USING THE RESTORATION 2.0

The RESTORATION 2.0 is designed to seat two
adults. The six thera-jets can be regulated to provide
a relaxing massage to sooth away stress, and the
strength of the water massage can be adjusted by the
air control. The RESTORATION 2.0 holds 120 gallons
of water and offers an automatic, programmable heat-
ing (70¡F to 104¡F) and filtration system. 

The guidelines below explain how to properly use the
RESTORATION 2.0. Follow these guidelines to main-
tain the RESTORATION 2.0 for your long-term enjoy-
ment.

PLUGGING IN THE RESTORATION 2.0 

Once the RESTORATION 2.0 is filled with water 

and

you have made sure that the cut-off valves to the
pump are open

, the power cord can be plugged in

and the spa can be turned on. Note: The first time the
power cord is plugged in, the spa will turn on auto-
matically.

When connecting the power cord, plug the power cord
directly into a grounded circuit capable of carrying 15
or more amps. No other appliance should be on the
same circuit. Replace the power cord immediately if it
becomes damaged.

The power cord is equipped with a Ground Fault
Circuit Interrupter (GFCI), located at the end of the
power cord. You should always test the GFCI before
using the RESTORATION 2.0.  

First, turn on the RESTORATION 2.0 by pressing the
power button on the console. Once the unit is run-
ning, press the GFCI ÒtestÓ button. The RESTORA-
TION 2.0 should shut off. Press the ÒresetÓ button.
The RESTORATION 2.0 should resume normal oper-
ation. If the RESTORATION 2.0 continues to run after
the ÒtestÓ button is pressed, then the GFCI is dam-
aged. Do not use the RESTORATION 2.0 until the
GFCI has been repaired or replaced by a qualified
electrician.

TESTING AND TREATING THE WATER

The RESTORATION 2.0 comes with a starter chemi-
cal pack for maintaining the water in the spa.
Disregard the directions on the individual packages of
ÒQUICK pHix It DOWNÓ and ÒQUICK pHix It UP.Ó
However, the directions on the bottle of ÒNon-chlorine
ShoxÓ and ÒBromine BaseÓ are correct. 

Always keep

the chemicals away from children and pets.

The first time you use the spa, you should test and
treat the water. 

You must also treat the water each

time you refill the spa.

Once you have verified that

the spa is functioning properly, and the water has cir-
culated for a while, remove the spa cover and add 1/3
of the ÒBromine BaseÓ bottle, and 1/3 of the ÒNon-
chlorine ShoxÓ bottle to the water. Allow the water to
circulate for five minutes. You should now test the pH
of the water. You will need a pH test kit (not included),
which can be obtained at a pool and spa supply store.
The pH reading should be between 7.2 and 7.8. 

If the level is too low, add half of one of the ÒQUICK
pHix It UPÓ packets to the water. Let the water circu-
late through the spa for five minutes. Test the pH level
again. Repeat until the pH level is correct.

If the level is too high, add half of one of the ÒQUICK
pHix It DOWNÓ packets to the water. Let the water cir-
culate through the spa for five minutes. Test the pH
level again. Repeat until the pH level is correct.

See WATER CHEMISTRY on page 13 for information
concerning proper water maintenance.

STARTING THE RESTORATION 2.0 

Once you have tested the GFCI, you should verify the
water flow from the pumping unit. Set the air control
on the console to the lowest setting (see USING THE
CONSOLE on the next page). The pumping unit will
heat the water as it pumps. Cover the RESTORA-
TION 2.0 with the spa cover. 

The spa cover must be

tight and the insulation blanket in place.

(See

USING THE INSULATION BLANKET and SECURING
THE SPA COVER on page 12.) The water will heat at
about 2.0¡F an hour with the cover on. If you are using
the spa indoors, and the room temperature is main-
tained at 70¡F, it will take approximately 18 to 24
hours for the water to reach the set temperature.

The temperature and water flow can be set or
changed by the controls on the console (see USING
THE CONSOLE on the next page).

Test and Reset

Buttons

Grounded circuit

capable of carrying

15 or more amps

GFCI

Содержание PFHS70071

Страница 1: ...behind the access cover QUESTIONS PLEASE CALL DIRECT TO OUR TOLL FREE CUSTOMER HOT LINE The trained technicians on our customer hot line will provide immediate assistance free of charge to you CUSTOME...

Страница 2: ...ing damage resulting from improper winterization damage to the spa shell resulting from improper chemical treatment damage to the spa shell resulting from exposure to extreme temperatures or damage to...

Страница 3: ...empty The surface of the spa shell can reach temperatures as high as 150 F in a matter of minutes if exposed to the sun while it is empty These high temperatures can cause significant damage such as b...

Страница 4: ...the RESTORATION 2 0 by children Children must always be super vised 28 DANGER To reduce the risk of drowning Never use the RESTORATION 2 0 alone Children should not use the RESTORATION 2 0 unless the...

Страница 5: ...s over the age of 35 or persons with pre existing health problems such as obesity heart disease high or low blood pressure circulatory prob lems or diabetes to consult their physician before using thi...

Страница 6: ...0 gives you the specialized treatment you need to feel your best For your safety and benefit read this manual care fully before using the PROFORM RESTORATION 2 0 If you have additional questions plea...

Страница 7: ...system that is built flush with the top of the spa provided you leave access to the motor for service 9 Be sure to note any other considerations such as aesthetics or privacy concerns which may affec...

Страница 8: ...see step 1 above 3 Wipe out the spa shell using a damp cloth Remove the two warning decals not shown from the spa shell Before you fill the RESTORATION 2 0 be sure that it is in the position you want...

Страница 9: ...Position one of the Buckles 2 on the wood panels on the Spa Unit 15 and hold the Buckle in place so the strap on the Spa Cover 13 is tight Note It may be easier to posi tion the Buckles if a second pe...

Страница 10: ...t UP However the directions on the bottle of Non chlorine Shox and Bromine Base are correct Always keep the chemicals away from children and pets The first time you use the spa you should test and tre...

Страница 11: ...A located on one end of the spa focus the water massage on your back The three multi directional thera jets B can be adjusted for a custom hydro massage One of the jets is located below the three uni...

Страница 12: ...spa cover into the buckles on the side panels The buckles can be locked by inserting the key and turning it clockwise a quarter turn To unlock the buckles insert the key and turn it counter clockwise...

Страница 13: ...THE SPA EXTERIOR The wood panel exterior has been treated with a sealant at the factory to protect the wood from water damage We suggest that you treat the wood finish twice a year with an additional...

Страница 14: ...ore The pH reading should be between 7 2 and 7 8 If the level is too low add a pH increaser usually soda ash If the level is too high add a pH reducer usually sodium bisulfate Test the water again aft...

Страница 15: ...into the closed position and turn the handles until they lock into place If you are planning to work on the pump motor you will also need to drain the pump see page 14 To open the valves turn the han...

Страница 16: ...OT HEAT a The pump in the spa jet unit is the heater If the pump is operating the water should heat Cover the RESTORATION 2 0 with the spa cover The spa cover must be tight with the insulation blanket...

Страница 17: ...s will not function properly 10 SYMPTOM THE WATER LEVEL DROPS a Some water loss due to evaporation is normal If rapid water loss occurs or if you notice wet ness on the floor around the RESTORATION 2...

Страница 18: ...1 Filter Housing 18 1 Housing Ring 19 2 Cover Screws 20 1 Filter Cover 21 1 Filter 22 2 Suction Cover Screw 23 2 Suction Cover 24 1 3 8 Jamnut Key No Qty Description 25 2 Power Supply Mounting Screw...

Страница 19: ...33 32 26 27 36 35 1 2 3 4 5 6 10 11 13 15 2 14 16 44 37 29 28 7 19 20 21 17 18 34 9 25 22 23 22 23 12 30 31 8 38 39 40 41 42 24 EXPLODED DRAWING Model No PFHS70071 R0199A 19...

Страница 20: ...t you please be pre pared to give the following information when calling The MODEL NUMBER of the product PFHS70071 The NAME of the product PROFORM RESTORATION 2 0 Massage Spa The SERIAL NUMBER of the...

Отзывы: