www.profoto.com

SAFETY PRECAUTIONS!

Do not operate the equipment before studying the instruction manual and the accompanying safety. Make 
sure that Profoto Safety Instructions is always accompanied the equipment! Profoto products are intended 
for professional use! Generator, lamp heads and accessories are only intended for indoor photographic 
use. Do not place or use the equipment where it can be exposed to moisture, extreme electromagnetic 
fields or in areas with flammable gases or dust! Do not expose the equipment to dripping or splashing.
Do not place any objects filled with liquids, such as vases, on or near the equipment.Do not expose the 
equipment to hasty temperature changes in humid conditions as this could lead to condensation water 
in the unit.Do not connect this equipment to flash equipment from other brands. Do not use flash heads 
without supplied protective glass covers or protective grids. Glass covers shall be changed if it has 
become visibly damaged to such an extent that their effectiveness is impaired, for example by cracks 
or deep scratches.Lamps shall be changed if they are damaged or thermally deformed.When placing 
a lamp into the holder ensure not to touch the bulb with bare hands. Equipment must only be serviced, 
modified or repaired by authorized and competent service personnel! Warning - The terminals marked 
with the flash symbol are hazardous live.

WARNING – Electrical Shock – High Voltage!

Mains powered generator shall always be connected to a mains socket outlet with a protective earthing 
connection!Only use Profoto extension cables! Do not open or disassemble generator or lamp head! 
Equipment operates with high voltage. Generator capacitors are electrically charged for a considerable 
time after being turned off. Do not touch modeling lamp or flash tube when mounting umbrella metal 
shaft in its reflector hole. Disconnect lamp head cable between generator and lamp head when changing 
modeling lamp or flash tube! The mains plug or appliance coupler is used as disconnect device. The 
disconnect device shall remain readily operable. Batteries (battery pack or batteries installed) shall not 
be exposed to excessive heat such as sunshine, fire or the like.

Caution – Burn Hazard – Hot Parts!

Do not touch hot parts with bare fingers! Modeling lamps, flash tubes and certain metal parts emit 
strong heat when used! Do not point modeling lamps or flash tubes too close to persons. All lamps may 
on rare occasions explode and throw out hot particles! Make sure that rated voltage for modeling lamp 
corresponds with technical data of user guide regarding power supply!

NOTICE – Equipment Overheating Risk

Remove transport cap from lamp head before use! Do not obstruct ventilation by placing filters, diffusing 
materials, etc. over inlets and outlets of the equipment ventilation or directly over glass cover, modeling 
lamp or flash tube!

 

Note about RF!

This equipment makes use of the radio spectrum and emits radio frequency energy. Proper care should 
be taken when the device is integrated in systems. Make sure that all specifications within this document 
are followed, especially those concerning operating temperature and supply voltage range. Make sure the 
device is operated according to local regulations. The frequency spectrum this device is using is shared 
with other users. Interference can not be ruled out.

Final Disposal

Equipment contains electrical and electronic components that could be harmful to the environment. 
Equipment may be returned to Profoto distributors free of charge for recycling according to WEEE. Follow 
local legal requirements for separate disposal of waste, for instance WEEE directive for electrical and 
electronic equipment on the European market, when product life has ended!

Safety instructions

Содержание D4 1200 Air

Страница 1: ...D41200Air D42400Air D44800Air User s Guide...

Страница 2: ...D4 1200 Air D4 2400 Air D4 4800 Air 2 www profoto com...

Страница 3: ...ividual product comply with specified performance quality andsafety Forthisreasonourflashequipmentiswidelyusedin rentalstudiosandrentalhousesworldwide fromParis London Milan NewYork TokyotoCapeTown Pr...

Страница 4: ...le time after being turned off Do not touch modeling lamp or flash tube when mounting umbrella metal shaftinitsreflectorhole Disconnectlampheadcablebetweengeneratorandlampheadwhenchanging modeling lam...

Страница 5: ...ync and control 13 Auxiliary functions 13 Test function 15 Memory function 15 Additional information 16 Color Temperature 16 f stop stability 16 Flash duration 16 Petrol electric generators 16 Operati...

Страница 6: ...om Miscellaneous 23 Measurements 23 Compatible heads 24 Old Profoto heads 24 Warranty 24 Regulatory information 25 World wide Usage of Radio Spectrum 25 EU Declaration of Conformity 25 Unites States a...

Страница 7: ...irectlyandeveryadjustmentisdisplayedimmediately Itis possibletoactivateanddeactivateeachheadseparatelybythepushofabutton TheintegratedAirsystemoffersareliableradiosyncandcomfortableradioremotecontrol...

Страница 8: ...ally or group them to control multiple generators at one time You can save customerlightingsetupsforuseatalatertime TheD4AirgeneratorcanbeconnectedtothePC MaceitherwithaUSBcableorwirelessly viatheProf...

Страница 9: ...veButton 12 Head ModelButtons A D 13 EnergyControls A D 14 MasterButton 15 USBPort 16 ReadyModeIndicators 17 ReadyModeButton 18 ReadyLampandTestButton 19 ModelingLightButton 20 ModelingLightIndicators...

Страница 10: ...age 100V modeling lamps in 100V markets 120V modeling lamps in 110 120V markets and 240V modeling lamps in 200 240Vmarkets PLEASE CHECKTHE CONFIGURATION OFTHE GENERATOR THE MODELING LAMPSAND THEMAINSV...

Страница 11: ...flash to dischargethegeneratorwhentheenergylevelislowered Modelinglight TheHead ModelButtonsA D 12 areusedtoturnon offthecorrespondingmodelinglight TheModelingLightButton 19 isusedtoturnon offallthemo...

Страница 12: ...dicate that the charging of the generator is completed BUZZ An audible signal with several beeps will indicate that the generator is being charged BEEP DIM The modeling light will be turned off while...

Страница 13: ...hronizationandcontrol Forsync controlviaradio theProfotoAirreceiverinthegeneratormustbeactivatedanda radiochannelmustbeselected SeeRemotesync controlsetupinstructionsonpage20 The Profoto Air system op...

Страница 14: ...rements pressdownthecontrolwhileturning Delay Turn Energy Control C 13 to select the delay time 0 1 60 s before the first flash Forchangesinlargerincrements pressdownthecontrolwhileturning Ifoneorseve...

Страница 15: ...tions The D4 Air generator is equipped with an effective cooling and safety system The integrated fan will automatically start running when the generator is operating at higher energylevelsorwhenthege...

Страница 16: ...tialwhenD4Airgeneratorsareused in combination with Multi Shot backs or for 3D pictures The power stability of the D4Air generatorsisinfactbetterthantherepeataccuracyofmostflashmeters Flashduration The...

Страница 17: ...wingthreebuttons theWs f stopButton 11 andtheHead ModelButtonBandC 12 4 Whilestillpressingthethreebuttons connectthepowercabletotheMainsSocket 1 andtoACmainssupply 5 While still pressing the three but...

Страница 18: ...P BUZZ BEEP DIM BUZZ DIM DIMorOFF 4 UsetheRechargingSpeedButton 18 toselectNormal unlitbutton orFast litbutton Rechargingspeed Auxiliaryfunctionssettings 1 Press the Set Button 7 twice The auxiliary f...

Страница 19: ...or sync cord never via the computeranditssoftware Remotesync controlsetup 1 PresstheSetButton 7 oncetoenterauxiliarymode Thegroupsettingforeachhead willbedisplayedintheEnergyDisplays 10 2 TurntheEner...

Страница 20: ...e Ready Lamp 18 will turn off and a double beep signal will confirm that Memory Mode is entered 2 While still holding down the Recall Save Button 11 shortly press the Head Model Button 12 correspondin...

Страница 21: ...tructions onpage18 Thefuseofthelamp headand orthelamp bulbblows Thegeneratoris notconfiguredtobe compatiblewiththe connectedhead Configurethegenerator accordingtotheinstructions onpage17 Oneorseveralm...

Страница 22: ...00Ws SocketC 9 600Ws SocketC 18 1200Ws SocketC 36 2400Ws SocketD 9 300Ws SocketD 18 600Ws SocketD 36 1200Ws AsymmetryRange max7 8f stops Recyclingtime 120V 60Hz 0 07 1 2s 0 09 2 2s 0 12 4 4s Recycling...

Страница 23: ...ons Sequence Interval Delay Miscellaneous DigitalDisplay Yes f stops Ws Auxfunctionsandradiosettings FanCooled Yes temperatureregulated AutomaticMulti Voltage Yes 100 120V 200 240V 50 60Hz ReadySignal...

Страница 24: ...7 heads However Profoto does not recommenduseofoldAcutePABandAcuteAlfaheads ABorABS NOTE Whenequippedwitha220 240V 50Hzmodelinglight PF PB Pro 6andPro 7headscanbeusedat220 240V 50Hz However Profotodo...

Страница 25: ...e Radio and Telecommunications Terminal Equipment Act and Directive1999 5 EC R TTEDirective Manufacturer ProfotoAB Address Box2023 12821SKARPN CK Sweden Product 2 4GHzSRDcommunicationmodule Type Profo...

Страница 26: ...SS 210 d Industrie Canada L utilisation de ce dispositifestautoris eseulementauxconditionssuivantes 1 ilnedoitpasproduiredebrouillageet 2 l utilisateur du dispositif doit tre pr t accepter tout brouil...

Страница 27: ...rationinJapan Classificationofspecifiedradioequipment Article2 Clause1 Item19 2 4GHzWideBandLowPowerDataCommunication 38 24 1 Thisistocertifythattheabove mentionedcertificationbytypehasbeengrantedin a...

Страница 28: ...ProfotoAB P O Box1264 SE 17225Stockholm SWEDEN Phone 4684475300 info profoto com www profoto com V3 Printed in Sweden Technical data and product information are subject to change without notice...