background image

Profoto B1 500 Air TTL

13

www.profoto.com

Wrong exposure alarm

When a flash is released before the unit is ready, there will be a long beep and the display 
will blink. These signals indicate that the flash light does not fully correspond to the set 
value. The B1 will always continue to flash even if the set light output cannot be met as the 
image may still be usable if the catch of the moment was perfect. 

The sound alarm is partially deactivated when BEEP is deactivated. If BEEP is deactivated 
the sound alarm will only go off if B1 is used in TTL operation and cannot keep up with the 
camera in sequence shooting. 

Quick burst

Quick burst is an automatically activated function that allows a series (burst) of flashes to 
be fired at a faster pace than the B1 can recharge, without losing light output. The function 
is only active when the light output is set to less than full. The length of the burst, in number 
of flashes, depends on the repetition rate and the set light output. The lower the light output 
is set, the longer bursts can be triggered. Thanks to this feature, the B1 can trigger up to 20 
flashes per second on lower power output without triggering the “Wrong exposure alarm”. 
Note that the accuracy of the light output is slightly less precise when Quick burst is active.

Содержание B1 500 AirTTL

Страница 1: ...ProfotoB1500AirTTL User s Guide...

Страница 2: ...Profoto B1 500 Air TTL 2 www profoto com...

Страница 3: ...itisano go Asaresult weareconfidentthatyournewProfotoproductwill staywithyouforyearsandhelpyougrowasaphotographer But getting the product is only the beginning of that journey Using it for light shapi...

Страница 4: ...being turned off Do not touch modeling lamps or flash tubes when mounting an umbrella metal shaft in its reflector hole Disconnect the lamp head cable between the generator and lampheadwhenchangingthe...

Страница 5: ...10 Set light output Energy 10 Select Sync setting 11 Modeling light settings 12 Ready signal settings 12 Handling 14 Battery mounting 14 Battery charging 14 Stand mounting 14 Mounting Profoto Light Sh...

Страница 6: ...1 500 Air TTL 6 www profoto com 7 8 9 1 Handle 2 Tilt lockknob 3 Standadapter 4 Clampscrew 5 ReflectorandFrontglass 6 Zoomscale 7 Umbrellaholder 8 Battery 9 Batteryreleasebutton Nomenclature 7 8 9 3 1...

Страница 7: ...foto B1 500 Air TTL 7 www profoto com 10 USBport 11 Syncconnector 12 IR Slaveeye 13 LCDdisplay 14 MODELbutton 15 TESTbutton 16 ENERGY SETTINGSdial 17 READYbutton 18 SYNCbutton 12 11 10 13 14 15 16 18...

Страница 8: ...ting 21 Sync Airsetting 22 Batterylevelindicator 23 Lightoutputsetting 24 Freezemodeindicator 25 Temperaturelimitindicator 26 Automaticflashexposure TTL indicator 27 Batterycharger 28 Case BagXS AIR S...

Страница 9: ...ial 16 andthenshortlypressingtheTESTbutton 15 seepage11 8 SetthebrieflyflashlightoutputwithENERGY SETTINGSdial 16 seepage11 9 ReleaseatestflashbypressingtheTESTbutton 15 seepage11 10 SelectSyncsetting...

Страница 10: ...nd then shortly pressing the TEST button 15 When Freeze mode is selected the Freezemodeindicator 24 isshownontheDisplay 13 SeebelowoverviewofflashdurationinFreezevs Normalmode Setlightoutput Energy Th...

Страница 11: ...1supportsallavailableAiraccessoriesofferedbyProfotoincludingthose listedinthetablebelow 1 ActivateAirbyfollowingtheinstructionstoSelectSyncSetting 2 WhenAir is activated press and hold down the SYNC b...

Страница 12: ...The modeling light intensity is automatically adjusted to be proportional to the selectedenergyleveloftheflashlight FREE The modeling light intensity is manually set independent from the energy level...

Страница 13: ...rmwillonlygooffifB1isusedinTTLoperationandcannotkeepupwiththe camerainsequenceshooting Quickburst Quickburstisanautomaticallyactivatedfunctionthatallowsaseries burst offlashesto befiredatafasterpaceth...

Страница 14: ...ckthatthebatterychargerindicatesthatchargingisinprogress 4 Whenthebatterychargerindicatesthatthechargingiscompleted itisrecommended todisconnectthebatterychargerandremovethebatteryfromthecharger Stand...

Страница 15: ...llaholder 7 ReplacingtheFrontglass TheFrontglass 5 canbereplacedwithoptionalfrontglassorglassdomes Domescan beusedtoenhancethe zoomeffect ifusinganyofProfoto s zoomable reflectors 1 SwitchofftheB1andr...

Страница 16: ...iftheB1hasreachedatemperaturelevelthathas activated the built in over temperature protection When this occurs the performance is limiteduntilthetemperaturelevelisbacktoanacceptablelevel CheckFirmware...

Страница 17: ...s EnergystabilityNormalmode 1 20f stopflashtoflash EnergystabilityFreezemode 1 20f stopflashtoflash ColorstabilityNormalmode 150Koverrange 20Kflashtoflash ColorstabilityFreezemode 800Koverrange 50Kfla...

Страница 18: ...erature range 10 Cto 50 C 4 Fto 120 F Battery storage temperature range 20 Cto 60 C 20 Fto 140 F Wirelesssync Yes viaallAircameratransmittersorIR Slave All figures are to be considered as nominal and...

Страница 19: ...Profoto B1 500 Air TTL 19 www profoto com...

Страница 20: ...ProfotoAB SWEDEN Phone 4684475300 info profoto com www profoto com 344097 A1 Printed in Sweden Technical data and product information are subject to change without notice...