ProDaylight 800 Air
16
www.profoto.com
Maintenance
Changing lamp
1. Ensure that the ProBallast 800 is turned off and that the Lamp Cable [8] is not
connected.
2. If the ProDaylight 800 Air unit has been in use, wait for the unit to cool down.
3. Unlock the glass cover by pressing the safety pins down and then pulling them one by
one, see figure on page 12.
4. Gently remove the glass cover.
5. Unscrew the two screws and remove the reflector plate.
The glossy side of
the reflector plate
shall face outwards.
6. Pull the lamp straight out of the socket. Always use protective gloves when doing this.
7. Insert a new modeling lamp, straight into the socket. Do not touch the lamp with bare
hands.
8. Fit the reflector plate in place, with the glossy side facing outwards. Tighten the two
screws.
9. Gently fit the fit the glass cover in place.
10. Make sure that the circuit breaker is pressed down and that both safety pins fit properly
into the holes on each side of the glass cover, see figure on page 13.
11. Secure the glass cover by pressing the safety pins down and then pushing them one
by one under the top screw.
Changing fuse
There is one exchangeable fuse in the ProBallast 800.
1. Disconnect the ProBallast 800 from AC mains power.
2. Pull out the Fuse Holder [F] and remove the old fuse.
3. Gently push the new fuse all the way into the Fuse Holder [F]. Only use fuses specified
in section
Technical data
.
4. Gently push the Fuse Holder [F] in place.
SAFETY PRECAUTION!
Do not touch bulb with bare hand. Cleaning
cloth is included with Profoto supplied bulb.