background image

13

HOW TO PLUG IN THE POWER CORD

Your vibration platform, like any other type of sophisti-

cated electronic equipment, can be seriously damaged

by sudden voltage changes in your homeʼs power.

Voltage surges, spikes, and noise interference can

result from weather conditions or from other appliances

being turned on or off.

To decrease the possibility of

your vibration platform being damaged, always

use a surge suppressor with your vibration plat-

form (see drawing 1 at the right). To purchase a

surge suppressor, see your local PROFORM dealer

or call the telephone number on the front cover of

this manual and order part number 146148, or see

your local electronics store.

Use only a single-outlet surge suppressor that is

UL 1449 listed as a transient voltage surge sup-

pressor (TVSS). The surge suppressor must have

a UL suppressed voltage rating of 400 volts or less

and a minimum surge dissipation of 450 joules.

The surge suppressor must be electrically rated

for 120 volts AC and 15 amps. There must be a

monitoring light on the surge suppressor to indi-

cate whether it is functioning properly.

This product must be grounded.

If it should mal-

function or break down, grounding provides a path of

least resistance for electric current to reduce the risk

of electric shock. This product is equipped with a cord

having an equipment-grounding conductor and a

grounding plug.

Plug the power cord into a surge

suppressor, and plug the surge suppressor into an

appropriate outlet that is properly installed and

grounded in accordance with all local codes and

ordinances. IMPORTANT: The vibration platform is

not compatible with GFCI-equipped outlets.

This product is for use on a nominal 120-volt circuit,

and has a grounding plug that looks like the plug illus-

trated in drawing 1 below. A temporary adapter that

looks like the adapter illustrated in drawing 2 may be

used to connect the surge suppressor to a 2-pole

receptacle as shown in drawing 2 if a properly

grounded outlet is not available.

The temporary adapter should be used only until a

properly grounded outlet (drawing 1) can be installed

by a qualified electrician.

The green-colored rigid ear, lug, or the like extending

from the adapter must be connected to a permanent

ground such as a properly grounded outlet box cover.

Whenever the adapter is used it must be held in place

by a metal screw.

Some 2-pole receptacle outlet

box covers are not grounded. Contact a qualified

electrician to determine if the outlet box cover is

grounded before using an adapter.

DANGER:

Improper connection

of the equipment-grounding conductor can

result in an increased risk of electric shock.

Check with a qualified electrician or service-

man if you are in doubt as to whether the

product is properly grounded. Do not modify

the plug provided with the product—if it will

not fit the outlet, have a proper outlet

installed by a qualified electrician.

1

2

Grounded Outlet Box

Grounded Outlet Box

Grounding Plug

Surge Suppressor

Surge Suppressor

Grounding Pin

Adapter

Lug

Metal Screw

Grounded Outlet

Grounding Pin

Содержание ACTIVATOR V5

Страница 1: ...iding complete customer satisfaction If you have questions or if parts are damaged or missing PLEASE DO NOT CONTACT THE STORE please contact Customer Care IMPORTANT You must note the product model num...

Страница 2: ...G REPLACEMENT PARTS Back Cover LIMITED WARRANTY Back Cover 2 WARNING DECAL PLACEMENT The warning decals shown here have been applied in the locations shown If a decal is missing or illegible call the...

Страница 3: ...ge 12 and pets away from the vibration platform at all times 7 The vibration platform should not be used by persons weighing more than 300 lbs 136 kg 8 Never allow more than one person on the vibratio...

Страница 4: ...telephone number on the front cover of this manual and order part number 146148 or see your local electronics store 16 Keep the power cord away from heated sur faces 17 Never leave the vibration plat...

Страница 5: ...the front cover of this manual To help us assist you note the product model number and serial number before con tacting us The model number and the location of the serial number decal are shown on th...

Страница 6: ...10 x 55mm Patch Screw 20 M4 x 16mm Patch Screw 26 M10 x 68mm Bolt 44 6 See the drawings below to identify small parts used in assembly The number in parentheses by each drawing is the key number of th...

Страница 7: ...in a cleared area and remove the packing materials Do not dispose of the packing materials until assembly is completed For help identifying small parts see the PART IDENTIFICATION CHART on page 6 Tig...

Страница 8: ...Orient the Wheel Bracket 35 so that the arrow sticker is pointing upward Attach the Wheel Bracket 35 to the Lower Upright 1 with two M10 x 20mm Patch Screws 28 3 1 5 1 28 35 20 38 4 Attach the Wheel...

Страница 9: ...til the Wire Harness is routed through the Upper Upright 6 Tip Be careful not to pinch the wires during this step Attach the Upper Upright 36 to the Lower Upright 1 with four M10 x 20mm Patch Screws 2...

Страница 10: ...the Console 3 near the Upper Upright 36 con nect the console ground wire to the Ground Wire 41 Next connect the console wire to the Wire Harness 43 Then insert the wires into the Upper Upright 10 3 4...

Страница 11: ...he four M4 x 12mm Self tapping Screws 27 you removed in step 8 and an M4 x 19mm Screw 45 See step 9 Tighten the two M4 x 16mm Patch Screws 26 11 3 27 27 45 3 12 Plug the Power Cord 17 into the Recepta...

Страница 12: ...the handlebar and place one foot against the wheel Tilt the vibration platform until it rolls freely on the wheel Carefully move the vibration platform to the desired location To reduce the risk of i...

Страница 13: ...the surge suppressor into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances IMPORTANT The vibration platform is not compatible with GFCI e...

Страница 14: ...er of this manu al iFIT cards are also available at select stores HOW TO TURN ON THE POWER IMPORTANT If the vibration platform has been exposed to cold temperatures allow it to warm to room temperatur...

Страница 15: ...itional vibration sessions as desired IMPORTANT It is recom mended that you use the vibration platform for no more than 15 minutes per day and no more than 3 times per week 7 When you are finished swi...

Страница 16: ...tlet see page 13 Use only a single outlet surge sup pressor that meets all of the specifications described on page 13 IMPORTANT The vibration platform is not compatible with GFCI equipped outlets b Ch...

Страница 17: ...17 NOTES...

Страница 18: ...ch Screw 29 1 Rubber Spacer 30 1 Wheel 31 4 M4 x 8mm Screw 32 3 M10 Nylon Locknut 33 1 M10 x 114mm Bolt 34 5 M10 x 35mm Screw 35 1 Wheel Bracket 36 1 Upper Upright 37 2 M10 x 62mm Patch Screw 38 8 M10...

Страница 19: ...2 4 6 12 15 14 16 13 9 10 11 36 3 39 48 48 48 34 15 14 16 13 34 20 15 14 16 13 34 16 13 34 5 15 14 48 7 8 22 23 21 25 25 17 43 24 24 24 24 37 27 26 45 27 28 32 35 33 28 29 13 34 18 19 31 47 46 47 46 3...

Страница 20: ...ential damages arising out of or in con nection with the use or performance of the product or damages with respect to any economic loss loss of property loss of revenues or profits loss of enjoyment o...

Отзывы: