background image

B2 250 AirTTL

14

www.profoto.com

Select ready signal

The current setting is shown in the Ready signal setting section [29]:

• 

BEEP: The unit beeps when it is ready to flash again after recharging.

• 

DIM: The modeling light is turned off after flashing, and is turned on when the unit is 
ready to flash again.

• 

DIM BEEP: The modeling light is turned off after flashing. The modeling light is turned 
on and the unit beeps when it is ready to flash again.

• 

Blank: No ready signal.

To select the ready signal setting, press the READY button [11].

The TEST button [4] is always turned off after flashing, and is illuminated when the B2 is 
ready to flash again.

Turn on/off lamp head

To turn off the lamp head, press the corresponding MODEL button [9] or [12] for one 
second. The lamp head’s light output setting [24] will show ‘- -’ when the lamp head is 
turned off. To turn on the lamp head press the MODEL button once more. 

Wrong exposure alarm

If a flash is released before the unit is ready, there will be a long beep and the display will 
blink. These signals indicate that the flash light does not fully correspond to the set value. 
The B2 will always flash even if the set light output cannot be met, as the image may still 
be usable if the catch of the moment was perfect.

Note that the sound alarm only will be activated when the Ready signal is set to ‘BEEP’ or 
‘DIM BEEP’. 

Quick burst

Quick burst is an automatically activated function that allows a series (burst) of flashes to 
be fired at a faster pace than the B2 can recharge, without losing light output. The function 
is only active when the light output is set to less than full. The length of the burst, in number 
of flashes, depends on the repetition rate and the set light output. The lower the light output 
is set, the more bursts can be triggered. Thanks to this feature, the B2 can trigger several 
flashes on lower power output without triggering the “Wrong exposure alarm”. Note that 
the accuracy of the light output is slightly less precise when Quick burst is active. Quick 
burst is indicated by blinking energy settings.

TTL

Profoto B2 can automatically set flash energy for a perfect exposure. The optional Air 
Remote TTL merge camera and flash into one and controls the flash fully automatically 
without manual metering. Compatible cameras can be found on Profoto.com.

Содержание B2 250 AirTTL

Страница 1: ...ügbarunterprofoto com de support ES Estaguíadeusuarioestádisponibleenotrosidiomasenprofoto com support FR Cemanueld utilisationestégalementdisponibleend autreslanguessurprofoto com fr support IT Questaguidapergliutentièdisponibileinaltrelinguesuprofoto com it support JP このユーザーガイドはprofoto com ja supportに他の言語でもご用意しています RU Инструкция пользователя на других языках доступна на profoto com ru support ...

Страница 2: ...B2 250 AirTTL 2 www profoto com ...

Страница 3: ... Asaresult weareconfidentthatyournewProfotoproductwill staywithyouforyearsandhelpyougrowasaphotographer But getting the product is only the beginning of that journey Using it for light shaping is the real adventure That is why we takeprideinprovidingyouwithsuchawideassortmentoflight shaping tools allowing you to shape the light in any way you canimagine Thealmostinfinitepossibilitiesmightseembewil...

Страница 4: ...atteries installed shall not be exposed to excessive heat such as direct sunlight fire orthelike Safety advices for Lithium Ion batteries Do not crush Do not heat or incinerate Do not short circuit Do not dismantle Do not immerse in any liquid asthismaycausethebatterytoventorrupture Caution Burn Hazard Hot Parts Donottouchhotpartswithbarefingers Modelinglamps flashtubes protectiveglass andcertainm...

Страница 5: ...lect Ready signal 14 Turn On Off lamp head 14 Wrong exposure alarm 14 Quick burst 14 TTL 14 HSS 15 Handling 16 Battery status and charging 16 Battery mounting 16 Stand mounting 16 Mounting Profoto Light Shaping Tools 17 Lamp head connection 17 Extension cable connection 18 Replacement of protective glass flash tube modeling light LED 18 Other 19 Temperature limit indicator 19 Check Firmware 19 Upg...

Страница 6: ...B2 250 AirTTL 6 www profoto com ...

Страница 7: ...Display 6 SYNCbutton 7 SETbutton 8 ONbutton 9 MODELbutton1 10 MODEbutton 11 READYbutton 12 MODELbutton2 13 ENERGY SETTINGSdial1 14 ENERGY SETTINGSdial2 15 16 17 18 19 20 15 Syncconnector 16 USBport 17 Battery 18 Batterychargingconnector 19 BatteryCHECKbutton 20 Batteryreleasebutton 1 2 3 4 5 6 7 8 9 10 11 12 13 14 ...

Страница 8: ...Lightoutputsetting visibleonlywhen lampheadisconnected 25 Sync Airsetting 26 Batterylevelindicator 27 Modelinglightsetting1 28 Modesetting 29 Readysignalsetting 30 Modelinglightsetting2 31 Temperaturelimitindicator 21 22 23 24 25 26 27 28 29 30 31 32 Lampheadplug 33 Protectiveglass 34 Umbrellaholder 32 33 34 ...

Страница 9: ...B2 250 AirTTL 9 www profoto com 35 Standattachmentscrew 36 Tilt lockhandle 37 Clampscrew 38 Standadapter 39 ProfotoBatteryCharger2 8A 37 36 35 38 ...

Страница 10: ...B2 250 AirTTL 10 www profoto com 40 ProfotoCarCharger1 8A optional 41 B2AirTTLExtensionCable3m optional ...

Страница 11: ...ingtheTESTbutton 4 seepage7 10 Turn on off the modeling light of the connected lamp head by the corresponding MODELbutton 9 or 12 seepage13 11 SelectFreeze NormalmodebypressingtheMODEbutton 10 seepage13 12 SelectReadysignalsettingwiththeREADYbutton 11 seepage14 13 MountLightShapingTools seepage17 Poweron off Toswitchon offtheB2unit pressandholdtheONbutton 8 for1second When the B2 unit is switched ...

Страница 12: ...IR isshownintheSync Airsettingsection 25 theB2issettobetriggeredand or controlled from any of the optional ProfotoAir transceivers offered by Profoto The B2 supportsallavailableAiraccessoriesofferedbyProfoto includingthoselistedinthetable below 1 ActivateAirbypressingtheSYNCbutton 6 until AIR isdisplayed 2 Toviewthecurrentchannelsetting presstheSETbutton 7 once Thechannelsetting isdisplayedwithabl...

Страница 13: ...ibleinallsyncmodes Connectasynccablefromthecameraorflash metertotheSyncConnector 15 Modelinglight To turn on off the modeling light on a lamp head press the corresponding MODEL button 9 or 12 Themodelinglightsareautomaticallyturnedoffafterasettableperiodofinactivity 1 30 minutes 1 Tosetthetimer presstheSETbutton 7 until SETTIMER isdisplayed 2 TurntheENERGY SETTINGSdial2 14 tochangethetime SelectFr...

Страница 14: ...ethattheflashlightdoesnotfullycorrespondtothesetvalue The B2 will always flash even if the set light output cannot be met as the image may still beusableifthecatchofthemomentwasperfect Note that the sound alarm only will be activated when the Ready signal is set to BEEP or DIMBEEP Quickburst Quickburstisanautomaticallyactivatedfunctionthatallowsaseries burst offlashesto befiredatafasterpacethanthe...

Страница 15: ...flashoutputisset automatically by the camera The indicator is lit for fifteen seconds after receiving aTTL flashcommandfromtheremote HSS Profoto B2 supports HSS High Speed Sync with the optional Air Remote TTL enabling shutter time faster than the fastest x sync of the camera For compatible cameras visit Profoto com DuringaHSSflash theflashispulsingtogetaconstantlightoutputduringthetimewhen the sh...

Страница 16: ...eavethebatteryunchargedforalongtime Batterymounting 1 To mount the battery fit the battery pack in place and push firmly until the battery pack locks in place Make sure there is a click sound indicating that the battery packisproperlysecured 2 To dismount the battery first switch off the B2 unit Press the battery release button 20 andpulloutthebatterypack Standmounting The B2 lamp heads can be mou...

Страница 17: ...ead 3 Securebylockingtheclaspontherubbercollar Umbrellamounting Umbrellasaresimplymountedbyslidingtheumbrellashaftintotheumbrellaholder 34 Thediameteroftheholderisdesignedfor8mmshafts 1 Slidetheumbrellashaftintotheumbrellaholder 34 2 Afterafewcentimeters therewillbemorefriction Continuetoslidetheumbrellashaft afewmorecentimetersintotheumbrellaholder 34 Lampheadconnection Attention Alwaysremovethep...

Страница 18: ...emale 2 Pushtheplug male allthewayintotheconnector female 3 Securebyturningtheribbedlockingringonthelampheadplugclockwise To protect the connectors of the extension cable it is appropriate to connect the plug to theoutletofthecable Replacementofprotectiveglass flashtube modelinglightLED Forreplacementoftheprotectiveglass flashtubeormodelinglightLED contactyourlocal dealerordistributorforprofession...

Страница 19: ...onthegenerator 8 2 Thecurrentfirmwareversionisshownonthedisplay 5 forexample A7 UpgradeFirmware WerecommendthatyouregularlylookforfirmwareupgradesonProfoto com With a personal account at My Profoto you can register your product and be sure you get noticed when important firmware updates are released Create an account at Profoto com myprofototoregisterandupdateyourproduct Upgradeoffirmwareismadevia...

Страница 20: ...nFreezemode t0 5 1 15000s 1Ws 1 1 000s 250Ws EnergystabilityNormalmode 1 20f stopflashtoflash EnergystabilityFreezemode 1 20f stopflashtoflash ColorstabilityNormalmode 150Koverrange 20Kflashtoflash ColorstabilityFreezemode 800Koverrange 50Kflashtoflash Lightspreadwithbuilt inreflector 70degrees Guidenumber 2m 100ISOwith Magnumreflector 322 10 Battery Model ExchangeableLi Ionbattery4S1P Type PCA132...

Страница 21: ...tedonthedisplay 3sections 100 70 2sections 70 40 1section 40 10 Blinking 10 Batterychargingtime 1h Autopoweroff Yesafter60minutes Sleepmodeactivated after30minutes Wirelesssync Yes viaallAircameratransmittersorIR Slave AllfiguresaretobeconsideredasnominalandProfotoreservestherighttomakechanges withoutfurthernotice ...

Страница 22: ...ceived including interference that may causeundesiredoperation Warning Part 15 21 Changes or modifications not expressly approved by the party responsible for compliance could void the user s authoritytooperatetheequipment Ce dispositif est conforme aux normes RSS 210 d Industrie Canada L utilisation de ce dispositifestautoriséeseulementauxconditionssuivantes 1 ilnedoitpasproduiredebrouillageet 2 ...

Страница 23: ...設備の種類 Classificationofspecifiedradioequipment Article2 Clause1 Item19 2 4GHzWideBandLowPowerDataCommunication 上記のとおり 電波法第38条の24第1項の規定に基づく認証を行ったも のであることを証する Thisistocertifythattheabove mentionedcertificationbytypehasbeengrantedin accordancewiththeprovisionsofArticle38 24 Paragraph1oftheRadioLaw R 202WW08109201 ...

Страница 24: ...B2 250 AirTTL 24 www profoto com ...

Страница 25: ...B2 250 AirTTL 25 www profoto com ...

Страница 26: ...nted in Sweden Technical data and product information are subject to change without notice ProfotoAB P O Box1264 SE 17265Sundbyberg SWEDEN Visitingaddress Landsvägen57 Sundbyberg Phone 4684475300 info profoto com www profoto com ...

Отзывы: