background image

Model RMC-FA300PF

11

RMC-FA300PF

ProFitter

TM

 Operating Instructions and Parts Manual

Repair Parts List for Propane Construction Heater

  1 

Inner Shell Assembly 

2315586 

1

 2 

Screw 

2001355 

6

  3 

Frame Holder 

2315587 

1

 4 

Screw 

2001355 

3

 5 

Nut 

2000112 

2

 6 

Sleeve 

2315511 

2

  7 

Thermal Switch 

2201153 

1

 8 

Screw 

2001059 

2

 9 

Nut 

2305686 

1

 10 

Spark Plug Assembly 

2315582 

1

 11 

Bolt 

2001447 

3

 12 

Burner Top 

2315603 

1

 13 

Inner Ring 

2315602 

1

 14 

Burner 

2315601 

1

 15 

Nut 

2000121 

3

 16 

Burner Tube Assembly 

2315600 

1

 17 

Outer Shell 

2315575 

1

 18 

Handle Assembly 

2101447 

1

 19 

Screw 

2000416 

2

 20 

Nut 

2000384 

2

 21 

Motor Assembly 

2315590 

1

 22 

Fan Assembly 

2315592 

1

 23 

Motor Support 

2315584 

1

 24 

Motor Bracket 

2315591 

1

 25 

Fan Guard 

2315500 

1

 26 

Screw 

2001355 

3

 27 

Thermostat Assembly 

2201186 

1

 28 

Screw 

2000375 

2

 29 

Clip 

2301973 

1

 30 

Screw 

2000375 

1

 31 

Nut 

2000231 

1

 32 

Capacitor 

2201586 

1

 33 

Bushing Strain Relief 

2101633 

1

 34 

Power Cord Assembly 

2201163 

1

 35 

Switch 

2201549 

1

 36 

Solenoid Valve 

2315449 

1

 37 

Screw 

2001206 

2

 38 

Connector Inlet 

2315595 

1

 39 

Fitting 

2315596 

1

 40 

Solenoid Valve Bracket 

2315594 

1

 41 

Screw 

2000416 

2

 42 

Nut 

2000384 

2

 43 

Back Pressure Switch 

2201594 

1

 44 

Base Lower 

2315589 

1

 45 

Screw 

2001355 

6

 46 

PCB Assembly 

2201181 

1

 47 

Screw 

2001445 

2

 48 

Nut 

2000231 

2

 49 

Base 

2315588 

1

 50 

Plastic Tube 

2101052 

1

 51 

Aluminum Tube Bracket 

2315700 

2

 52 

Screw 

2001355 

4

 53 

Aluminum Tube 

2315699 

1

 54 

Tubing Assembly 

2315599 

1

 55 

Nozzle Base 

2315598 

1

 56 

Nozzle 

2315597 

1

 57 

Knob 

2101207 

1

   

Regulator & Hose Assembly 

 KR-126-10-31   

 Ref. 

 

Part 

 No. 

Description 

No. 

Qty.

 Ref. 

 

Part 

 No. 

Description 

No. 

Qty.

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

Use only original 
replacement parts. This 
Heater must use design-

specific parts. Do not substitute or use 
generic parts. Improper replacement parts 
could cause serious or fatal injuries.

58

1

10 ft (3m)

KR-126-15-31

Regulator & Hose Assembly
15 ft (4.6m)

E

N
G

L

I

S

H

For Technical Support or Troubleshooting, Call: 1-877-447-4768, 8:30 am - 4:30 pm CST         www.ghpgroupinc.com

Содержание RMC-FA300PF

Страница 1: ...OPERTY LOSS OR DAMAGE FROM THE HZARARDS OF FIRE EXPLOSION BURN ASPHYXIATION CARBON MONOXIDE POISONING AND OR ELECTRIC SHOCK ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTION MANUAL LABELS ETCETERA CONTACT THE MANUFACTURER General Safety Information IMPORTANT Be sure to read and understan...

Страница 2: ...ces a small amount of carbon monoxide Humans can tolerate small amounts of carbon monoxide for short periods Carbon monoxide can build up in a heated space and failure to provide adequate ventilation could result in poisoning or death For either indoor or outdoor use Adequate ventilation shall be provided in accordance with OSHA 29 CFR 1926 154 Safety Requirements for Temporary and Portable Space ...

Страница 3: ... SAFETY CONTROL SYSTEM This system shuts the heater down if the flame is extinguished The fan and motor will continue to operate butthere will not be any heat PROPANE SUPPLY All propane gas and tanks are to be provided by the user This heater should only be used with a tank that has a vapor withdrawal system Refer to the Standard of Storage and Handling of Liquefied Petroleum Gas ANSI NFPA 58 Chap...

Страница 4: ...ns Correct all leaks immediately 7 Close propane supply valve Ventilation Always follow the minimum fresh air ventilation requirements If these guidelines are not followed carbon monoxide poisoning can occur Always provide proper amounts of fresh air before operating this heater Provide at least three square feet 0 28 m of fresh outside air for each 100 000 BTU Hr of rating This heater requires a ...

Страница 5: ... and Ontario Workplaces Reg 833 25 ppm 5000 ppm 3 ppm Reg 833 Canada STEL 15 minutes Reg 833 1 hour WSBC WorkSafe BC OHS Guidelines Part 5 1 and Ontario Workplaces Reg 833 100 ppm 15000 ppm WSBC 30000 ppm Reg 833 1 0 ppm WorkSafeBC 5 0 ppm Reg 833 Ensure that the flow of combustion and ventilation air exchange cannot become obstructed As the building tightens up during the construction phases vent...

Страница 6: ...eset and you can try to light the heater once again TO SHUT DOWN HEATER 1 Tightly close control valve on propane tank s 2 Give the heater a few seconds to burn the gas still left in the hose 3 Turn on off switch to the OFF position 4 Unplug extension cord from power source TO RESTART HEATER NOTE If the safety control stops the flow of gas to the heater the motor will continue to run To restart the...

Страница 7: ...ft replace fan as shown in Figure 7 Tighten setscrew firmly be careful not to overtighten 10 Reconnect lead wires as shown in the Wiring Diagram Figure 8 11 Reassemble base fan guard and base lower IGNITOR The only maintenance necessary for the ignitor is to be sure that the gap between the electrodes is kept between 10 and 15 2 5 3 8 mm The ignitor is accessible through the combustion chamber Sto...

Страница 8: ...ing Instructions and Parts Manual RMC FA300PF If any original wiring as supplied with the heater must be replaced it must be replaced with type AWG105 C wire or its equivalent except as indicated Type SF2 200 SGI 250 C Figure 8 Wiring Diagram NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING E N G L I S H ProFitterTM Propane Construction Heater For Technical Support or Troubleshooting Call 1 877 447...

Страница 9: ...Notes ProFitterTM Operating Instructions and Parts Manual RMC FA300PF NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING For Technical Support or Troubleshooting Call 1 877 447 4768 8 30 am 4 30 pm CST www ghpgroupinc com ...

Страница 10: ...55 56 57 58 24 23 22 12 20 14 13 15 16 17 18 19 21 7 9 10 11 8 26 For Technical Support or Troubleshooting Call 1 877 447 4768 ProFitterTM Dyna GloTM Operating Instructions and Parts Manual 10 ProFitterTM Operating Instructions and Parts Manual RMC FA300PF NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING For Repair Parts call 1 877 447 4768 Please provide following information Model number Serial n...

Страница 11: ...01633 1 34 Power Cord Assembly 2201163 1 35 Switch 2201549 1 36 Solenoid Valve 2315449 1 37 Screw 2001206 2 38 Connector Inlet 2315595 1 39 Fitting 2315596 1 40 Solenoid Valve Bracket 2315594 1 41 Screw 2000416 2 42 Nut 2000384 2 43 Back Pressure Switch 2201594 1 44 Base Lower 2315589 1 45 Screw 2001355 6 46 PCB Assembly 2201181 1 47 Screw 2001445 2 48 Nut 2000231 2 49 Base 2315588 1 50 Plastic Tu...

Страница 12: ...r cord and extension cord for cuts and breaks 2 Be sure that housing is not damaged Make sure there are no obstructions to the fan 3 Straighten blade s to match others 4 Replace motor 1 Check igniter wire Reattach or tighten if loose Check spark module Replace if necessary Check all electrical components 2 Set gap to 0 08 2 mm 3 Replace spark plug 1 If the heaters output is restricted internal tem...

Страница 13: ...how long an implied warranty lasts so the above limitation may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you CLAIMS HANDLED AS FOLLOWS 1 Contact your retailer and explain the problem 2 If the retailer is unable to resolve the problem contact ourCustomer Service Dept detailing th...

Страница 14: ...s SAVE THIS CARD Place Postage Stamp Here GHP Group Inc 8280 Austin Avenue Morton Grove IL 60053 3207 GHP Group Inc 8280 Austin Ave Morton Grove IL 60053 3207 Tel 877 447 4768 www ghpgroupinc com 8280 Austin Avenue Morton Grove IL 6 0 0 5 3 3 2 0 7 Tel 847 324 5900 Fax 847 324 5901 Toll Free 877 GHP Group 8 7 7 4 4 7 4 7 6 8 www ghpgroupinc com GHP GHP Group Inc 6440 W Howard St Niles IL 60714 330...

Отзывы: