F Alarm LED G Power Indicator H Timer Indicator I Low Indicator J High Indicator K Inside Wall Thermostat Switch L ON OFF Switch PAR...

Страница 10: ...ower ON OFF device The circuit breaker is to be installed by a certified electrician and shall be located in line of sight from the heater location or shall be capable of being locked in open position...

Страница 11: ...HIGH or LOW heating when the room temperature is equal to or lower than the setting temperature 2 and will turn off when the room temperature is equal to or greater than the setting temperature 2 Not...

Страница 12: ...nce should be performed by qualified service personnel Before any cleaning make sure that 1 Disconnect power supply at source Switch off the circuit breaker 2 Wait for 60 minutes to ensure the heating...

Страница 13: ...ed up to thermostat setting To increase the room temperature adjust thermostat control knob to a higher setting Breaker Fuse has been tripped Check your electrical box to confirm the breaker has not b...

Страница 14: ...14 PLEASE DO NOT ATTEMPT TO OPEN OR REPAIR THE HEATER YOURSELF DOING SO COULD CAUSE DAMAGE OR PERSONAL INJURY...